{"title":"IKA Milling \u0026 Reactors","description":"\u003cp\u003eBrowse milling \u0026amp; reactors from IKA. Compare the available products below, or return to the complete brand range.\u003c\/p\u003e","products":[{"product_id":"ika-multidrive-basic-m20-successor-package-0010010968","title":"IKA MultiDrive basic M20 Successor Mill Package, 100–120 V","description":"\u003cdiv id=\"bts-ika-multidrive\" style=\"width:100%;box-sizing:border-box;max-width:1400px;margin:0 auto;font-family:Open Sans,sans-serif;font-weight:300;color:#26332C;\"\u003e\n\u003csection style=\"padding:22px;border:1px solid #B9CADA;border-radius:10px;background:#F3F6FA;\"\u003e\u003cp style=\"font-size:.85rem;font-weight:600;letter-spacing:.05em;color:#245B45;\"\u003eIKA MULTIDRIVE BASIC M20 SUCCESSOR PACKAGE • 0010010968 • 100–120 V\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem);font-weight:600;color:#13314E;line-height:1.15;margin:0 0 20px;\"\u003eA modern milling drive. The chamber you need to start.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eChoose a defined laboratory grinding package rather than a drive with its essential vessel missing. IKA catalog \u003cstrong\u003e0010010968\u003c\/strong\u003e combines the \u003cstrong\u003eMultiDrive basic\u003c\/strong\u003e with a reusable \u003cstrong\u003eMI 250-S, 250 mL milling chamber\u003c\/strong\u003e and its standard stainless-steel beater.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eDesigned around impact milling of suitable hard, brittle and dry samples, the package offers a 3,000–20,000 rpm speed range, LED controls, a timer and interval operation. The 100–120 V, 50\/60 Hz US configuration is distinct from other regional order codes.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA identifies it as the successor package for the M 20 mill. That means a different purchasing option, not identical hardware, interchangeable legacy accessories or automatic equivalence for an established analytical method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"IKA MultiDrive basic mill with MI-series chamber mounted, manufacturer package photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-kit.webp?v=1793579480\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-kit.webp?v=1793579480\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-kit.webp?v=1793579480\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-kit.webp?v=1793579480 1000w\" style=\"width:100%;max-width:600px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer photograph used for the package. Order scope is one basic drive and one MI 250-S chamber with standard beater; displayed settings are illustrative.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 150px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e250 mL\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eMaximum useful chamber volume\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 150px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e3,000–20,000 rpm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eVariable drive speed\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 150px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e5 Mohs \/ 7 mm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eStandard-beater hardness \/ impact-feed limits\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 150px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e5 min ON \/ 10 min OFF\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eMaximum run \/ minimum cooling time\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhat is included in the M20 Successor Package?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Included MI 250-S milling chamber shown separately from the drive\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-chamber.webp?v=1793579480\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-chamber.webp?v=1793579480\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-chamber.webp?v=1793579480\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-chamber.webp?v=1793579480 1000w\" style=\"width:100%;max-width:350px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eThe same included chamber shown separately, not a second vessel supplied with the package. Standard stainless-steel beater included.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eOne factory package, not an invented bundle\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eMultiDrive basic drive, in the specified 100–120 V configuration.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eOne MI 250-S sealed-version milling chamber, 250 mL maximum useful volume.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eStandard stainless-steel beater supplied with the chamber.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eThe drive’s documented power cord, USB cable, socket wrench, disassembly tools and cleaning brush.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe vessel instructions also identify the cooling-circuit hose connections supplied with the chamber. An external cooling source, extra vessels, a tungsten-carbide beater, star-shaped cutter and software license are not established as part of this package.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe separately sold basic drive, US catalog 0025002639, does not include a milling vessel. This factory package supplies the specified MI 250-S rather than leaving the chamber selection to a later purchase.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eStart with the standard beater’s actual limits\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eImpact milling, not a universal sample-processing promise\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe included standard stainless-steel beater is specified for feed hardness up to 5 Mohs and impact feed size up to 7 mm. The chamber has a 250 mL maximum useful volume. These are different limits: none establishes a guaranteed batch mass, final particle size or processing time for every material.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA describes dry-grinding applications for suitable hard or brittle materials. The drive instructions give examples such as grain, roasted coffee, seeds, salts and feed materials. Material behavior, moisture, fat content, loading and cooling all affect the result.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFibrous material can require the separately selected star-shaped cutter and an appropriate method. The optional hard-metal beater has different limits; its ratings must not be advertised as the performance of this standard-beater package.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eNot a contamination-free milling claim.\u003c\/strong\u003e The stainless-steel tool and chamber are in contact with the sample. Assess suitability for trace-metal or other contamination-sensitive analysis before choosing the method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Interior of the MI 250-S chamber showing the standard stainless-steel beater\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-chamber_detail.webp?v=1793579480\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-chamber_detail.webp?v=1793579480\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-chamber_detail.webp?v=1793579480\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-chamber_detail.webp?v=1793579480 1000w\" style=\"width:100%;max-width:450px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer view inside the chamber. Tool edges can be sharp; stop, disconnect power and follow the disassembly instructions before handling.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eBasic controls, without Control-model feature confusion\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Close-up of the genuine MultiDrive basic LED control panel from manufacturer photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-controls.webp?v=1793579480\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-controls.webp?v=1793579480\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-controls.webp?v=1793579480\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-controls.webp?v=1793579480 1000w\" style=\"width:100%;max-width:520px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eActual Basic control-panel crop. Display values are illustrative and are not recommended settings for a sample method.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eLED speed and time display, with straightforward operation\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe MultiDrive basic uses a seven-segment LED display and a rotary\/push control for speed and operation. It provides timer\/counter functions and interval operation. The manual lists a Basic interval pattern of 13 seconds running and 2 seconds stopped; do not assume the Control model’s freely adjustable interval settings.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eThis is not MultiDrive control.\u003c\/strong\u003e The Basic drive does not provide the Control model’s weighing function, TFT display, temperature measurement, RFID reader or program\/ramp-control functions. The MI 250-S in this package is also not a temperature-sensing T vessel.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe correct motor figures are 1,000 W rated input and 800 W rated output. Those figures are not interchangeable. The Basic drive’s own technical data and operating manual establish the Basic features used on this page.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCooling jacket does not mean an included chiller\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eIndirect cooling through the chamber wall\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe MI 250-S has connections for a water-cooling circuit, allowing heat to be removed indirectly rather than mixing coolant with the sample. The vessel manual specifies a maximum cooling-circuit pressure of 0.5 bar and a cooling-fluid range of −5 to +40 °C.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe package does not include a recirculating chiller. Select a suitable external cooling arrangement and secure the hoses as instructed; do not connect an unrestricted pressurized supply or treat the jacket as a built-in refrigerator.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manufacturer permits dry-ice cooling only within the applicable drive and vessel instructions, including ventilation and pressure precautions. Liquid-nitrogen cooling is not permitted in the chamber’s technical table.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCooling does not turn the Basic drive into a temperature-controlled system or remove its duty-cycle limit. Temperature-sensitive samples may need shorter runs, a different vessel\/drive configuration or another preparation method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Rear view of the MI 250-S chamber showing its two cooling connections\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-chamber_alt.webp?v=1793579480\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-chamber_alt.webp?v=1793579480\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-chamber_alt.webp?v=1793579480\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-chamber_alt.webp?v=1793579480 1000w\" style=\"width:100%;max-width:350px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer view of the chamber connections. An external cooling source and method-specific tubing arrangement are separate requirements.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eHow to plan a repeatable milling cycle\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1280\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-workflow-phone.webp?v=1793579529\" width=\"720\"\u003e\u003cimg alt=\"Original four-step milling workflow: inspect and select, load and close, grind within limits, cool before handling\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-workflow.webp?v=1793579480\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-workflow.webp?v=1793579480\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-workflow.webp?v=1793579480\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-workflow.webp?v=1793579480 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal planning diagram, not a substitute for installation or safety instructions. Maximum run time is 5 minutes, followed by at least 10 minutes off for cooling.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSet the method around the material, not the maximum dial setting\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eInspect the drive, chamber, lid, seals and beater. Use only undamaged, manufacturer-approved components.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eChoose a suitable feed preparation and charge. Respect the 7 mm impact-feed, 5 Mohs standard-beater and 250 mL useful-volume limits.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eAttach and close the vessel correctly. The manual identifies green status indication as ready for operation; never bypass the closure safety arrangement.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eChoose appropriate speed and time, watching for heat buildup, adhesion or overload. Stay within the maximum 5-minute run limit.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eAllow at least 10 minutes off for cooling. Wait for a complete stop and safe handling temperature before opening; disconnect power for accessory changes and cleaning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFinal granularity depends on the sample, loading and duration. No universal fineness, throughput, recovery or temperature is promised. Trained users should document their own suitable method and read both operating manuals before use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhich MultiDrive configuration do I need?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1320\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-selection-phone.webp?v=1793579529\" width=\"720\"\u003e\u003cimg alt=\"Basic versus Control and M20 replacement guide: this package has Basic and MI 250-S, not Control weighing or sensing; MT 150 and BT 250 require Control\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-selection.webp?v=1793579480\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-selection.webp?v=1793579480\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-selection.webp?v=1793579480\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-selection.webp?v=1793579480 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal selection guide. Separate models and optional vessels are not extra items included with this order.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose this package for defined 250 mL milling\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCatalog 0010010968 supplies the Basic drive plus MI 250-S and standard beater. Choose it when its sample, vessel, control and operating limits suit the method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose Control for the relevant advanced functions\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eWeighing, temperature monitoring and programmable functions belong to the appropriate Control configuration. Temperature monitoring also requires the correct sensing vessel; a drive upgrade alone does not make this non-T chamber measure temperature.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eDo not put MT 150 or BT 250 tubes on Basic\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe drive manual explicitly says the Basic unit does not operate those tubes, even with the TC 1 housing. The Control MT\/BT packages are separate configurations with their own vessels and requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eReview an established M 20 method before changing hardware\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe legacy M 20 uses a fixed 20,000 rpm; MultiDrive basic offers variable speed. Review vessel geometry, tool, loading and method performance rather than treating the successor designation as proof of identical results or accessory interchangeability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eOther formats are separate selections\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eAn optional blending vessel is not in this package\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe MultiDrive platform supports additional functions through separately selected vessels. The Basic drive can be paired with manufacturer-approved blending vessels for suitable mixing\/wet-crushing tasks, but that does not mean such a vessel arrives in this order.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe adjacent manufacturer image illustrates the drive with an optional blending vessel. This package instead includes the MI 250-S chamber. Do not infer that both vessels, a large-volume blender or a dispersing attachment are supplied.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor wet milling, distinguish the sealed S version from an ordinary MI vessel and verify the material and actual supplied version. The vessel manual permits wet work in verified sealed S versions but marks solvents as not suitable. No blanket organic-solvent compatibility or pressure-reactor use is claimed here.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"MultiDrive basic drive with optional blending vessel, not included in the M20 Successor Package\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-drive_alt.webp?v=1793579480\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-drive_alt.webp?v=1793579480\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-drive_alt.webp?v=1793579480\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-drive_alt.webp?v=1793579480 1000w\" style=\"width:100%;max-width:500px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOptional blending setup shown for format comparison only. The blending vessel is not included; the purchased package contains MI 250-S.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eApplication fit and when to choose another method\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eHard or brittle dry samples\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eA suitable use case for the standard beater when feed size and hardness are within the published limits. Grain, suitable seeds, salts and other manufacturer-described sample classes still require method evaluation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSamples sensitive to heating\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eConsider shorter runs, appropriate cooling and a validated preparation sequence. Basic does not measure sample temperature and its chamber is not the sensing T version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSoft, fibrous or high-fat samples\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThese may behave differently from brittle dry feed. A different tool, preparation or vessel may be necessary. Do not assume the standard beater is the right configuration merely because the drive belongs to a versatile platform.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor research laboratory use by trained personnel. This system is not explosion-protected. Do not use it in explosive atmospheres or assume combustible dust, reactive media or unlisted materials are suitable without the manufacturer’s assessment and applicable safety controls. No clinical\/diagnostic or universal food-contact regulatory approval is claimed.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCleaning, wear and useful troubleshooting checks\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eMaterial coats the wall instead of grinding\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eReview whether moisture, fat content, loading or material properties suit the selected method. More speed or a longer run is not automatically the answer, and the duty limit still applies.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eVessel or drive gets hot\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eStop and allow the required cooling period. Check loading, speed and cooling arrangements. Do not treat the Basic display as a sample-temperature measurement or bypass a protective stop.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eResidue or tool wear affects the result\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eClean the chamber manually according to its instructions. Inspect the beater, seals and lid. Worn tools can change performance; material-contact wear must be considered in contamination-sensitive methods.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe chamber is not dishwasher-cleanable. IKA identifies water with surfactant and isopropyl alcohol as approved cleaning agents in the vessel instructions; that does not authorize solvent milling during operation. Protect the lid seal, use appropriate gloves and follow the illustrated disassembly procedure.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor manufacturer technical support, repairs and service, contact IKA. Initiate product return requests through Blue Tiger Scientific under the applicable IKA conditions. The manuals state a 24-month warranty subject to terms and exclusions for wear, misuse and inadequate care; any registration extension depends on the applicable manufacturer terms.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eRelated workflows available from Blue Tiger\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-t-25-digital-ultra-turrax-disperser-drive?variant=53396356563242\" style=\"font-weight:600;color:#245B45;\"\u003eIKA T 25 digital drive for separately configured liquid dispersion\u003c\/a\u003e. A rotor-stator disperser is a different preparation route, and the T 25 requires its own suitable dispersing tool and setup. It is not an accessory included with this mill.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-rv-10-digital-pro-v-c-complete-115v-0010012821?variant=53420242895146\" style=\"font-weight:600;color:#245B45;\"\u003eIKA RV 10 digital pro V-C Complete for a separate solvent-concentration step\u003c\/a\u003e. Consider it only where the broader research method calls for evaporation after an appropriately separate work-up. This link does not establish that organic solvent may be processed in the MI 250-S.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;margin-top:32px;padding-top:20px;\"\u003e\u003cdiv style=\"width:100%;padding:20px 0;font-family:Open Sans,sans-serif;font-weight:300;line-height:1.15;color:#333;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat is included in IKA package 0010010968?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eOne MultiDrive basic drive and one MI 250-S 250 mL milling chamber with a standard stainless-steel beater. The drive’s documented accessories include its power cord, USB cable, wrench, disassembly tools and cleaning brush. No extra blending vessel, chiller, star-shaped cutter or hard-metal beater is established as supplied.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs this an alternative to buying another IKA M 20 mill?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIKA identifies 0010010968 as its M20 Successor Package. It offers a Basic drive with variable 3,000–20,000 rpm and the specified MI 250-S chamber, while the legacy M 20 uses a fixed 20,000 rpm. It is not identical hardware or proof that legacy vessels\/blades or a validated method transfer without review.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes MultiDrive basic include weighing, a TFT screen or temperature monitoring?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The Basic-drive manual specifies LED controls and no weighing function, integrated temperature\/RFID sensing or program-control function. Those are distinctions of appropriate Control configurations. The supplied MI 250-S is not the temperature-sensing T chamber.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eHow large or hard can the sample be with the supplied beater?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe MI 250-S is specified for up to 250 mL useful volume, feed hardness up to 5 Mohs with the standard beater, and impact feed size up to 7 mm. Those are separate limits, not a guarantee for every sample or a fixed permitted batch mass. The optional hard-metal tool’s higher rating is not the rating of this package.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan I run this mill continuously or use a 30-minute cycle?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. MultiDrive basic is limited to a maximum 5 minutes on followed by at least 10 minutes off for cooling. The chamber and material limits also apply. Control-model references to longer vessel-specific operation must not be copied to this Basic package.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs a chiller included, and does the chamber regulate sample temperature?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo chiller is listed in this package. The chamber supports indirect water cooling through its jacket, with maximum circuit pressure 0.5 bar per the manual. Basic and the non-T MI 250-S do not measure or regulate sample temperature. Follow the vessel’s cooling instructions; liquid nitrogen is not permitted.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan I add MT 150 or BT 250 tubes to this Basic drive later?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. IKA’s drive manual explicitly says these tubes require MultiDrive control and do not operate on Basic, even with the TC 1 protective housing. Choose an appropriate Control configuration if that tube workflow is required; those tubes and the housing are not included here.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes the sealed MI 250-S mean I can mill any liquid or solvent?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The manual distinguishes sealed S vessels that can support appropriate wet milling from ordinary MI versions that must not receive liquids. It also marks solvents as not suitable. Verify the actual supplied vessel version and method before wet work. The package is presented here for its manufacturer-described dry-grinding role, not universal solvent or pressure-vessel service.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53420411814186,"sku":"BTS-0010010968","price":5051.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-kit.webp?v=1793579480"},{"product_id":"ika-lr-1000-control-laboratory-reactor-system-115v-0025001992","title":"IKA LR 1000 control 1 L Laboratory Reactor System, 115 V","description":"\u003cdiv id=\"bts-ika-lr1000\" style=\"width:100%;box-sizing:border-box;max-width:1400px;margin:0 auto;font-family:Open Sans,sans-serif;font-weight:300;color:#26332C;\"\u003e\n\u003csection style=\"padding:20px;border:1px solid #B9CADA;border-radius:10px;background:#F3F6FA;\"\u003e\u003cp style=\"font-size:.85rem;font-weight:600;letter-spacing:.04em;color:#245B45;\"\u003eIKA LR 1000 CONTROL SYSTEM • 0025001992 • US 115 V\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem);font-weight:600;color:#13314E;line-height:1.15;margin:0 0 20px;\"\u003eTurn a beaker trial into a controlled formulation workflow.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eBring \u003cstrong\u003eanchor mixing, heating, sample-temperature sensing and process visibility\u003c\/strong\u003e to one compact benchtop. The IKA LR 1000 control System is a 1 L laboratory reactor for developing suitable viscous formulations, including creams and lotions in cosmetic and pharmaceutical research.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUS catalog \u003cstrong\u003e0025001992\u003c\/strong\u003e supplies the Control base, \u003cstrong\u003eLR 1000.3 reactor vessel\u003c\/strong\u003e, anchor stirrer with PEEK scrapers and a PT 100.30 temperature sensor. Its TFT interface adds onboard weighing, relative torque-trend display and a connection for a separately selected pH electrode.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eStart with a defined factory system, then add only the cooling, vacuum or high-shear equipment your method needs. Cooling, vacuum and high-shear equipment are separate selections, not items included with this order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"IKA LR 1000 control laboratory reactor, front view with supplied vessel and anchor-stirring assembly\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115 1000w\" style=\"width:100%;max-width:600px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer photograph. Display readings are illustrative. Order scope follows the supplied-parts checklist; optional external instruments are not included.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e1 L\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eMaximum useful volume\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e10–150 rpm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eAnchor-stirring speed range\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e100,000 mPa·s\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eMaximum published viscosity rating\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e120°C\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eMaximum working temperature of the medium\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection id=\"bts-lr1000-buyer-fit\" style=\"padding:24px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003cp style=\"font-size:.83rem;font-weight:600;letter-spacing:.04em;color:#245B45;margin:0 0 8px;\"\u003eA QUICK BUYING DECISION\u003c\/p\u003e\n\u003ch2 style=\"font-size:1.5rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 14px;\"\u003eIs this the right system for your lab?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 18px;\"\u003eThe strongest reason to choose LR 1000 control is a defined formulation workflow, not simply a higher-priced stirrer. Match the batch, process measurements and supplied equipment to the work you need to do.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:18px;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eDevelop suitable creams, lotions and viscous blends\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0;\"\u003eChoose this 1 L platform when your R\u0026amp;D work calls for anchor mixing and controlled heating of a suitable viscous formulation. Its 300–1,000 mL useful range without a disperser makes the intended batch scale clear before you choose the system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:18px;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eFollow the batch, not just the speed dial\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0;\"\u003eUse the TFT view to follow medium temperature and relative torque changes at constant set speed. Pause heating and stirring to use onboard weighing. Add a suitable pH electrode separately if pH measurement belongs in your method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:18px;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eStart with the core hardware already selected\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0;\"\u003eThe Control base, LR 1000.3 vessel, PEEK-scraper anchor and PT 100.30 sensor are specified together under US order code 0025001992. You can distinguish the core system from optional cooling, vacuum or dispersing equipment instead of budgeting for an undefined collection of parts.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:18px;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eChoose Control for functions you will actually use\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0;\"\u003eControl is the choice when its TFT interface, weighing, relative torque trend and pH connection support your workflow. If those functions are unnecessary, compare Basic instead. Both versions share the stated 1 L maximum volume and 120°C medium limit; Control does not buy a larger vessel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px;padding:16px;border:1px solid #D9C49B;border-radius:8px;background:#FFF9EF;box-sizing:border-box;\"\u003e\n\u003ch3 style=\"font-size:1.05rem;font-weight:600;color:#57482D;margin:0 0 9px;\"\u003eChoose another platform when the limits do not fit\u003c\/h3\u003e\n\u003cp style=\"font-size:.97rem;line-height:1.65;margin:0;\"\u003eNeed less than 300 mL without a disperser, more than 1 L, positive-pressure reaction service or a medium temperature above 120°C? This is not that configuration. With an optional disperser, the separate minimum is 500 mL. For calibrated absolute viscosity, select a suitable viscometer rather than treating torque trend as a viscosity result.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhat comes with the US Control system?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Close-up of the LR 1000 reactor vessel, lid ports and anchor assembly from the manufacturer photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-vessel.webp?v=1793763115\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-vessel.webp?v=1793763115\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-vessel.webp?v=1793763115\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-vessel.webp?v=1793763115 1000w\" style=\"width:100%;max-width:440px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eActual photograph detail, not a second vessel. The Control vessel uses FFKM O-ring material and PEEK scrapers; suitability still depends on the medium and conditions.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThe vessel, stirrer and temperature sensor are part of the system\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eLR 1000 control base, US 115 V, 50\/60 Hz.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eLR 1000.3 laboratory reactor vessel.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eLR 1000.10 anchor stirrer with PEEK scrapers, listed in the current US system scope.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003ePT 100.30 temperature sensor and the supplied sensor receptacle, listed as LR 1000.62 in the current US order scope.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eSilentstream, support rod and two hose connectors.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eUSB A to Micro-B cable, 2 m. The operating manual also identifies a mains cable and tool kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eNot listed as supplied:\u003c\/strong\u003e a pH electrode, T 25 disperser and reactor-specific dispersing tool, external chiller or other cooling supply, vacuum pump, reflux condenser or labworldsoft software license. Select those separately when the application needs them.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manual covers both Basic and Control and includes shared installation illustrations. Use the Control column and the actual supplied components; a shared drawing is not proof that every illustrated accessory is in this package.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eMix viscous formulations with a defined batch window\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eAnchor mixing for suitable viscous media\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe supplied anchor and PEEK scrapers support mixing within the 10–150 rpm range. The published maximum viscosity is 100,000 mPa·s. This is a selection limit, not a promise of identical performance at every fill, speed, temperature or formulation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWork at a useful laboratory scale\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manufacturer specifies 300–1,000 mL without a dispersing tool and 500–1,000 mL when an appropriate dispersing tool is fitted. Do not treat the 1 L maximum as a universal recommended charge or assume it is a micro-volume reactor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose chemistry against the contact materials\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe Control configuration includes stainless steel, borosilicate glass 3.3, PTFE, PEEK and FFKM in the documented wetted assembly. Check chemical, seal and temperature compatibility for the actual formulation; the material list is not blanket solvent approval.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSee the process, not just the speed setting\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Genuine detail of the LR 1000 control TFT display and rotary controls\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-controls.webp?v=1793763115\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-controls.webp?v=1793763115\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-controls.webp?v=1793763115\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-controls.webp?v=1793763115 1000w\" style=\"width:100%;max-width:440px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eA crop of the real manufacturer photograph. Readings are illustrative, not a recipe, calibration reference or recommended operating settings.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eTFT operation with useful formulation measurements\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eControl brings the main operating values together on a color TFT display, with rotary\/push controls and an intuitive menu. Follow sample temperature and stirring settings, use the integrated weighing function and observe relative torque changes during your method.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eWeighing:\u003c\/strong\u003e the specified range is 3–2,000 g with 1 g resolution. Heating and stirring must be deactivated for weighing, as the manual requires. It can simplify formulation additions in the reactor, but it does not replace an analytical balance when your method requires finer or certified mass measurement.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eTorque trend:\u003c\/strong\u003e this is a relative process indicator. Use a constant set speed for torque-trend measurement; the manual says it cannot be combined with intermittent mode. A change may help you see how a formulation develops under consistent conditions, but the reactor does not report a calibrated absolute viscosity in mPa·s.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003epH:\u003c\/strong\u003e the integrated BNC connection and TFT display support pH measurement with a suitable separately selected electrode. A probe is not in the listed standard delivery. Calibrate the selected electrode before measurement; the manual requires an inserted temperature sensor for calibration. Chemical compatibility and the applicable probe instructions still matter.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUSB and RS 232 support a separately configured PC workflow. IKA labworldsoft is optional software, not a license included with this system. No automatic electronic-record, audit-trail or regulatory-compliance claim is made.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eHeat the medium within its working-temperature limit\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003e120°C working temperature is not the same as the heater rating\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe integrated heating block supplies heat through the vessel base. The external PT 100 temperature sensor measures the medium so heating can be controlled around the process temperature rather than an assumed hotplate setting.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eThe maximum working temperature of the medium is 120°C.\u003c\/strong\u003e A separate 180°C heating-block specification appears in the manufacturer’s data; it is not permission to operate the formulation at 180°C.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manual requires the external temperature sensor to remain immersed in the medium, with at least 20 mm insertion depth. Set the adjustable safety circuit appropriately for the medium and method, and account for residual heat before handling or removing the vessel.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe equipment shuts off stirring and heating when the vessel or lid is removed during operation. These protections do not replace operator supervision, a suitable risk assessment or the full safety instructions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"LR 1000 control with its vessel seated on the integrated heated base\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115 1000w\" style=\"width:100%;max-width:500px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eHeating is integrated in the base. No external hotplate is required for the specified heating function, and no external cooling instrument is supplied.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eAdd external cooling when the method calls for it\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Manufacturer rear view of the LR 1000 control showing cooling and electrical connections\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-rear.webp?v=1793763115\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-rear.webp?v=1793763115\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-rear.webp?v=1793763115\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-rear.webp?v=1793763115 1000w\" style=\"width:100%;max-width:600px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eRear-view photograph. Cooling connections serve the base’s cooling coils; this is not an included chiller or a general-purpose pressurized jacket circuit.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCooling connections are built in. The cooling supply is separate.\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFlow-through cooling uses integrated cooling coils in the base. Connect an appropriate external cooling arrangement when your method needs controlled heat removal or a cooling step. The system is not supplied with a recirculating chiller.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manufacturer lists a \u003cstrong\u003e3°C minimum cooling-medium temperature\u003c\/strong\u003e and \u003cstrong\u003e1 bar maximum permissible cooling-medium pressure\u003c\/strong\u003e. The operating instructions also require an unpressurized cooling arrangement. Do not connect an unrestricted pressurized supply or treat the 1 bar limit as a recommendation to pressurize the circuit.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSecure the hoses, provide the specified outlet\/drain arrangement and follow the manual’s connection instructions. The optional MV1 valve is installed only on the cooling inlet and must be selected and connected correctly.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor planning, separate the desired sample temperature from cooling-medium temperature, flow and available cooling capacity. A compatible connection alone does not guarantee the required cooling time for every batch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA practical formulation workflow\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1260\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-workflow_phone.webp?v=1793763118\" width=\"720\"\u003e\u003cimg alt=\"Original LR 1000 formulation planning guide: define the batch, mix and control heat, follow process values, cool and document\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-workflow.webp?v=1793763115\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-workflow.webp?v=1793763115\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-workflow.webp?v=1793763115\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-workflow.webp?v=1793763115 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal planning guide. With an optional disperser, use the separate 500–1,000 mL useful-volume range. This diagram does not replace installation or safety instructions.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eBuild the method around the batch and its limits\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eDefine the medium, target batch, contact-material compatibility and required mixing or dispersing route.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eInspect the glass vessel, lid, seals, anchor and temperature sensor. Install and lock the equipment as the manual directs.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eUse an appropriate charge and keep the PT 100 sensor immersed. Start stirring at a suitable low setting and adjust within the method’s limits.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eControl heat against the measured medium temperature. Follow relative torque and use weighing or a separately configured pH measurement where relevant.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eUse the selected cooling arrangement when required. Stop, allow safe handling temperatures, isolate power for cleaning and record the method before changing the next batch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eA visible torque change can be a useful process observation, but it is not proof of a particular viscosity, emulsion quality or validated endpoint. Establish and document your own acceptance criteria.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhich LR 1000 setup should I choose?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1320\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-selection_phone.webp?v=1793763118\" width=\"720\"\u003e\u003cimg alt=\"Original selection guide distinguishing this Control system from optional disperser, cooling, vacuum and pH additions\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-selection.webp?v=1793763115\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-selection.webp?v=1793763115\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-selection.webp?v=1793763115\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-selection.webp?v=1793763115 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eThis order is the 115 V Control system, not a bundle with every optional instrument. Separate hardware shown or described in family literature is not automatically supplied.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose Control for additional process visibility\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThis system adds the TFT interface, weighing function, relative torque-trend display, pH-electrode connection and MV1 control interface. Choose it when these functions contribute to your formulation workflow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eConsider Basic when those extra functions are unnecessary\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe Basic and Control manual lists the same 1 L maximum volume, 10–150 rpm speed range and 120°C medium limit. Basic uses LED displays and does not supply Control’s weighing, pH or torque-trend functions. Control is not a higher-volume reactor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eAdd high-shear dispersion as a separate configuration\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA lists the T 25 digital with reactor-specific S 25 KV-25 F or S 25 KV-25 G elements in the manual. The drive, appropriate tool and required fitting must be selected together. A generic T 25 shaft is not automatically the correct reactor tool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eVacuum-capable does not mean pressure-reactor service\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe LR 1000 is designed for vacuum operation down to \u003cstrong\u003e25 mbar\u003c\/strong\u003e under the applicable equipment and process conditions. A suitable external vacuum arrangement is a separate selection; no vacuum pump is included in this system.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eIt is not designed for overpressure operation.\u003c\/strong\u003e At normal pressure, the reactor must remain appropriately ventilated to prevent pressure buildup. Volatile processes may also require a suitable condenser, containment and laboratory ventilation selected for the method.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eDo not infer that the cooling-circuit pressure limit is an allowable reaction-vessel pressure. The system is not explosion-protected, and it must not be operated in an explosive atmosphere. Trained staff must assess hazardous media and follow the complete operating instructions.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCleaning and care that support the next batch\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eLet the equipment cool safely\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe heating block, vessel and lid can remain hot after the process stops. Stop stirring and isolate the electrical supply before accessory changes or cleaning, following the specified safe-removal procedure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eInspect the wetted assembly\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCheck the glass for damage and inspect the scraper, O-rings, shaft seal and connections. Wear and residue can affect both operation and process observations. Select cleaning agents that suit the actual materials and contamination risks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eProtect the electrical base\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eDo not immerse the drive or wash it as if it were an empty glass vessel. The manual identifies product-contacting components as suitable for laboratory dishwashers, while electrical equipment and handles must not be immersed. Follow the separate component and cleaning-agent instructions; this is not an autoclave or sterilization claim.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor product return requests, start with Blue Tiger Scientific. IKA handles manufacturer technical support, warranty assessment, calibration where applicable and repairs under its terms. The operating manual states a 24-month warranty, with exclusions including wear, improper use and insufficient care.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eBuild out the workflow selectively\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eCompatible accessory:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-t-25-digital-ultra-turrax-disperser-drive?variant=53396356563242\" style=\"font-weight:600;color:#245B45;\"\u003eIKA T 25 digital drive, US 100–120 V\u003c\/a\u003e. IKA lists this drive as a reactor accessory. It is drive-only: select the reactor-specific S 25 KV tool and required mounting\/fitting separately. The S 25 N-18 G tool sold for other T 25 work is not established here as the reactor tool.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-multidrive-basic-m20-successor-package-0010010968?variant=53420411814186\" style=\"font-weight:600;color:#245B45;\"\u003eMultiDrive basic M20 Successor Package for a separate dry-sample preparation step\u003c\/a\u003e. Use only when its specified dry-grinding method and sample limits fit the broader workflow; this is not a reactor attachment or permission for solvent milling.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-rv-10-digital-pro-v-c-complete-115v-0010012821?variant=53420242895146\" style=\"font-weight:600;color:#245B45;\"\u003eRV 10 digital pro V-C Complete for separate rotary evaporation\u003c\/a\u003e. This is a distinct concentration\/solvent-removal system, not a vacuum-pump accessory included with the LR 1000.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"bts-lr1000-purchase-guide\" style=\"padding:22px;margin:24px 0;border:1px solid #B7D0BF;border-radius:10px;background:#F1F7F3;box-sizing:border-box;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 14px;\"\u003eReady to specify your LR 1000 control?\u003c\/h2\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;color:#13314E;margin:0 0 10px;\"\u003eOrdering the standard 115 V system\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 16px;\"\u003eChoose catalog \u003cstrong\u003e0025001992\u003c\/strong\u003e when the supplied vessel, scraper anchor and temperature-sensing setup match your method. Review the included-parts checklist and the delivery options shown with your order. Optional external instruments are not included in the standard system.\u003c\/p\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;color:#13314E;margin:0 0 10px;\"\u003eNeed options or procurement confirmation?\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eTell Blue Tiger your target batch volume, formulation type and whether you need dispersion, cooling, vacuum or pH measurement. Ask us to confirm the order scope, request current manufacturer availability and dispatch information, and coordinate any manufacturer application questions before a time-critical purchase.\u003c\/p\u003e\n\u003ca href=\"https:\/\/bluetigerscientific.com\/pages\/contact\" style=\"display:inline-block;max-width:100%;padding:12px 16px;box-sizing:border-box;border-radius:6px;background:#245B45;color:white;text-decoration:none;font-size:1rem;font-weight:600;line-height:1.4;\"\u003eAsk about options or availability\u003c\/a\u003e\u003cp style=\"font-size:.9rem;line-height:1.6;margin:12px 0 0;color:#526158;\"\u003eMention LR 1000 control and catalog 0025001992. Manufacturer stock and dispatch are confirmed separately. The checkout weight allowance is provisional, and automated arrival dates are not a confirmed supplier lead time.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;margin-top:30px;padding-top:20px;\"\u003e\u003cdiv style=\"width:100%;padding:18px 0;font-family:Open Sans,sans-serif;font-weight:300;line-height:1.15;color:#333;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat is included with IKA LR 1000 control System 0025001992?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe US 115 V system includes the Control base, LR 1000.3 reactor vessel, LR 1000.10 anchor stirrer with PEEK scrapers, PT 100.30 sensor and supplied receptacle, Silentstream, support rod, two hose connectors and a USB cable. The manual also identifies the mains cable and tool kit. A pH electrode, disperser, external chiller, vacuum pump and labworldsoft software license are separate selections.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhy choose LR 1000 control rather than LR 1000 basic?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eChoose Control for its TFT operation, integrated weighing, pH-electrode connection, relative torque-trend display and MV1 valve interface. Both versions share the manual’s 1 L maximum useful volume, 10–150 rpm range and 120°C medium limit. Control adds instrumentation and workflow functions, not a larger reactor capacity.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eHow small a batch can I run in the LR 1000 control?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIKA specifies 300–1,000 mL without a dispersing tool and 500–1,000 mL with an appropriate dispersing tool. For 0025001992, choose the charge against the installed configuration and keep the temperature sensor immersed at least 20 mm as the manual requires. Do not assume the 1 L system supports arbitrary micro-volume batches.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan I operate the formulation at 180°C?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The maximum working temperature of the medium is 120°C. The separate 180°C figure is a heating-block specification, not an allowable 180°C sample temperature. Follow the medium limit, immersed sensor requirement, material compatibility and adjustable safety-circuit instructions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes the 100,000 mPa·s rating mean it measures viscosity?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The LR 1000 control has a maximum published viscosity rating of 100,000 mPa·s and a relative torque-trend display. The display indicates changes under the method’s conditions; it is not a calibrated absolute viscosity reading or a substitute for a suitable viscometer. Performance still depends on the formulation, charge, stirrer and operating conditions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs a chiller included, and can I connect ordinary pressurized tap water?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eA chiller is not included. Cooling uses the base’s integrated coils and a separately selected supply. The data lists a 3°C minimum cooling-medium temperature and 1 bar maximum permissible cooling-medium pressure; the manual also requires an unpressurized cooling arrangement. Do not connect an unrestricted pressurized supply. Follow the inlet, outlet and hose instructions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan the LR 1000 control be used under vacuum or positive pressure?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIt is designed for vacuum operation down to 25 mbar with an appropriate separately selected setup. It is not designed for overpressure use. At normal pressure, the reactor must be appropriately ventilated to prevent pressure buildup. Cooling-circuit pressure is not a reaction-vessel pressure rating. No vacuum pump is included in 0025001992.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan I add a T 25 digital disperser, and will any S 25 tool fit?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIKA lists T 25 digital as an accessory, and the reactor manual identifies S 25 KV-25 F and S 25 KV-25 G dispersing elements. Select the correct drive, reactor-specific tool and fitting together. The generic S 25 N-18 G sold for other T 25 work must not be assumed to fit this reactor. Dispersion requires the separate 500–1,000 mL useful-volume range.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53447374733610,"sku":"BTS-0025001992","price":18133.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115"},{"product_id":"ika-lr-1000-basic-laboratory-reactor-system-0020119961","title":"IKA LR 1000 basic 1 L Laboratory Reactor System, US 100–115 V","description":"\u003cdiv id=\"bts-ika-lr1000-basic\" style=\"width:100%;box-sizing:border-box;max-width:1400px;margin:0 auto;font-family:Open Sans,sans-serif;font-weight:300;color:#26332C;\"\u003e\n\u003csection style=\"padding:20px;border:1px solid #B9CADA;border-radius:10px;background:#F3F6FA;\"\u003e\u003cp style=\"font-size:.85rem;font-weight:600;letter-spacing:.04em;color:#245B45;\"\u003eIKA LR 1000 BASIC SYSTEM • 0020119961 • US 100–115 V\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem);font-weight:600;color:#13314E;line-height:1.15;margin:0 0 20px;\"\u003eA defined 1 L mixing-and-heating platform. Straightforward LED operation.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eGive suitable formulation trials a specified vessel, anchor stirrer and immersed temperature sensor instead of treating every run as an improvised beaker setup. The \u003cstrong\u003eIKA LR 1000 basic System\u003c\/strong\u003e brings bottom heating and 10–150 rpm anchor mixing together for laboratory-scale chemical processes and suitable creams, lotions and other viscous formulations.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUS catalog \u003cstrong\u003e0020119961\u003c\/strong\u003e includes the Basic base, \u003cstrong\u003eLR 1000.1 vessel\u003c\/strong\u003e, \u003cstrong\u003eLR 1000.11 anchor stirrer\u003c\/strong\u003e, PT 100.30 temperature sensor and LR 1000.61 sensor receptacle. Its seven-segment LED interface keeps the core operating values in view.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eChoose Basic when those core functions meet your method. If onboard weighing, a pH-electrode connection or relative torque-trend display is a requirement, compare Control before you order. Basic does not acquire those hardware functions simply by adding software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Manufacturer front view of the IKA LR 1000 basic System with LED controls\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-system.webp?v=1793768533\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-system.webp?v=1793768533\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-system.webp?v=1793768533\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-system.webp?v=1793768533 1000w\" style=\"width:100%;max-width:560px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eCurrent manufacturer illustration for Basic. Readings are illustrative; the current US supplied-parts checklist defines the order, not every detail in a family photograph.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e1 L\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eMaximum useful volume\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e10–150 rpm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eVariable anchor-stirring speed\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e120°C\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eMaximum working temperature of the medium\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003eLED controls\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eBasic operation, not the Control TFT interface\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection id=\"bts-basic-buyer-fit\" style=\"padding:24px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003cp style=\"font-size:.83rem;font-weight:600;letter-spacing:.04em;color:#245B45;margin:0 0 8px;\"\u003eA QUICK BUYING DECISION\u003c\/p\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eIs Basic the right system for your lab?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;padding:18px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eA fit for suitable viscous formulation R\u0026amp;D\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eConsider this platform when your work needs anchor mixing and controlled heating in the 300–1,000 mL range without a dispersing tool. Suitable cosmetic and pharmaceutical development work can include cream or lotion trials, provided the material, method and safety limits fit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;padding:18px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eChoose core functions without unused instrumentation\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eBasic makes sense when LED operation, temperature control with the supplied sensor and timed stirring are the functions you need. It does not include Control’s weighing, pH connection or relative torque-trend display.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;padding:18px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eKnow which core parts arrive together\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe factory order specifies the Basic base, LR 1000.1 vessel, LR 1000.11 anchor and PT 100.30 sensing hardware. You can separate the core system from an optional disperser, cooling source or vacuum arrangement before planning the full method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;padding:18px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eKeep a clear upgrade decision\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCompare the linked Control system when its added measurement and interface functions have a purpose in your process. Both versions share the published 1 L capacity and 120°C medium limit, but their supplied vessels, anchors and seal details are not identical.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding:16px;margin-top:16px;border:1px solid #D9C49B;border-radius:8px;background:#FFF9EF;box-sizing:border-box;\"\u003e\n\u003cstrong\u003eChoose another platform when the limits do not fit.\u003c\/strong\u003e\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThis is not a micro-volume, greater-than-1 L, positive-pressure or above-120°C sample-temperature configuration. With a suitable optional disperser, the useful-volume minimum is 500 mL. A viscometer is a separate instrument: Basic does not measure absolute viscosity.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhat is included in US system 0020119961?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Genuine detail of the Basic reactor vessel and lid from IKA’s manufacturer photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-vessel.webp?v=1793768533\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-vessel.webp?v=1793768533\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-vessel.webp?v=1793768533\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-vessel.webp?v=1793768533 1000w\" style=\"width:100%;max-width:430px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eThe supplied vessel is LR 1000.1. Do not substitute Control’s LR 1000.3 or infer an included disperser from a port or illustration.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA manufacturer-defined system, not a collection of assumed extras\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eLR 1000 basic base in the specified US 100–115 V, 50\/60 Hz version.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eLR 1000.1 laboratory reactor vessel.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eLR 1000.11 anchor stirrer.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003ePT 100.30 temperature sensor and LR 1000.61 sensor receptacle.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eSupport rod for securing approved accessories.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eTwo hose connectors for cooling connections.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eThe Basic operating-manual scope also identifies the mains cable, tool kit, instructions and warranty card.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eNot listed as included:\u003c\/strong\u003e an external chiller or other cooling supply, vacuum pump, T 25 disperser, reactor-specific dispersing element and fitting, reflux condenser or labworldsoft software license. A USB cable is listed in the manual’s Control delivery column, not the Basic column; it is not promised with this Basic order.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe Basic order lists LR 1000.11, not Control’s LR 1000.10 anchor with PEEK scrapers. Select from the actual US scope rather than importing the Control package’s scraper or FFKM-vessel claims.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSet the method around the batch, not only the dial\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eUse the specified volume window\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe useful-volume range is 300–1,000 mL without a dispersing tool and 500–1,000 mL with an appropriate tool. These are configuration limits, not permission to run an arbitrary charge, leave the sensor uncovered or fill every formulation to the maximum.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eMatch the material to anchor mixing\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe maximum published viscosity is 100,000 mPa·s. Batch composition, temperature, loading and the installed tool still affect performance. The rating is not a measured viscosity output, a guarantee at every speed or a promise of a particular emulsion result.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCheck the actual wetted assembly\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manual identifies stainless steel including 316L\/316Ti, borosilicate glass 3.3 and PTFE in the assembly, with FKM O-rings for LR 1000.1. Check compatibility against the actual supplied components, reagents and conditions; no blanket chemical compatibility is claimed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eLED operation with the values that matter for Basic\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Actual LR 1000 basic seven-segment LED control panel detail\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-controls.webp?v=1793768533\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-controls.webp?v=1793768533\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-controls.webp?v=1793768533\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-controls.webp?v=1793768533 1000w\" style=\"width:100%;max-width:410px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eGenuine crop of the Basic photograph, not a fabricated display. Values shown are illustrative, not recommended settings for a formulation.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSet speed, follow temperature and time the operation\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe seven-segment LED interface displays the core operating values and uses rotary controls for adjustment. Stirring speed is adjustable from 10 to 150 rpm in 1 rpm increments, with a published ±5 rpm deviation. The timer helps define a repeatable run sequence.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eAn external PT 100.30 sensor is supplied for measuring the medium. Basic supports temperature setting in 1 K increments and a stated 0.1 K temperature-measurement resolution. Those two figures describe different functions.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eBasic is not Control.\u003c\/strong\u003e It has no integrated weighing function, pH-electrode interface, relative torque-trend display or MV1 valve-control interface. Use separate appropriate instruments when the method needs those measurements, or choose the Control system for its documented functions.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUSB and RS 232 interfaces support a separately configured PC workflow under the manufacturer’s instructions. Optional software does not turn Basic into Control, and a labworldsoft license is not listed as part of this system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eControl the medium temperature, not an assumed hotplate temperature\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThe medium limit is 120°C, not 180°C\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe integrated heating block transfers heat through the vessel bottom. Control against the supplied sensor’s medium measurement so the process is based on the sample temperature, not only the heater setting.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eMaximum working temperature of the medium: 120°C.\u003c\/strong\u003e IKA’s separate 180°C heating-temperature figure refers to the heating block and does not authorize operating the formulation at 180°C.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eKeep the external temperature sensor immersed at least 20 mm, as the operating manual requires. Select a suitable safety-circuit setting for the medium and the method, account for residual heat and keep the vessel and lid correctly secured.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe system switches off heating and stirring when the vessel or lid is removed during operation. Replace and lock the components and follow the specified restart procedure; a safety cutout is not a substitute for trained supervision.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Detail of the Basic vessel seated on the heated base\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-base.webp?v=1793768533\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-base.webp?v=1793768533\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-base.webp?v=1793768533\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-base.webp?v=1793768533 1000w\" style=\"width:100%;max-width:450px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer-photo detail of the base and lower vessel. The internal heating block and cooling coils are not exposed in this photograph.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCooling is a separate utility choice\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eLR 1000 basic provides flow-through cooling through coils in the base. An external cooling source is not included. Choose an appropriate arrangement for the desired heat-removal duty, sample and timing rather than treating the reactor as a refrigerated instrument.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eRespect both the data limit and the setup instruction\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manufacturer states a 3°C minimum cooling-medium temperature and 1 bar maximum permissible cooling-medium pressure. The operating manual also requires an unpressurized cooling arrangement. Do not interpret the limit as approval for an unrestricted pressurized supply.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eConnect for cooling, not external heating\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSecure the inlet\/outlet hoses, provide the specified return or drain arrangement and follow the manufacturer’s connection procedure. The connections are for cooling only, not a general-purpose external heating jacket.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eDo not add Control-only valve functions by assumption\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe Basic model does not provide Control’s MV1 valve interface. Plan any separate cooling equipment and control arrangement against the actual Basic configuration; a valve and automated cooling package are not supplied here.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA practical Basic formulation workflow\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1260\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-workflow_phone.webp?v=1793768536\" width=\"720\"\u003e\u003cimg alt=\"Original Basic workflow guide: select a suitable batch, anchor mix, follow medium temperature, cool and document\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-workflow.webp?v=1793768533\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-workflow.webp?v=1793768533\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-workflow.webp?v=1793768533\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-workflow.webp?v=1793768533 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal planning guide. If adding a compatible disperser, use the separate 500–1,000 mL range. Follow the full installation and safety instructions.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eGive each trial a defined starting point\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eChoose suitable media, batch volume and mixing conditions, including the actual seal and material compatibility.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eInspect and correctly install the vessel, lid, anchor and PT 100 sensor. Keep the medium within the applicable fill range and the probe immersed.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eStart at a suitable low speed and adjust within the 10–150 rpm range; control heating against measured medium temperature.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eUse the separately selected cooling arrangement when required and document the operating conditions and observations.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eStop, allow safe handling temperatures and isolate the electrical supply before changes or cleaning, as the manual directs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eBasic does not tell you that an emulsion has reached a validated endpoint. Use appropriate separate measurements and your own method criteria instead of assuming a timed run or maximum speed proves product quality.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eBasic or Control: choose the functions, then verify the hardware\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1320\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-selection_phone.webp?v=1793768536\" width=\"720\"\u003e\u003cimg alt=\"Original LR 1000 Basic versus Control selection guide and separate-equipment reminder\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-selection.webp?v=1793768533\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-selection.webp?v=1793768533\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-selection.webp?v=1793768533\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-selection.webp?v=1793768533 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eThis order is Basic with LR 1000.1 and LR 1000.11. Control and external instruments are separate products, not extra equipment included here.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose this Basic system for its core workflow\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eA defined 1 L anchor-stirring and heating platform, LED operation and PT 100.30 sensing. Choose it when these functions and the actual Basic materials and ports suit the method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose Control when the added instrumentation matters\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eControl provides the TFT interface, weighing, pH-electrode connection and relative torque-trend function. Its LR 1000.3 vessel and documented supplied hardware also differ; do not treat the two packages as identical except for the screen.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eNeither system includes every external instrument\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCooling, vacuum and high-shear dispersion require separately selected equipment. A pH connection is not an included electrode, and a compatible T 25 drive still needs the correct reactor tool and fitting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eVacuum use is not pressure-reaction service\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe specified attainable vacuum is 25 mbar with an appropriate separately selected vacuum arrangement. No vacuum pump is listed in this Basic system’s current US scope. Follow the actual supplied vessel and lid configuration; a port or a drawing is not proof that every vacuum accessory is supplied.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eThe LR 1000 is not designed for overpressure.\u003c\/strong\u003e At normal pressure, keep the reactor appropriately ventilated to prevent pressure buildup. Volatile processes can require a suitable lid-mounted condenser and laboratory ventilation selected for the application.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe cooling-circuit pressure limit is not a reaction-vessel pressure rating. Do not operate in an explosive atmosphere, bypass the vessel\/lid protections or process media that can react dangerously to energy input. Use only trained staff and appropriate process-specific safeguards.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eClean the components for the next trial\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSeparate the vessel-cleaning task from the electrical base\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eStop operation, allow safe handling temperatures and disconnect mains before cleaning. The manual identifies product-contacting components as suitable for laboratory dishwashers, but electrical equipment and handles must not be immersed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eUse the specified cleaning-agent limits\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manual identifies water containing surfactant and isopropyl alcohol as approved cleaning agents. Follow its cleaning\/disinfection pH 5–8 restriction and exclusions for corrosive agents. Cleaning permission is not blanket approval to process the same chemical in a reaction.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eInspect the glass, seals and stirrer\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCheck for damaged glass, residue, seal degradation and wear before the next run. Basic’s LR 1000.1 O-ring material is FKM; do not assume Control’s FFKM seal claim. Consult IKA before unlisted cleaning or decontamination methods.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eStart product return requests through Blue Tiger Scientific. IKA handles manufacturer technical support, warranty assessment, calibration where applicable and repairs under its terms. The operating manual states a 24-month warranty subject to conditions and exclusions including wear, improper use and insufficient care.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSelect the next step in your workflow\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eAlternative model:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-lr-1000-control-laboratory-reactor-system-115v-0025001992?variant=53447374733610\" style=\"font-weight:600;color:#245B45;\"\u003eLR 1000 control System, US 115 V\u003c\/a\u003e for the documented TFT, weighing, pH-connection and torque-trend functions. Compare actual vessel, anchor and seal details before choosing; Control is not a larger-capacity version.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eCompatible accessory:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-t-25-digital-ultra-turrax-disperser-drive?variant=53396356563242\" style=\"font-weight:600;color:#245B45;\"\u003eT 25 digital drive for a separately configured reactor-dispersion setup\u003c\/a\u003e. IKA’s reactor manual identifies S 25 KV-25 F\/G tools; select the correct tool and fitting together. The drive-only page does not supply those automatically, and S 25 N-18 G is not established here as the reactor tool.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-rv-10-digital-pro-v-c-complete-115v-0010012821?variant=53420242895146\" style=\"font-weight:600;color:#245B45;\"\u003eRV 10 digital pro V-C Complete for separate rotary evaporation\u003c\/a\u003e. It is a different solvent-removal\/concentration system, not a pump or other accessory included with this reactor.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"bts-basic-purchase-guide\" style=\"padding:22px;margin:24px 0;border:1px solid #B7D0BF;border-radius:10px;background:#F1F7F3;box-sizing:border-box;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eReady to specify the Basic system?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eOrdering the standard US setup:\u003c\/strong\u003e choose catalog 0020119961 when the LR 1000.1 vessel, LR 1000.11 anchor and supplied temperature-sensing hardware match the method. Review the included-parts checklist and the delivery options shown with your order.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eNeed options or procurement confirmation?\u003c\/strong\u003e Tell Blue Tiger the target batch, material and whether you need dispersion, cooling or vacuum. Ask us to confirm order scope, request current manufacturer availability and dispatch information, and coordinate manufacturer application questions before a time-critical purchase.\u003c\/p\u003e\n\u003ca href=\"https:\/\/bluetigerscientific.com\/pages\/contact\" style=\"display:inline-block;max-width:100%;padding:12px 16px;box-sizing:border-box;border-radius:6px;background:#245B45;color:white;text-decoration:none;font-size:1rem;font-weight:600;line-height:1.4;\"\u003eAsk about options or availability\u003c\/a\u003e\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eMention LR 1000 basic and catalog 0020119961. Manufacturer stock and dispatch are confirmed separately. The checkout weight allowance is provisional; automated arrival dates are not a confirmed supplier lead time.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;margin-top:30px;padding-top:20px;\"\u003e\u003cdiv style=\"width:100%;padding:18px 0;font-family:Open Sans,sans-serif;font-weight:300;line-height:1.15;color:#333;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs LR 1000 basic suitable for cream or lotion formulation trials?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIKA describes the system for laboratory mixing and chemical-process development, particularly in cosmetic and pharmaceutical applications. For a suitable cream, lotion or other viscous formulation, check the actual medium, seals, temperature, useful-volume range and mixing needs. A 100,000 mPa·s rating is not a guarantee of a particular emulsion quality or permission for every ingredient.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat is included with US IKA system 0020119961?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe current US scope lists the Basic base, LR 1000.1 vessel, LR 1000.11 anchor stirrer, PT 100.30 sensor, LR 1000.61 receptacle, support rod and two hose connectors. The Basic manual also identifies the mains cable, tool kit and documentation. External cooling, a vacuum pump, T 25\/reactor tool\/fitting, condenser and labworldsoft license are not listed as supplied.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat do I give up by choosing Basic rather than Control?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eBasic uses LED operation and does not provide Control’s TFT interface, weighing function, pH-electrode connection, relative torque-trend display or MV1 valve-control interface. Both versions share a 1 L maximum useful volume, 10–150 rpm speed range and 120°C medium limit in the manual. The vessel, anchor and seal scope differ; software does not add the missing Control hardware functions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat is the minimum batch size, with or without a disperser?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe manufacturer specifies 300–1,000 mL without a dispersing tool and 500–1,000 mL with an appropriate optional tool. Keep the supplied temperature sensor immersed at least 20 mm and follow the configuration’s other limits. Do not assume the 1 L system supports arbitrary micro-volume batches or that 1 L is always the recommended charge.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes the 180°C heater specification allow 180°C formulations?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The maximum working temperature of the medium is 120°C. The separate 180°C heating-temperature figure refers to the heating block, not the allowed sample temperature. Use the immersed sensor, suitable safety-circuit setting, compatible materials and the complete operating instructions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs a chiller included, and how is cooling connected?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eA chiller is not included. Cooling uses coils in the base and an appropriately selected external source. The published coolant limits are a 3°C minimum temperature and 1 bar maximum permissible pressure; the manual also requires an unpressurized cooling arrangement. Secure hoses and follow the inlet\/outlet instructions. Basic does not include Control’s MV1 valve interface.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan the Basic reactor be used under vacuum or positive pressure?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe specified attainable vacuum is 25 mbar with a suitable separately selected arrangement. A vacuum pump is not in the Basic scope. The system is not designed for overpressure, and normal-pressure operation requires appropriate ventilation to prevent buildup. Do not confuse the cooling-circuit pressure limit with a reaction-vessel pressure rating.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan I use a T 25 digital drive and the S 25 N-18 G tool with this reactor?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIKA names T 25 digital as an accessory, but the reactor manual identifies S 25 KV-25 F and S 25 KV-25 G dispersing elements. Select the appropriate drive, reactor-specific tool and fitting together; do not assume the S 25 N-18 G used for other T 25 tasks fits this reactor. With dispersion, use the separate 500–1,000 mL volume range.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53447735935274,"sku":"BTS-0020119961","price":10018.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-basic-system.webp?v=1793768533"},{"product_id":"ika-multidrive-control-mt-package-0010007100","title":"IKA MultiDrive control MT Milling Package, 100–120 V","description":"\u003cdiv id=\"bts-ika-md-control\" style=\"width:100%;box-sizing:border-box;max-width:1400px;margin:0 auto;font-family:Open Sans,sans-serif;font-weight:300;color:#26332C;\"\u003e\n\u003csection style=\"padding:20px;border:1px solid #B9CADA;border-radius:10px;background:#F3F6FA;\"\u003e\u003cp style=\"font-size:.85rem;font-weight:600;letter-spacing:.04em;color:#245B45;\"\u003eIKA MULTIDRIVE CONTROL MT PACKAGE • 0010007100 • US 100–120 V\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem);font-weight:600;color:#13314E;line-height:1.15;margin:0 0 20px;\"\u003eWeigh the sample. Mill in its own tube. Keep the workflow defined.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eBring \u003cstrong\u003edry-sample milling and integrated weighing\u003c\/strong\u003e into one benchtop workflow. The \u003cstrong\u003eIKA MultiDrive control MT Package\u003c\/strong\u003e pairs the TFT-controlled drive with the required \u003cstrong\u003eTC 1 protective housing\u003c\/strong\u003e and \u003cstrong\u003efive MT 150 milling tubes\u003c\/strong\u003e, each with a stainless-steel beater and up to \u003cstrong\u003e150 mL useful volume\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eChoose it for suitable dry, brittle samples when separate sample-contact tubes, visible contents and a defined weighing\/milling sequence are useful. The system processes \u003cstrong\u003eone tube at a time\u003c\/strong\u003e; five supplied tubes do not mean five simultaneous milling positions.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eA complete MT-format starting package, not every MultiDrive vessel.\u003c\/strong\u003e US order 0010007100 includes the Control drive, TC 1 and MT 150.5 five-tube pack with five spare seals. Optional MI, BL, BT and DI vessels are separate. Tube operating time, cooling and seal replacement remain essential parts of the method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Genuine IKA MultiDrive control with TC 1 protective housing and an MT tube mounted\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-system.webp?v=1793892862\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-system.webp?v=1793892862\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-system.webp?v=1793892862\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-system.webp?v=1793892862 1000w\" style=\"width:100%;max-width:620px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer illustration of the Control MT setup. Five tubes are supplied in the MT 150.5 pack; only one is processed at a time. No sample material or additional vessel family is included.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e5 × MT 150\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eSeparate tubes, not simultaneous positions\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e150 mL\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eMaximum useful volume per tube\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e3,000–20,000 rpm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eVariable speed within vessel\/method limits\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e1 min \/ 10 min\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eMT maximum run \/ minimum cooling\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eIs the Control MT package right for your samples?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eFor dry, brittle sample preparation\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eConsider suitable grains, sugar, coffee, tea and tablet samples within the manual’s size, hardness and temperature limits. Final fineness and processing time depend on the sample and method, not merely the maximum speed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eFor separate sample-contact tubes\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFive transparent plastic tubes support a defined sample workflow. Cleaning or autoclaving does not establish a universal carryover-free or sterile result; validate the method and use a fresh tube where required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eFor weighing before processing\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eTare and weigh in the same processing vessel while the drive is stopped. The Control’s integrated weighing function can reduce transfers, but its weighing range is not a claim that the MT tube accepts a 4 kg sample.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eFor short, managed batches\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eChoose it when one-minute MT runs, cooling intervals and tracked seal wear suit the workload. It is not a continuous-production mill or an unrestricted-use disposable-tube system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhat is included in US package 0010007100?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Closed MT 150 transparent milling tube with stainless-steel beater\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-tube.webp?v=1793892862\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-tube.webp?v=1793892862\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-tube.webp?v=1793892862\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-tube.webp?v=1793892862 1000w\" style=\"width:100%;max-width:500px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOne MT 150 shown. MT 150.5 \/ 0020023173 is a five-tube pack; five spare seals are supplied with the pack, not five extra seals for every tube.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eControl drive, protective housing and five-tube pack\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eIKA MultiDrive control drive, US 100–120 V, 50\/60 Hz.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eMultiDrive TC 1 protective housing, catalog 0020023489.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eMultiDrive MT 150.5, catalog 0020023173: five autoclavable MT 150 tubes with stainless-steel beaters.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eFive spare seals with the MT pack. The usage-reset procedure requires the corresponding seal code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe drive manual also lists the power-cord set, USB cable, socket wrench, disassembly tools I and II, cleaning brush, user guide and warranty card. The TC 1 manual lists disassembly tool III with the cover. These support the supplied equipment; they are not extra milling vessel families.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e MI 250-S or other reusable MI chambers, BL or BT blending vessels, DI dispersing vessels, an external cooler, sample material, an analytical balance or a software license. The explicit package scope includes MT 150.5; the manufacturer’s generic “vessels not included” paragraph refers to the other vessel choices.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCheck size, hardness and sample chemistry together\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThe supplied MT tube has its own working envelope\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eEach MT 150 has a \u003cstrong\u003e150 mL maximum useful volume\u003c\/strong\u003e, a standard stainless-steel beater and a maximum stated hardness of \u003cstrong\u003e5 Mohs\u003c\/strong\u003e. The general feed-size limit is 10 mm, but the manual requires smaller pieces as hardness increases. At 5 Mohs, the example maximum edge length is \u003cstrong\u003e5 mm\u003c\/strong\u003e, not an unconditional 10 mm allowance at maximum hardness.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe intended kit workflow is dry milling. The tube manual marks \u003cstrong\u003esolvents and abrasive substances as unsuitable\u003c\/strong\u003e. Optional hard-metal accessories elsewhere in the MultiDrive family do not give the supplied MT tube a 9-Mohs rating.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSample-contact materials include stainless steel, polycarbonate, polyamide, PTFE and silicone. Assess compatibility and possible tool\/seal abrasion for the intended analysis. Do not assume suitability for trace-metal-sensitive work or claim contamination-free results.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eDry material should not be loaded above 40°C, and the medium must not exceed 90°C under the manual’s precautions. Processing can add heat quickly. The supplied MT tube does not provide the temperature sensing found in designated optional T vessels.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Opened MT 150 tube and stainless-steel beater from the manufacturer package gallery\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-beater.webp?v=1793892862\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-beater.webp?v=1793892862\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-beater.webp?v=1793892862\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-beater.webp?v=1793892862 1000w\" style=\"width:100%;max-width:560px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eGenuine manufacturer detail. The beater is part of the MT tube, not an optional hard-metal or rotor-stator tool. Guard against sharp edges and inspect parts before use.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eTFT controls and weighing, without extra sample transfers\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Actual MultiDrive control TFT panel detail from the manufacturer image\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-controls.webp?v=1793892862\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-controls.webp?v=1793892862\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-controls.webp?v=1793892862\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-controls.webp?v=1793892862 1000w\" style=\"width:100%;max-width:560px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eActual Control display crop. Example readings are illustrative, not the supplied MT tube’s run-time or seal-life settings.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWeigh at standstill, then choose a suitable milling sequence\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe Control provides a TFT display, vessel recognition, RFID usage information and programmable speed\/time profiles. Its integrated weighing function lists a 5–4,000 g range and 1 g resolution in current technical data. Weigh only at standstill, tare as instructed and verify performance for the method.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe 4 kg weighing limit is not a working sample-mass rating for a 150 mL plastic tube. An integrated weighing function is also not a substitute for a separately specified analytical balance when the method requires one.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eVariable speed spans 3,000–20,000 rpm. The electrical ratings are \u003cstrong\u003e1,000 W input and 800 W motor output\u003c\/strong\u003e, not 1,000 W output. Local operation does not require a PC; Micro-USB is available for a separately configured software workflow.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eControl supports speed\/time programs and adjustable intermittent operation, but the loaded vessel’s shorter timer and cooling limits still apply. Temperature display and monitoring need the correct sensing vessel; those general drive capabilities are not supplied MT sample-temperature measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThree different clocks: run time, cooling and seal usage\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA short run limit is not the same as cumulative seal life\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eOne MT processing run:\u003c\/strong\u003e maximum one minute. The drive manual gives a 5-second to 1-minute timer range for MT 150\/BT 250. Do not use a generic five-minute package-table rating or another vessel’s 30-minute Control rating as an MT setting.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eCooling between MT runs:\u003c\/strong\u003e at least ten minutes per the current tube technical table. Cooling intervals are not extra processing capacity; stop and allow safe handling before opening or removing the vessel.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eMT seal usage:\u003c\/strong\u003e the current tube manual specifies a ten-minute cumulative reference for the MT 150 seal, tracked through the remaining-usage-time display. The BT 250 column is six minutes. These are different tube formats, not interchangeable service-life figures.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eWhen the applicable usage time is exhausted, replace the seal or vessel as instructed. After physically fitting a new seal, enter its supplied six-digit code in the drive’s reset procedure. Resetting the counter alone does not renew a worn part. Inspect the tube, beater and seal regularly; no unlimited number of reuse or autoclave cycles is promised.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1320\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-lifetime_phone.webp?v=1793892865\" width=\"720\"\u003e\u003cimg alt=\"MT 150 timing guide: one minute maximum run, ten minutes minimum cooling, ten minutes cumulative seal reference, then physical replacement and coded reset\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-lifetime.webp?v=1793892862\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-lifetime.webp?v=1793892862\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-lifetime.webp?v=1793892862\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-lifetime.webp?v=1793892862 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal guide based on the current MT\/BT manual, revision 032026, and drive manual. Follow the actual vessel recognition, condition and operating instructions.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSee the tube-seal maintenance format\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA’s short BT\/MT-family demonstration illustrates the seal-change format. It is not a complete operating procedure or a statement that every bench item shown is supplied. Use the current manual for the actual MT timing, disassembly, seal replacement and code-reset steps.\u003c\/p\u003e\n\u003cvideo controls=\"\" height=\"480\" playsinline=\"\" poster=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/preview_images\/3f07df0b80b34b93912fd739c2415e9b.thumbnail.0000000000.jpg?v=1793892653\" preload=\"metadata\" style=\"display:block;width:100%;max-width:876px;height:auto;margin:0 auto;border-radius:8px;background:#111;\" width=\"876\"\u003e\u003csource src=\"https:\/\/cdn.shopify.com\/videos\/c\/vp\/3f07df0b80b34b93912fd739c2415e9b\/3f07df0b80b34b93912fd739c2415e9b.SD-480p-0.9Mbps-100155854.mp4\" type=\"video\/mp4\"\u003eYour browser does not support this video.\u003c\/source\u003e\u003c\/video\u003e\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eOfficial IKA BT\/MT tube-seal demonstration, approximately 15 seconds. BT vessels and other laboratory items shown are not additional contents of this MT package.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCleaning and autoclaving: follow the tube-specific procedure\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe current tube manual lists an autoclave condition of \u003cstrong\u003e121°C, 2 bar and 20 minutes\u003c\/strong\u003e, with the upper part removed or the vessel completely disassembled. That is a manufacturer procedure reference, not a guarantee of sterility for every load, process or sample.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe MT\/BT tube manual permits dishwasher cleaning and describes cleaning with approved water\/surfactant or isopropyl alcohol. Those tube instructions do not mean the electrical drive can be autoclaved, immersed or put in a dishwasher. Follow each component’s own instructions and isolate the drive from power before cleaning or accessory work.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eWhere carryover must be excluded, choose and validate an appropriate fresh-tube workflow rather than treating reused, sterilized plastic as universally contamination-free. Autoclaving does not erase the RFID seal-usage history or replace inspection. Liquid nitrogen is not permitted for direct sample cooling. Any dry-ice method requires the full manual procedure and must never trap evolving gas in a closed tube.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA practical weigh, mill and inspect workflow\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1320\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-workflow_phone.webp?v=1793892865\" width=\"720\"\u003e\u003cimg alt=\"Dry-sample workflow: check fit, tare and weigh at standstill, secure tube under TC 1, then mill within the run and cooling limits\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-workflow.webp?v=1793892862\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-workflow.webp?v=1793892862\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-workflow.webp?v=1793892862\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-workflow.webp?v=1793892862 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal planning guide. Read the drive and MT\/TC 1 manuals before use; this is not a validated sample-preparation or safety protocol.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eDefine the method before using the maximum speed\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eConfirm sample chemistry, size, hardness, starting temperature and the tube fill limit.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eTare and weigh at standstill, then close and mount one tube correctly.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eFit the TC 1 protective housing. The interlock is required for MT operation.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eChoose appropriate speed and a run no longer than one minute; allow at least ten minutes cooling.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eInspect the sample and vessel, track cumulative seal usage, and use the specified replacement\/reset procedure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFinal fineness depends on material behavior, fill and the actual milling method. Do not infer a guaranteed mesh size, throughput, sample mass or analytical recovery from the maximum motor speed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eControl MT or Basic M20 Successor: choose the sample format\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eTwo different packages, not a simple bigger-or-smaller upgrade\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThis Control MT package\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eChoose the supplied five-tube MT format when separate 150 mL sample-contact tubes and Control weighing\/TFT functions fit the work. TC 1 is included. Apply MT-specific timing and seal limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eBasic M20 Successor package\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe separate Basic package uses a reusable 250 mL MI 250-S chamber and Basic LED controls. It does not have Control weighing\/programming, and MT 150\/BT 250 tubes do not operate on the Basic drive, even with TC 1.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eOptional Control vessel families\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eMI milling, BL\/BT blending and DI dispersing formats are separately specified options. Their capacities, temperature sensing and operating limits belong to the exact vessel, not automatically to this MT order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eAlternative format:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-multidrive-basic-m20-successor-package-0010010968?variant=53420411814186\" style=\"font-weight:600;color:#245B45;\"\u003eMultiDrive basic M20 Successor package with reusable MI 250-S chamber\u003c\/a\u003e. Compare the vessel workflow before choosing; MT and MI containers are not supplied together here.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1320\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-selection_phone.webp?v=1793892865\" width=\"720\"\u003e\u003cimg alt=\"Selection guide: Control MT with five 150 mL tubes and TC 1 versus separate Basic M20 Successor with MI 250-S 250 mL chamber\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-selection.webp?v=1793892862\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-selection.webp?v=1793892862\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-selection.webp?v=1793892862\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-selection.webp?v=1793892862 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal package-selection guide. Optional vessel families are not included in this MT package.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSafety, support and related preparation workflows\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse trained staff, suitable personal protection and process-specific safeguards. Do not bypass the protective housing or vessel interlocks. This mill is not explosion-protected; do not use it for explosive atmospheres or assume every reactive, hazardous, solvent-containing or abrasive material is suitable.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe drive manual states a 24-month baseline manufacturer warranty, excluding wear and faults caused by improper use or inadequate care. Consumable tubes, seals and normal wear are not promised unconditional coverage. Any registration extension depends on IKA’s exact applicable terms. Blue Tiger handles purchases and return requests; IKA handles warranty assessment, technical support, calibration and repairs.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-t-25-digital-ultra-turrax-disperser-drive?variant=53396356563242\" style=\"font-weight:600;color:#245B45;\"\u003eT 25 digital drive for a separately specified liquid-dispersion workflow\u003c\/a\u003e. It needs its own compatible dispersing tool and support arrangement; neither is part of this MT milling package.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:22px;margin:24px 0;border:1px solid #B7D0BF;border-radius:10px;background:#F1F7F3;box-sizing:border-box;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSpecify the sample and the tube workflow, not just the drive\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor \u003cstrong\u003e0010007100, US 100–120 V\u003c\/strong\u003e, tell Blue Tiger the sample material, initial piece size, hardness, intended fill, required result and daily workload. We can coordinate application questions and current manufacturer availability with IKA.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThis order includes the MT starting format, not every optional vessel or perpetual consumables supply. The store inventory setting is not a statement of IKA warehouse stock. Dispatch timing and final packed dimensions\/mass need order-specific confirmation.\u003c\/p\u003e\n\u003ca href=\"https:\/\/bluetigerscientific.com\/pages\/contact\" style=\"display:inline-block;max-width:100%;padding:12px 16px;box-sizing:border-box;border-radius:6px;background:#245B45;color:white;text-decoration:none;font-size:1rem;font-weight:600;line-height:1.4;\"\u003eConfirm my sample-preparation setup\u003c\/a\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;margin-top:30px;padding-top:20px;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat does MultiDrive control MT Package 0010007100 include?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe US 100–120 V package includes the MultiDrive control drive, TC 1 protective housing 0020023489 and MT 150.5 pack 0020023173. MT 150.5 supplies five MT 150 milling tubes plus five spare seals. It processes one tube at a time. MI, BL, BT and DI vessel families are not additional supplied items.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan each supplied MT 150 run for five or thirty minutes continuously?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The current drive manual limits MT 150 timer\/counter operation to 5 seconds–1 minute, and the tube manual lists a maximum one-minute processing run with at least ten minutes cooling. Generic five-minute package ratings and up-to-thirty-minute Control ratings for other vessels are not MT operating settings.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs MT 150 seal life six minutes or ten minutes?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe current MT\/BT manual’s technical table assigns ten cumulative minutes to the MT 150 seal and six to the BT 250 seal. Follow the recognized vessel’s remaining-usage-time display and current manual. Replace the worn seal or vessel as instructed, then reset using the new seal’s six-digit code; do not reset without replacing the part.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat samples fit the supplied tubes?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe intended workflow is suitable dry samples up to 150 mL useful volume per MT 150, with a standard stainless-steel beater and maximum 5 Mohs hardness. The general 10 mm feed limit becomes smaller as hardness increases; at 5 Mohs the manual example limits edge length to 5 mm. Solvents and abrasive substances are marked unsuitable.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan I autoclave and reuse MT 150 tubes indefinitely?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo unlimited reuse or cycle count is promised. The tube manual lists 121°C, 2 bar and 20 minutes with the upper part removed or the vessel disassembled. Inspect components, respect seal usage and validate cleaning\/carryover requirements. Autoclaving does not reset RFID history or prove every reused tube is contamination-free.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes the kit measure sample temperature inside MT 150?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo sample-temperature sensing is promised for the supplied MT tube. The Control drive’s general temperature functions require compatible designated sensing vessels. Loading dry material above 40°C or allowing the medium above 90°C conflicts with the tube manual’s precautions; choose the method accordingly.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eHow does this differ from the Basic M20 Successor package?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThis order is the Control drive with TFT, integrated weighing, TC 1 and five 150 mL MT tubes. Basic successor 0010010968 is a separate drive\/chamber package with a reusable 250 mL MI 250-S and Basic LED controls. MT\/BT tubes do not work on Basic even with TC 1. USB and interval operation are not exclusive Control features.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDo I need another balance, vessel or PC to start?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe supplied MT format includes its required TC 1 and tubes, and local operation does not require a PC. Control weighing lists a 5–4,000 g range and 1 g resolution, but this is not a 4 kg MT sample rating or an analytical-balance guarantee. A different vessel or separate balance may be needed for a different method. Shipping uses a provisional 30 lb packing allowance, not a measured manufacturer gross.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53465104908586,"sku":"BTS-0010007100","price":5578.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-multidrive-control-system.webp?v=1793892862"}],"url":"https:\/\/bluetigerscientific.com\/collections\/ika-milling-reactors.oembed","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}