{"title":"IKA Evaporation \u0026 Vacuum","description":"\u003cp\u003eBrowse evaporation \u0026amp; vacuum from IKA. Compare the available products below, or return to the complete brand range.\u003c\/p\u003e","products":[{"product_id":"ika-rv-10-digital-pro-v-c-complete-115v-0010012821","title":"IKA RV 10 digital pro V-C Complete Rotary Evaporator Kit, 115 V","description":"\u003cdiv id=\"bts-ika-rv10\" style=\"width:100%;box-sizing:border-box;max-width:1400px;margin:0 auto;font-family:Open Sans,sans-serif;font-weight:300;color:#26332C;\"\u003e\n\u003csection style=\"padding:22px;border:1px solid #B9CADA;border-radius:10px;background:#F3F6FA;\"\u003e\u003cp style=\"font-size:.85rem;font-weight:600;letter-spacing:.05em;color:#245B45;\"\u003eIKA RV 10 DIGITAL PRO V-C COMPLETE • 0010012821 • 115 V\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem);font-weight:600;color:#13314E;line-height:1.15;margin:0 0 20px;\"\u003eEvaporation, vacuum and cooling. One defined system.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eBuild a rotary evaporation setup around a coordinated package instead of selecting the evaporator, vacuum equipment and chiller separately. IKA catalog \u003cstrong\u003e0010012821\u003c\/strong\u003e combines the RV 10 digital, HB digital heating bath, coated vertical glassware, VACSTAR digital pump, VC 10 lite controller and RC 2 lite recirculating chiller.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThis is the manufacturer-listed \u003cstrong\u003e115 V, 50\/60 Hz Complete configuration\u003c\/strong\u003e, with 1 L evaporating and receiving flasks and the listed stand, hose set and data cable. It is not the evaporator-only purchase configuration and not the RV 10 Auto model.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor research laboratories concentrating solutions, exchanging solvents or recovering solvent under a method suited to the equipment. Choose operating conditions for your material, cooling load and laboratory safety requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"IKA RV 10 digital pro V-C Complete system with coated vertical glassware, HB digital bath, VACSTAR digital, VC 10 lite and RC 2 lite\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-kit.webp?v=1793570903\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-kit.webp?v=1793570903\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-kit.webp?v=1793570903\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-kit.webp?v=1793570903 1000w\" style=\"width:100%;max-width:600px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer photograph of the Complete package. Use the included-items checklist below, not the photograph alone, to establish order scope.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 150px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e115 V\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eManufacturer-listed kit configuration\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 150px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e1 L + 1 L\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eEvaporating and receiving flasks supplied\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 150px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003eCoated glass\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eVertical condenser, 1,500 cm² surface\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 150px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e2 mbar\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eVACSTAR digital rated final pressure\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhat is included with 0010012821?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe package brings together the main evaporation, vacuum-control and cooling components. The heating bath is included in the evaporator assembly described by IKA; the glassware set is the coated RV 10.910 configuration.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eEvaporation and collection\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eRV 10 digital FLEX assembly with HB digital heating bath, plus RV 10.910 coated vertical glassware. The package description identifies a 1 L evaporating flask and a 1 L receiving flask.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eVacuum and control\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eVACSTAR digital diaphragm vacuum pump, VC 10 lite vacuum controller and VC 10.400 stand. The controller supports manual vacuum settings and programmed operation with the supplied pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCooling and connections\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eRC 2 lite recirculating chiller, RV 10.5005 hose set and PC 1.3 cable. These are the manufacturer-listed package connections, not an invitation to substitute arbitrary hoses or power arrangements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eNot an all-consumables or all-site-services bundle.\u003c\/strong\u003e Do not assume cooling fluid, exhaust treatment, software licensing or facility electrical work is supplied. VSE 1 emission condenser is not in this package’s delivery list. Confirm any method-specific additions before ordering.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eHow the evaporation workflow fits together\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1120\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-workflow-phone.webp?v=1793571117\" width=\"720\"\u003e\u003cimg alt=\"Conceptual rotary evaporation workflow: RV 10 and HB digital warm and rotate, vertical condenser condenses vapor, receiver collects condensate; VACSTAR and VC 10 provide vacuum, RC 2 lite cools condenser\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-workflow.webp?v=1793570903\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-workflow.webp?v=1793570903\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-workflow.webp?v=1793570903\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-workflow.webp?v=1793570903 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal explanatory diagram. It shows system roles, not a tubing schematic or installation instructions. Essential steps are also explained in text.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWarm. Rotate. Condense. Collect.\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe bath supplies heat to the rotating evaporating flask. Reduced pressure supports evaporation at conditions selected for the solvent and sample. Vapor passes into the cooled condenser and collects as liquid in the receiving flask.\u003c\/p\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eRV 10 digital: rotation and motorized positioning of the evaporating flask.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eHB digital: controlled bath temperature, with a suitable tempering medium.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eCoated condenser and receiver: cooling surface and condensate collection.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eVACSTAR digital with VC 10 lite: vacuum generation and control.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eRC 2 lite: recirculating cooling to the condenser.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003ePump final pressure is a component rating, not a promise that every solvent, vessel load or operating system will run at 2 mbar. Balance heat input, vacuum and cooling rather than choosing the strongest setting on every device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhy choose this RV 10 digital package?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eMotorized positioning, with repeatable operating controls\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe RV 10 digital provides a 5–280 rpm speed range, reversible rotation, smooth start, timer and left-right interval capability. Its motorized lift has a 140 mm stroke, with an adjustable lower end stop to protect the flask from contacting the bath bottom.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA describes automatic lift-out on power loss, adjustable safety temperature, dry-run protection and a bath-setting lock. These are safeguards, not permission for unattended operation or a substitute for pre-use checks. The lift-out function is load-dependent; the drive manual requires a daily safety-lift test with the installed setup.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe drive communicates with the bath by IR. An RS 232 interface supports compatible external software control; a software license is not listed in the supplied package.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Detail of coated condenser, receiving flask, RV 10 digital drive and HB digital bath from manufacturer package photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-evaporator.webp?v=1793570903\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-evaporator.webp?v=1793570903\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-evaporator.webp?v=1793570903\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-evaporator.webp?v=1793570903 1000w\" style=\"width:100%;max-width:500px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eClose-up cropped from the manufacturer’s complete-system photograph. Display values are illustrative, not recommended process settings.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eVacuum: VACSTAR digital, not VACSTAR lite\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Included VACSTAR digital diaphragm vacuum pump, manufacturer photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-pump.webp?v=1793570903\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-pump.webp?v=1793570903\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-pump.webp?v=1793570903\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-pump.webp?v=1793570903 1000w\" style=\"width:100%;max-width:330px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eVACSTAR digital is included. Its rated 2 mbar final pressure is not a guaranteed process pressure for every solvent.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA defined pump and controller pairing\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe included VACSTAR digital is rated at a 2 mbar final pressure and a maximum delivery rate of 22 L\/min. The VC 10 lite provides the matching manual and programmable control, rather than relying on the pump alone as a complete method.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe pump must be protected from liquid carryover and used with appropriate exhaust arrangements. Follow the manual for tubing, condensate management and compatible materials. Do not close, throttle or obstruct the exhaust outlet.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eExhaust management is a separate safety decision.\u003c\/strong\u003e The pump instructions call for operation in a functioning extractor hood or exhaust routing to one. An optional emission condenser is not automatically included simply because the system contains a vacuum pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eControl: programmable vacuum is not automatic boiling-point detection\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThe “pro” package name does not change the controller model\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThis package includes \u003cstrong\u003eVC 10 lite\u003c\/strong\u003e. It supports manual vacuum settings and programmed pressure\/time operation. A PC 1.3 cable provides device communication with the chiller, as specified in the controller instructions.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eDo not confuse it with VC 10 pro, VACSTAR control or the integrated controller of RV 10 Auto. The shared VC 10 manual assigns automatic boiling-point recognition to the pro controller, not the included lite model.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eChoose this configuration when a defined digital workflow is appropriate. If integrated automatic vacuum operation is central to the method, compare the exact RV 10 Auto configuration rather than assuming that feature is hidden in this kit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Included IKA VC 10 lite vacuum controller, manufacturer photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-controller.webp?v=1793570903\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-controller.webp?v=1793570903\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-controller.webp?v=1793570903\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-controller.webp?v=1793570903 1000w\" style=\"width:100%;max-width:300px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eVC 10 lite is included; VC 10 pro is a different controller. The photograph’s display is illustrative.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCooling: size the method for the chiller, not just its headline rating\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Included IKA RC 2 lite recirculating chiller, manufacturer photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-chiller.webp?v=1793570903\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-chiller.webp?v=1793570903\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-chiller.webp?v=1793570903\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-chiller.webp?v=1793570903 1000w\" style=\"width:100%;max-width:360px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eRC 2 lite is included. Its cooling output depends on operating temperature and conditions; cooling fluid is not established as included.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003e400 W at +20 °C does not mean 400 W at −10 °C\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe RC 2 lite provides recirculating condenser cooling down to −10 °C within its stated operating conditions. Its manual lists 400 W cooling capacity at +20 °C, 350 W at +10 °C, 250 W at 0 °C and 140 W at −10 °C, according to DIN 12876.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThis matters when choosing condenser temperature and evaporation rate. A colder setpoint reduces available cooling output; flask capacity alone does not establish the achievable solvent throughput.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse a suitable cooling fluid, maintain the required liquid level and keep the stainless mesh filter clean. The RC 2 lite uses R290 refrigerant and requires a ventilated installation with the specified clearances. Do not place it in an unventilated cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhich RV 10 configuration do I need?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1280\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-selection-phone.webp?v=1793571117\" width=\"720\"\u003e\u003cimg alt=\"RV 10 package selection guide with exact catalogs: base 0010005184, coated complete 0010012821, Auto complete 0010007358 and Starter 0010014396 electrical check\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-selection.webp?v=1793570903\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-selection.webp?v=1793570903\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-selection.webp?v=1793570903\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-selection.webp?v=1793570903 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal model-selection guide. These are separate manufacturer configurations, not selectable options or extra items included in this order.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eAlready own suitable vacuum and cooling?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eRV 10 digital V, US 0010005184, is a different order containing the evaporator, bath and standard vertical glassware. Its delivery scope does not include a pump or chiller. Verify any existing peripherals rather than assuming universal compatibility.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eNeed this coated complete system?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eChoose 0010012821 for the manufacturer-listed 115 V Complete package with RV 10.910 coated glassware, VACSTAR digital, VC 10 lite and RC 2 lite. This page supplies one defined configuration, not a choice of regional versions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eNeed integrated automation?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eRV 10 auto pro V-C Complete, US 0010007358, is a separate 115 V system with integrated vacuum control and additional automated functions. Do not attribute those Auto functions to the digital kit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eConsidering the Starter Solution?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eRV 10 digital V Starter Solution, 0010014396, uses standard glassware and VACSTAR lite, rated to 9 mbar. IKA’s current US technical page lists 220–240 V. Confirm the intended electrical configuration rather than assuming every US-priced package is 115 V.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eApplications this package can support\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSolution concentration\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eReduce solvent volume in a research method using appropriately selected bath temperature, pressure and cooling. Check material compatibility and sample sensitivity before committing to operating conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSolvent exchange and work-up\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse a controlled evaporation step as part of a validated laboratory work-up. The included 1 L flask size is a vessel capacity, not a promise of a 1 L working charge or any particular processing rate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSolvent recovery and distillation\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCollect condensed solvent through the vertical condenser and receiver. Recovery depends on vapor load, cooling, leaks and solvent properties; the package does not promise a universal recovery percentage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor research laboratory use by trained personnel. The system is not explosion-proof and is not represented here as clinical, medical, diagnostic or production-scale equipment.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003ePrepare the bench before the delivery arrives\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eElectrical and space checks\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA lists this package as 115 V, 50\/60 Hz. Each powered component has its own requirements. Match every delivered rating plate, protective earth and circuit capacity; do not treat the kit as a single-plug appliance. Allow room for the glass assembly, bath, pump, controller, chiller and safe access.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChiller installation\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe RC 2 lite manual specifies at least 20 cm free space at the front and rear and a minimum room volume of 9.5 m³. Its allowed ambient range is +5 to +32 °C. Follow the R290 ventilation and installation requirements, not just the evaporator’s ambient-temperature rating.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eGlassware, fluid and exhaust\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eInspect glass and seals before use, establish cooling and fluid levels, and arrange safe pump exhaust. Coated glassware is not unbreakable and does not establish compatibility with every chemical. Request joint details if matching existing glassware is essential.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eBath fill is a setup decision, not the size printed in marketing.\u003c\/strong\u003e Use the supplied bath’s fill marks and instructions, allowing for displacement by the immersed flask. Check the actual supplied bath rather than using its nominal vessel size to decide the permitted fill.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA practical first-run sequence\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eInspect the glassware, seals, hoses and mounting; set the lower lift stop and test the safety-lift function as the drive manual requires.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eConfirm the tempering medium, cooling fluid, exhaust arrangement and all electrical connections before heating or applying vacuum.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eStart from method-appropriate settings. Observe the sample while establishing rotation, heat, cooling and reduced pressure; do not assume the pump’s lowest pressure is the right starting point.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eVent and stop in the prescribed sequence before removing the flask. Allow hot equipment and fluids to cool before handling or filling.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eAfter use, follow the component cleaning and pump-care procedures. Disconnect electrical devices before cleaning and keep moisture out of their housings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe RV 10 manual says not to fill an evaporating flask more than half its volume. That is a loading ceiling, not a guaranteed suitable charge for a foaming, bumping or otherwise difficult sample. Read the operating instructions for the installed equipment before use.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eIf the process is not behaving as expected\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eFoaming or bumping\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eReduce the severity of the conditions and reassess flask loading, heat input and how vacuum is applied. Do not try to fix carryover by choosing the maximum pump performance. Follow the method and equipment instructions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWeak condensation or poor recovery\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCheck condenser cooling, fluid flow, vapor load and the temperature-dependent chiller capacity. A −10 °C setpoint is not a 400 W cooling condition. Inspect the setup for leaks before assuming a hardware upgrade is necessary.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eUnstable vacuum or rising pump load\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eInspect tubing, seals and condensate management with the system safely stopped. Keep exhaust unobstructed and use the prescribed pump-care procedures. Contact IKA for technical service rather than opening electrical or refrigeration systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eRelated workflow: prepare solutions before concentration\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor a separate solution-preparation step, review the \u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-c-mag-hs-7-digital-magnetic-hotplate-stirrer?variant=53395441877290\" style=\"font-weight:600;color:#245B45;\"\u003eIKA C-MAG HS 7 digital magnetic hotplate stirrer\u003c\/a\u003e, using only methods and materials permitted by its own instructions.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/heathrow-scientific-glass-beakers-durable-borosilicate-lab-beakers\" style=\"font-weight:600;color:#245B45;\"\u003eHeathrow Scientific borosilicate glass beakers\u003c\/a\u003e offer separate general laboratory handling formats. Beakers are not substitutes for the supplied vacuum-rated rotary-evaporator glassware. Neither linked product is included in this kit.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;margin-top:32px;padding-top:20px;\"\u003e\u003cdiv style=\"width:100%;padding:20px 0;font-family:Open Sans,sans-serif;font-weight:300;line-height:1.15;color:#333;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat comes with IKA RV 10 digital pro V-C Complete, 0010012821?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe package includes the RV 10 digital FLEX assembly with HB digital bath, RV 10.910 coated vertical glassware with 1 L evaporating and receiving flasks, VACSTAR digital pump, VC 10 lite controller, VC 10.400 stand, RC 2 lite chiller, RV 10.5005 hose set and PC 1.3 cable. Cooling fluid, facility services and additional exhaust treatment must not be assumed included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs catalog 0010012821 the 115 V kit or the 220–240 V Starter?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIKA lists 0010012821 as the 115 V, 50\/60 Hz digital pro V-C Complete configuration. The separate Starter Solution 0010014396 currently lists 220–240 V on IKA’s US technical page. Match the exact order code and each delivered component’s rating plate; these kits are not interchangeable regional options on this page.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhy is this different from RV 10 digital V, 0010005184?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe 115 V standalone digital V order 0010005184 includes the evaporator, bath and standard vertical glassware, but no pump or chiller. Complete kit 0010012821 adds VACSTAR digital, VC 10 lite, RC 2 lite and the listed connections, and specifies coated RV 10.910 glassware.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes “pro V-C Complete” mean automatic boiling-point detection?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. This kit has VC 10 lite for manual and programmed vacuum operation. The shared controller manual assigns automatic boiling-point recognition to VC 10 pro, not lite. RV 10 auto pro V-C Complete, 0010007358, is a separate system with integrated control and additional automated functions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWill the VACSTAR digital hold my process at 2 mbar with any solvent?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo universal process pressure is promised. The 2 mbar value is the pump’s rated final pressure. Achievable system pressure depends on vapor load, leaks, temperature, solvent properties and the installed setup. Check wetted-material compatibility, condensate management and safe exhaust requirements for the actual method.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan I process a full 1 L batch because the supplied flask is 1 L?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNot on that basis. The supplied 1 L flask capacity is not the working charge. The RV 10 manual says not to fill an evaporating flask more than halfway, and difficult samples may require a lower charge. Choose loading and operating conditions for the sample, foam, bumping risk and all equipment limits.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes the RC 2 lite provide 400 W of cooling at −10 °C?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The RC 2 lite manual lists 400 W at +20 °C and 140 W at −10 °C, with 350 W at +10 °C and 250 W at 0 °C. Cooling demand and operating conditions must be matched to those temperature-dependent ratings. Suitable cooling fluid and ventilation are also required.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eHow do warranty, returns and technical service work for this kit?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIKA’s package information states two years plus three additional years after registration for the evaporator and heating bath, and two years plus one additional year for the included pump and chiller. Do not treat every item as having a five-year term. Manufacturer terms, timely registration and exclusions apply. Start return requests through Blue Tiger Scientific; IKA handles manufacturer warranty, technical service, calibration and repairs.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53420242895146,"sku":"BTS-0010012821","price":14630.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-kit.webp?v=1793570903"},{"product_id":"ika-rv-10-auto-pro-v-c-complete-115v-0010007358","title":"IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V","description":"\u003cdiv id=\"bts-ika-rv10-auto\" style=\"width:100%;box-sizing:border-box;max-width:1400px;margin:0 auto;font-family:Open Sans,sans-serif;font-weight:300;color:#26332C;\"\u003e\n\u003csection style=\"padding:20px;border:1px solid #B9CADA;border-radius:10px;background:#F3F6FA;\"\u003e\u003cp style=\"font-size:.85rem;font-weight:600;letter-spacing:.04em;color:#245B45;\"\u003eIKA RV 10 AUTO PRO V-C COMPLETE • 0010007358 • US 115 V\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem);font-weight:600;color:#13314E;line-height:1.15;margin:0 0 20px;\"\u003eIntegrated vacuum control. A matched complete kit. A defined path into Auto distillation.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eChoose a rotary-evaporation package that brings the \u003cstrong\u003eAuto drive, heating bath, vacuum pump, coated vertical glassware and recirculating chiller\u003c\/strong\u003e together under one manufacturer-defined order code. US catalog \u003cstrong\u003e0010007358\u003c\/strong\u003e adds IKA’s TFT operation and integrated vacuum controller rather than a separate VC 10 lite control box.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe included VACSTAR digital is controlled from the RV 10 Auto drive and supports automatic boiling-point detection when the system and method meet the operating conditions. It is an automation choice, not a promise of greater flask capacity, universal solvent handling or an unattended process.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe package includes the HB digital bath, RC 2 lite chiller, RV 10.910 coated vertical glassware, VSE 1 and H.SI.8 tubing. Compare its control approach with the Digital Complete kit before deciding which workflow belongs on your bench.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Manufacturer photograph of the RV 10 auto pro V-C Complete with heating bath, pump, coated glassware and chiller\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-kit.webp?v=1793771637\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-kit.webp?v=1793771637\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-kit.webp?v=1793771637\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-kit.webp?v=1793771637 1000w\" style=\"width:100%;max-width:650px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer package photograph. Display values are illustrative. Order scope follows the US 0010007358 checklist; sample, fluids, software and facility services are not established as supplied.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003eIntegrated control\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eVacuum controller in the Auto system\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e5–280 rpm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eExact package speed specification\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e1,500 cm²\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003ePublished vertical-condenser cooling surface\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003eUS 115 V\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eRegional package 0010007358\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection id=\"bts-auto-buyer-fit\" style=\"padding:24px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003cp style=\"font-size:.83rem;font-weight:600;letter-spacing:.04em;color:#245B45;margin:0 0 8px;\"\u003eA QUICK BUYING DECISION\u003c\/p\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eIs the Auto complete package right for your lab?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;padding:18px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eChoose Auto when the vacuum-control workflow matters\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe matching VACSTAR digital and integrated controller support speed-controlled vacuum operation and automatic boiling-point recognition under the method’s conditions. Choose this route when that capability contributes to your evaporation workflow, not simply because Auto sounds more powerful.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;padding:18px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eSpecify the whole core setup at once\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe factory package supplies the evaporator, bath, pump, chiller, coated glassware and listed connections. You can assess a defined hardware scope rather than discover that a bare drive still needs its vacuum and cooling equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;padding:18px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eKeep manual control available for method development\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe Auto drive provides manual and programmed operating routes as described in its instructions. Start with a suitable, reviewed method; unfamiliar evaporation processes must not simply be handed over to automatic operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;padding:18px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eChoose Digital if its control route already meets the job\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe linked Digital Complete kit uses an external VC 10 lite rather than Auto’s integrated controller. Both are complete-package choices with pump, bath, chiller and coated glassware. Compare the control functions and exact scope, not an assumed increase in batch size.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding:16px;margin-top:16px;border:1px solid #D9C49B;border-radius:8px;background:#FFF9EF;box-sizing:border-box;\"\u003e\n\u003cstrong\u003eAutomation does not remove process limits.\u003c\/strong\u003e\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSelect a different setup or seek manufacturer guidance if the required batch, material, pressure, cooling duty or facility conditions fall outside the delivered system’s limits. This is laboratory rotary evaporation, not pressure-reaction equipment, a guaranteed continuous production plant or approval to process every hazardous mixture.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhat comes in US package 0010007358?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"The complete Auto package shown as one manufacturer-defined hardware selection\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-kit.webp?v=1793771637\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-kit.webp?v=1793771637\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-kit.webp?v=1793771637\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-kit.webp?v=1793771637 1000w\" style=\"width:100%;max-width:580px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eThe same package shown again for the checklist, not a second system. A protective enclosure, process sample and consumables are not established as included.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA defined factory package, not an invented bundle\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eRV 10 auto pro rotary evaporator with integrated vacuum control and TFT interface.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eHB digital heating bath, identified in the exact package description.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eVACSTAR digital vacuum pump, controlled through the Auto system’s supplied connection arrangement.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eRV 10.910 vertical coated glassware set.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eRC 2 lite recirculating chiller.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eVSE 1 vacuum safety emission condenser.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eH.SI.8 tubing, as named in the current US order scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003ePlan the appropriate bath fluid, chiller fluid, enclosure\/exhaust arrangement and facility electrical supply against the component instructions. The drive manual specifies an all-side-closed extraction or protective enclosure and routing pump exhaust under a fume hood; these facility requirements must be arranged separately. These needs are not removed by the phrase Complete. A labworldsoft software license, protective cabinet and every possible accessory or consumable are not established as part of this order.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe glassware installation instructions identify a 1,000 mL evaporating flask in the covered set family. Do not read the package table’s bath-fill figure as a permitted sample charge, assume an additional large flask is supplied or choose spare joints from another region’s illustration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThe Auto control advantage: drive and pump working together\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Genuine Auto TFT control-panel detail from the manufacturer kit photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-controls.webp?v=1793771637\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-controls.webp?v=1793771637\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-controls.webp?v=1793771637\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-controls.webp?v=1793771637 1000w\" style=\"width:100%;max-width:420px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eActual Auto interface crop. Readings are illustrative. The vacuum-control function belongs to the Auto system, not an extra external VC 10 lite supplied with this order.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSpeed-controlled vacuum, rather than simply copying a pressure setting\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe Auto manual distinguishes a compatible speed-controlled pump from two-position vacuum-valve operation. With the matching VACSTAR digital connected correctly, pump speed adjusts as measured pressure approaches the target. The manufacturer identifies this arrangement as the basis for automatic boiling-point recognition.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe TFT interface provides the operating values, menu guidance and access to supported modes and programs. The exact package also supports soft start, reversible\/interval rotation, timed operation and ramp programming, subject to the drive instructions.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eKeep the control routes distinct.\u003c\/strong\u003e Do not add a second VC 10 lite controller or assume the manual’s RV 10 control two-position valve diagram is the Auto connection scheme. The Auto manual specifically says the RV 10.4002 vacuum valve is not required and must not be connected for this speed-control arrangement.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe chiller remains its own component with its own operating instructions. A matched package does not mean every component setting or every safety requirement is replaced by one button on the TFT display.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eAutomatic boiling-point detection needs the right cooling conditions\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThe condenser circuit is part of the measurement\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe drive manual describes Auto operation using the temperature difference between cooling-water inlet and outlet. It specifies measured flow in the 30–100 L\/h range and a constant 18–22°C reference cooling-water range. Correct inlet\/outlet installation matters; reversed connections can prevent automatic distillation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA chiller rating is not proof of actual condenser flow\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eRC 2 lite supplies recirculating cooling, but its free-flow pump rating is not the measured flow through the installed condenser circuit. Choose the coolant and settings under both component manuals and verify the actual setup rather than assume the −10°C chiller capability is the right Auto-mode setting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eReview a process before automating it\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manual requires evaporation processes to be verified before automatic use and says unfamiliar processes must not be run automatically. Solvent mixtures, foaming, bumping, thermal sensitivity and vapor load require method-specific assessment. Auto is not an unattended-operation or guaranteed-endpoint claim.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eVACSTAR digital and VSE 1: a defined vacuum path\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Included VACSTAR digital pump model shown separately in a manufacturer photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-pump.webp?v=1793771637\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-pump.webp?v=1793771637\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-pump.webp?v=1793771637\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-pump.webp?v=1793771637 1000w\" style=\"width:100%;max-width:470px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eComponent photograph of the included pump model, not a second pump. Follow the supplied pump and VSE instructions for installation, exhaust and chemical compatibility.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eControl the pump and manage the exhaust properly\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe VACSTAR digital provides the compatible pumping route for the Auto drive. IKA quotes a 2 mbar final pressure for the pump. That is a component specification, not a guaranteed process pressure for every solvent, gas load, leak rate or operating temperature.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eVSE 1 is included as a vacuum safety emission condenser. It supports solvent-vapor management under its specified installation and operating conditions, but it does not replace a suitable laboratory ventilation and exhaust strategy or guarantee zero emissions.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eKeep the vacuum path, cooling path and exhaust arrangement distinct, and assess wetted-material compatibility for the actual media. Never treat an ultimate-vacuum figure as permission for overpressure, arbitrary reactive mixtures or unrestricted hazardous-vapor discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCoated vertical glassware is a specification, not a safety shortcut\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eMatch the delivered US parts before selecting accessories\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe specified set is \u003cstrong\u003eRV 10.910\u003c\/strong\u003e vertical coated glassware, with a published 1,500 cm² condenser cooling surface in the exact package data. The transparent coating can help retain fragments if coated glass breaks; it does not make damaged glass safe or turn the apparatus into explosion-protected equipment.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manufacturer’s glassware installation notes give separate temperature limits for the coated material, including a −30 to +60°C range for the specified Surlyn-coated parts. Do not assume the bath’s 180°C capability is a temperature rating for every coated component. Identify which delivered pieces are coated and follow their instructions.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eInspect glass and seals, avoid mechanical stress and observe the drive’s lift and flask-load instructions. Use the delivered US component codes when choosing replacements; an NS 29 family illustration is not proof that every joint on this US package uses that standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Coated vertical glassware detail from the Auto kit photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-glass.webp?v=1793771637\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-glass.webp?v=1793771637\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-glass.webp?v=1793771637\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-glass.webp?v=1793771637 1000w\" style=\"width:100%;max-width:430px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer-photo detail of the same supplied set. No extra condenser or flask is added by this illustration. Verify the delivered components and applicable coated-part limits.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eHB digital: choose the fluid and fill for the actual flask\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"HB digital bath detail from the Auto package photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-bath.webp?v=1793771637\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-bath.webp?v=1793771637\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-bath.webp?v=1793771637\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-bath.webp?v=1793771637 1000w\" style=\"width:100%;max-width:470px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eActual bath in the kit image. Displayed values are illustrative; bath fluid, fill and sample method must follow the supplied instructions.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThe bath rating is not a sample-temperature guarantee\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA describes the included HB digital as a 4 L water\/oil heating bath with a room-temperature-to-180°C heating range. Choose the approved bath fluid for the temperature and observe the actual fill marks, flask displacement, residual heat and the delivered bath instructions.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe exact kit table and the bath manual contain different maximum-fill and electrical-power figures. For that reason this page does not turn a single conflicting table value into a guaranteed maximum working fill or a combined electrical-load rating for the whole package.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eDo not interpret a nominal bath capacity as the amount of sample to put in the evaporating flask. Verify the permitted flask charge, immersion, lift travel and load together. Facility electrical planning must account for each component’s rating plate; one-outlet operation is not promised.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eRC 2 lite: condenser cooling without a mains-water assumption\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA supplied chiller, not unlimited cooling capacity\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe RC 2 lite is part of the package and uses R290 refrigerant. The manufacturer quotes a 400 W cooling-capacity reference and cooling capability down to −10°C, but available capacity depends on operating temperature and conditions. Do not assume 400 W is available at every setpoint or that the coldest setting is appropriate for Auto detection.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe chiller manual specifies component pump limits and coolant requirements. Keep the actual condenser flow and pressure within the limits of every connected part, including the glassware. Use the approved fluid and observe fill, ventilation, ambient and refrigerant precautions in the manual.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCondenser temperature, vapor generation and capture need to work together. If the required duty exceeds the chiller or condensation setup, reducing pressure or increasing the bath setting is not automatically the answer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"RC 2 lite chiller detail from the Auto package photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-chiller.webp?v=1793771637\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-chiller.webp?v=1793771637\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-chiller.webp?v=1793771637\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-chiller.webp?v=1793771637 1000w\" style=\"width:100%;max-width:470px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eThe included chiller shown as a genuine kit-photo crop. Illustrative display, not a recommended temperature or a guarantee of cooling duty.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA practical Auto evaporation workflow\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1260\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-workflow_phone_verified.webp?v=1793772298\" width=\"720\"\u003e\u003cimg alt=\"Corrected Auto workflow: configure, establish cooling and vacuum, warm and rotate, condense and collect\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-workflow_verified.webp?v=1793772299\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-workflow_verified.webp?v=1793772299\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-workflow_verified.webp?v=1793772299\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-workflow_verified.webp?v=1793772299 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eConceptual roles only, not tubing, valve or safety instructions. Configure and verify the method before using automatic operation.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eConfigure the method first, then use the control functions\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eInspect and correctly assemble the delivered glassware, seals and flask; select a suitable charge and safe material handling arrangement.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eCheck the lift, end stop, permitted load, bath fluid\/fill and the manufacturer’s daily safety-lift test before operation.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eConnect the cooling and vacuum routes exactly as specified, including the compatible pump data connection and the correct condenser inlet\/outlet. Follow the mode-specific commissioning sequence: evacuate the glassware before heating the sample, and keep the evaporating flask rotating during heating.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eSet the appropriate temperatures, rotation and mode for a reviewed method. Confirm actual flow and cooling conditions before automatic detection.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eObserve condensation and collection, then follow the correct stopping, cooling and pressure-equalization sequence before opening or cleaning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eAutomatic boiling-point detection and volume-dependent distillation are different control routes. The manual says those two modes are mutually exclusive; volume-based operation needs its own solvent\/efficiency setup and a test distillation. It is not an uncalibrated promise to collect an exact volume from any mixture.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eDigital or Auto: choose the control workflow\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1320\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-selection_phone.webp?v=1793771640\" width=\"720\"\u003e\u003cimg alt=\"Original Digital Complete versus Auto Complete decision guide\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-selection.webp?v=1793771637\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-selection.webp?v=1793771637\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-selection.webp?v=1793771637\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-selection.webp?v=1793771637 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eBoth referenced products are complete-package selections. This order is US Auto 0010007358; Digital 0010012821 is a separate alternative.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose this Auto kit for the integrated approach\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eTFT operation, integrated vacuum control and supported automatic boiling-point recognition with the matched VACSTAR digital. Choose it when those functions support a reviewed, suitable process and correct cooling setup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose Digital when its external-controller route fits\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe Digital pro V-C Complete kit uses the separate VC 10 lite controller. It still supplies a bath, pump, chiller and coated glassware, so Auto should not be sold as merely adding equipment that Digital lacks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eDo not choose Auto as an assumed scale-up\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eNo higher batch capacity, universal processing speed or solvent-recovery percentage is promised here. Check the delivered flask, charge, condenser duty, pressure and safety limits against the actual application.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCare, safety and warranty by component\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCoated glassware, heated fluid, vacuum, rotating equipment, solvent vapor and R290 refrigeration each have their own handling requirements. Do not run damaged equipment, bypass protections, treat the system as overpressure-rated or assume it is explosion-protected. Trained staff must assess the medium and facility conditions.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe drive instructions limit flask filling to no more than half its volume and give a separate 3 kg maximum for the evaporating flask plus its contents. The standard-assembly daily safety-lift check uses 3.1 kg total glassware plus solvent, not 3.1 kg of solvent alone. These are separate constraints, not interchangeable sample allowances; the safe charge may be lower for the actual glassware, balance and method. Follow the delivered configuration and test the safety lift daily.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eStop, allow safe handling temperatures, isolate power and follow the required pressure-equalization, cleaning and decontamination instructions. Blue Tiger Scientific handles purchase and return requests; IKA handles manufacturer technical support, warranty assessment, calibration where applicable and repairs.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe current exact-package page states a standard two-year warranty. It describes registration extensions of three additional years for the rotary evaporator and heating bath, and one additional year for the included pump and chiller, subject to IKA’s registration requirements, terms and exclusions. This is not an unconditional five-year warranty on every item in the package.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eRelated equipment and alternative workflows\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eAlternative model:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-rv-10-digital-pro-v-c-complete-115v-0010012821?variant=53420242895146\" style=\"font-weight:600;color:#245B45;\"\u003eRV 10 digital pro V-C Complete, US 115 V\u003c\/a\u003e for the external VC 10 lite control route. Compare the control features and current package scope, not just the shared RV 10 name.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-lr-1000-control-laboratory-reactor-system-115v-0025001992?variant=53447374733610\" style=\"font-weight:600;color:#245B45;\"\u003eLR 1000 control for a separate formulation-development stage\u003c\/a\u003e. This is not a reactor attachment or proof that its sample may be transferred into an evaporator without method review.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-multidrive-basic-m20-successor-package-0010010968?variant=53420411814186\" style=\"font-weight:600;color:#245B45;\"\u003eMultiDrive basic M20 Successor Package for separately specified dry sample preparation\u003c\/a\u003e. It is not a solvent mill or an accessory included with this evaporation package.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"bts-auto-purchase-guide\" style=\"padding:22px;margin:24px 0;border:1px solid #B7D0BF;border-radius:10px;background:#F1F7F3;box-sizing:border-box;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eReady to specify the Auto complete package?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eFor the standard US setup:\u003c\/strong\u003e choose catalog 0010007358 when the delivered coated glassware, integrated-control approach and component capabilities fit your method. Review the scope and facility requirements rather than assuming every RV 10 listing is the same complete configuration.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eFor options or procurement confirmation:\u003c\/strong\u003e tell Blue Tiger the application, typical batch, solvent class, desired mode and receiving\/delivery requirements. Ask us to confirm the exact US scope, request current manufacturer availability and dispatch information, and coordinate manufacturer application questions before a time-critical purchase.\u003c\/p\u003e\n\u003ca href=\"https:\/\/bluetigerscientific.com\/pages\/contact\" style=\"display:inline-block;max-width:100%;padding:12px 16px;box-sizing:border-box;border-radius:6px;background:#245B45;color:white;text-decoration:none;font-size:1rem;font-weight:600;line-height:1.4;\"\u003eAsk about options or availability\u003c\/a\u003e\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eMention RV 10 auto pro V-C Complete and catalog 0010007358. Shipping-weight allowance and automated arrival dates are estimates, not a confirmed manufacturer gross weight or supplier lead time.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;margin-top:30px;padding-top:20px;\"\u003e\u003cdiv style=\"width:100%;padding:18px 0;font-family:Open Sans,sans-serif;font-weight:300;line-height:1.15;color:#333;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat is included in US RV 10 Auto Complete package 0010007358?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIKA’s current US scope lists RV 10 auto pro, VACSTAR digital, RV 10.910 coated vertical glassware, H.SI.8 tubing, VSE 1 and RC 2 lite. The exact description also includes the HB digital heating bath. Fluids, a software license, protective cabinet and every possible facility or exhaust accessory are not established as supplied. Confirm the delivered parts before selecting spares.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat does Auto add compared with the Digital Complete kit?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eAuto 0010007358 has the TFT interface and integrated vacuum-control approach, with automatic boiling-point detection supported by the matching VACSTAR digital and correct operating conditions. Digital Complete 0010012821 uses an external VC 10 lite controller. Both are complete hardware packages; Auto is not automatically a larger-batch or higher-throughput version.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes automatic boiling-point detection mean I can leave any sample unattended?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The manual requires evaporation processes to be verified before automatic use and says unfamiliar processes must not simply be automated. Correct pump, cooling-flow and temperature setup is required. Foaming, bumping, mixtures and hazardous media still need method-specific safeguards and trained supervision.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhy does cooling setup affect automatic operation?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe drive uses the temperature difference between condenser cooling-water inlet and outlet. Its manual specifies 30–100 L\/h measured flow and a constant 18–22°C reference cooling-water range. Reversed inlet\/outlet connections can prevent automatic distillation. A chiller’s maximum free-flow or lowest setpoint does not prove that the installed circuit meets these conditions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes the 2 mbar pump specification guarantee that process pressure?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The 2 mbar figure is the manufacturer’s VACSTAR digital final-pressure specification. Actual process pressure depends on the solvent, vapor load, leaks, temperature and setup. The Auto drive controls the compatible pump through its specified connection; do not add the manual’s separate two-position vacuum valve as if it were the Auto pump arrangement.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan I treat the 4 L bath or 180°C rating as the sample charge and temperature?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. Bath capacity is not evaporating-flask charge, and the heating range is not permission to heat every sample or coated glass component to 180°C. The exact kit table and bath manual also differ on maximum fill and power figures. Use the actual bath marks, flask displacement, fluid choice, coated-part limits and delivered instructions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs the whole package covered by an unconditional five-year warranty?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The current package page states two years standard, with registration extensions described separately: three additional years for the rotary evaporator and bath, and one additional year for pump and chiller. IKA’s applicable registration rules, terms and exclusions govern coverage; this is not a five-year promise for every glass, wear or peripheral part.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs 21.5 kg the shipping weight, and how will this equipment be delivered?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo confirmed packed kit gross is established by that headline figure. The store uses a documented 190 lb provisional aggregate packing allowance for the complete system, not a claim that it ships as one parcel or that IKA measured that gross. Mainland equipment delivery rates are configured; Alaska\/Hawaii freight, territories, international destinations and special services require a quote.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53448457257258,"sku":"BTS-0010007358","price":16460.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rv10-auto-kit.webp?v=1793771637"},{"product_id":"ika-vacstar-control-vacuum-pump-0020109376","title":"IKA VACSTAR control Diaphragm Vacuum Pump with Integrated Controller","description":"\u003cdiv id=\"bts-ika-vacstar-control\" style=\"width:100%; max-width:1400px; box-sizing:border-box; margin:0 auto; font-family:Open Sans, sans-serif; font-weight:300; color:#26332C;\"\u003e\n\u003cstyle\u003e#bts-ika-vacstar-control *{box-sizing:border-box}#bts-ika-vacstar-control a{overflow-wrap:anywhere}#bts-ika-vacstar-control summary{line-height:1.5}@media(max-width:600px){#bts-ika-vacstar-control section{padding:18px 0!important}#bts-ika-vacstar-control section:first-of-type{padding:16px!important}#bts-ika-vacstar-control h2{margin-bottom:12px!important}#bts-ika-vacstar-control p,#bts-ika-vacstar-control li{line-height:1.6!important}}\u003c\/style\u003e\n\u003csection style=\"padding:24px; border:1px solid #B9CADA; border-radius:10px; background:#F3F6FA;\"\u003e\u003cp style=\"font-size:.85rem; font-weight:600; letter-spacing:.04em; color:#245B45;\"\u003eIKA VACSTAR CONTROL • US ORDER 0020109376 • 100–240 V\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem); font-weight:600; color:#13314E; line-height:1.15; margin:0 0 20px;\"\u003ePut vacuum control at the pump, and keep the method in view.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; align-items:center; gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px; min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eThe \u003cstrong\u003eIKA VACSTAR control\u003c\/strong\u003e combines a dry four-chamber diaphragm vacuum pump with an \u003cstrong\u003eintegrated vacuum controller, ceramic pressure sensor and removable WiCo display\u003c\/strong\u003e. Select a pressure target, use automatic boiling-point detection under suitable conditions, or work with defined pressure-time programs.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eIts separate reference ratings are \u003cstrong\u003e22 L\/min maximum pumping rate\u003c\/strong\u003e and \u003cstrong\u003e2 mbar ultimate pressure without gas ballast\u003c\/strong\u003e. Those are not a promise of 22 L\/min flow at 2 mbar. Your apparatus, leaks, vapour load and protection equipment determine the actual operating point.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eUS order \u003cstrong\u003e0020109376\u003c\/strong\u003e is rated \u003cstrong\u003e100–240 V, 50\/60 Hz\u003c\/strong\u003e. It is a controlled laboratory vacuum source, not a liquid-transfer pump, pressure pump or universal solution for hazardous gases.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px; min-width:0;\"\u003e\u003cfigure style=\"margin:0; min-width:0;\"\u003e\u003cimg alt=\"Genuine IKA VACSTAR control pump photograph with removable WiCo controller\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-system.webp?v=1793924401\u0026amp;format=webp\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-system.webp?v=1793924401\u0026amp;format=webp\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-system.webp?v=1793924401\u0026amp;format=webp\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-system.webp?v=1793924401\u0026amp;format=webp 1000w\" style=\"width:100%; max-width:560px; height:auto; object-fit:contain; display:block; margin:0 auto; border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem; line-height:1.5; color:#526158; margin-top:10px;\"\u003eManufacturer photograph. An illustrative screen does not establish a supplied sample-temperature probe. Exact emissions and condensate hardware must be confirmed for the application.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:12px; padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 150px; min-width:0; padding:16px; border:1px solid #e0e0e0; border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block; font-size:1.2rem; color:#13314E;\"\u003e22 L\/min\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem; line-height:1.5;\"\u003eMaximum pumping-rate reference\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 150px; min-width:0; padding:16px; border:1px solid #e0e0e0; border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block; font-size:1.2rem; color:#13314E;\"\u003e2 mbar\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem; line-height:1.5;\"\u003eUltimate pressure, without gas ballast\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 150px; min-width:0; padding:16px; border:1px solid #e0e0e0; border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block; font-size:1.2rem; color:#13314E;\"\u003eIntegrated control\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem; line-height:1.5;\"\u003eWiCo and ceramic pressure sensor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 150px; min-width:0; padding:16px; border:1px solid #e0e0e0; border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block; font-size:1.2rem; color:#13314E;\"\u003eFour control modes\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem; line-height:1.5;\"\u003eAutomatic, Manual, Pump %, Program\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"padding:26px 0; border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eIs VACSTAR control the right vacuum source?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px; min-width:0; border:1px solid #B7D0BF; border-radius:8px; background:#F1F7F3; padding:20px; box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eControlled laboratory evacuation\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eFor suitable separation, filtration, drying and rotary-evaporation workflows. Define the target pressure and vapour load before choosing the pump; a final-pressure headline is not a throughput specification.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px; min-width:0; border:1px solid #B7D0BF; border-radius:8px; background:#F1F7F3; padding:20px; box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eYou want pressure control at the pump\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eThe controller and sensor are part of this model. A separate external vacuum controller is not established as necessary for ordinary standalone pump operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px; min-width:0; border:1px solid #B7D0BF; border-radius:8px; background:#F1F7F3; padding:20px; box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eYou can protect the pump and the room\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eUse appropriate liquid separation, vapour management and an unrestricted exhaust route. A condensate trap and downstream emission treatment perform different jobs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px; min-width:0; border:1px solid #B7D0BF; border-radius:8px; background:#F1F7F3; padding:20px; box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eThe gas service is permitted\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eCheck the actual wetted materials and manufacturer restrictions. Chemical-resistant construction is not approval to pump liquids, explosive or corrosive gases, or to work in an explosive atmosphere.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0; border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eWhat is included in US order 0020109376?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; align-items:center; gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px; min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003ePump, WiCo and the current listed US accessories\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003eVACSTAR control diaphragm pump with integrated vacuum controller and pressure sensor.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003eRemovable WiCo controller.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003eVacuum hose, 1 m.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003eWH11 and OS 1.0 WiCo power supply.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003eUSB A to Micro-B cable, 2 m, and USB A–B cable.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003eScrewdriver.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eThe operating manual also shows a power-cord set, cover, bracket, receiving flask, spherical clamp and a short connection hose. Its illustrations are not a substitute for confirming the current US factory assembly or exact regional packing.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003e\u003cstrong\u003eA separate VSE 1 accessory is not promised as included.\u003c\/strong\u003e The current US description calls VSE 1 an accessory, while its technical table marks emission condenser and condensate trap as present. The manual depicts additional receiving hardware and also lists VSE 1 as an accessory. Confirm the exact supplied assembly and any additional required items before ordering for an emissions-critical method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px; min-width:0;\"\u003e\u003cfigure style=\"margin:0; min-width:0;\"\u003e\u003cimg alt=\"Manufacturer photograph of separate VSE 1 vacuum safety emission condenser, not promised as included\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-optional.webp?v=1793924401\u0026amp;format=webp\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-optional.webp?v=1793924401\u0026amp;format=webp\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-optional.webp?v=1793924401\u0026amp;format=webp\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-optional.webp?v=1793924401\u0026amp;format=webp 1000w\" style=\"width:100%; max-width:400px; height:auto; object-fit:contain; display:block; margin:0 auto; border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem; line-height:1.5; color:#526158; margin-top:10px;\"\u003eVSE 1 accessory, US catalog 0035001873, shown for selection only. This page does not promise an additional separate VSE 1 unit, nor claim that the pump ships without any condensate or emission hardware.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0; border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eRead pumping rate, ultimate pressure and sensor range separately\u003c\/h2\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; align-items:center; gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px; min-width:0;\"\u003e\u003cfigure style=\"margin:0; min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1460\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-performance_phone.webp?v=1793924401\u0026amp;format=webp\" width=\"720\"\u003e\u003cimg alt=\"Buyer guide distinguishing 22 L per minute maximum, 2 mbar ultimate vacuum and 1 mbar sensor resolution\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-performance.webp?v=1793924401\u0026amp;format=webp\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-performance.webp?v=1793924401\u0026amp;format=webp\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-performance.webp?v=1793924401\u0026amp;format=webp\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-performance.webp?v=1793924401\u0026amp;format=webp 1200w\" style=\"width:100%; max-width:700px; height:auto; object-fit:contain; display:block; margin:0 auto; border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem; line-height:1.5; color:#526158; margin-top:10px;\"\u003eOriginal guide based on IKA specifications. These are different quantities, not a simultaneous performance point or a guarantee for a connected apparatus.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px; min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eThe system load decides what happens between the endpoints\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003e\u003cstrong\u003e22 L\/min, or 1.32 m³\/h\u003c\/strong\u003e, is the maximum pumping-rate reference. The \u003cstrong\u003e2 mbar final-pressure value is specified without gas ballast\u003c\/strong\u003e. Do not combine the two as guaranteed suction performance at the lowest pressure.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eThe ceramic Al₂O₃ sensor has a stated \u003cstrong\u003e1–1,030 mbar absolute measurement range\u003c\/strong\u003e, \u003cstrong\u003e1 mbar resolution\u003c\/strong\u003e and \u003cstrong\u003e1 mbar measurement uncertainty\u003c\/strong\u003e. The web table’s control-range figure does not turn this into a pump guaranteed to reach 1 mbar.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eLeaks, restrictions, condensable vapours, apparatus volume and method conditions all influence evacuation and regulation. The pump is a rough-vacuum laboratory source, not an oil-sealed high-vacuum pump or a promise of any particular evaporation rate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0; border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eChoose the control mode that matches the method\u003c\/h2\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; align-items:center; gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px; min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003ePressure control is not the same as fixed pumping output\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003eAutomatic: boiling-point recognition for a suitable, thermally stable evaporation method. The manual requires a constant thermal condition for rotary-evaporation use; this is not universal recognition of every mixture.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003eManual: enter the pressure target within permitted settings and the pump’s achievable limits.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003ePump %: select pumping output rather than assume a fixed pressure.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003eProgram: create up to ten user-defined pressure-time profiles, each with up to ten segments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eThe solvent library helps relate stored solvent pressure and temperature information. It does not establish compatibility with every solvent, identify an unknown mixture, provide a sample-temperature probe or replace method development.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eThe manual states that the timer function is disabled in Automatic and Program modes. Nominal drive-speed data is 285–1,200 rpm, while automatic regulation can reduce pumping to zero when the target and system leak rate allow it. No fixed minimum running speed is promised at a stable target.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px; min-width:0;\"\u003e\u003cfigure style=\"margin:0; min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1460\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-modes_phone.webp?v=1793924401\u0026amp;format=webp\" width=\"720\"\u003e\u003cimg alt=\"VACSTAR mode-selection guide: Automatic, Manual, Pump percent and Program\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-modes.webp?v=1793924401\u0026amp;format=webp\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-modes.webp?v=1793924401\u0026amp;format=webp\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-modes.webp?v=1793924401\u0026amp;format=webp\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-modes.webp?v=1793924401\u0026amp;format=webp 1200w\" style=\"width:100%; max-width:700px; height:auto; object-fit:contain; display:block; margin:0 auto; border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem; line-height:1.5; color:#526158; margin-top:10px;\"\u003eOriginal mode overview. Timer restrictions and the connected apparatus’s operating limits still apply.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0; border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eWiCo: local controls, removable display and deliberate safety settings\u003c\/h2\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; align-items:center; gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px; min-width:0;\"\u003e\u003cfigure style=\"margin:0; min-width:0;\"\u003e\u003cimg alt=\"Enlarged crop of the real VACSTAR control WiCo screen and operating knob\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-controls.webp?v=1793924401\u0026amp;format=webp\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-controls.webp?v=1793924401\u0026amp;format=webp\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-controls.webp?v=1793924401\u0026amp;format=webp\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-controls.webp?v=1793924401\u0026amp;format=webp 1000w\" style=\"width:100%; max-width:300px; height:auto; object-fit:contain; display:block; margin:0 auto; border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem; line-height:1.5; color:#526158; margin-top:10px;\"\u003eActual manufacturer-photo crop. Screen values are illustrative settings, not a validated process or proof of temperature-measuring equipment in the box.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px; min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eA computer and internet connection are not required for local operation\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eOperate the pump through WiCo on the station or in an appropriately configured remote position. The manual describes Bluetooth communication up to 150 m depending on the building. That is not a guaranteed laboratory range, internet access or a cloud-control service. Wireless use must comply with the device’s regional radio approval; otherwise keep WiCo on the station.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003e\u003cstrong\u003eLoss of WiCo communication is not a universal automatic shutdown.\u003c\/strong\u003e Timeout, safety-pressure and safety-pump-rate settings affect what happens after a communication failure or battery depletion. Configure them for the process and retain access to the station’s stopping controls. If vibration requires it, secure WiCo as directed or position it remotely.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eUSB-B and RS-232 support separately configured computer workflows. Any software license and required optional communication cable are separate selections. No validated electronic-recordkeeping or regulatory-compliance claim is made.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0; border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eSeparate liquid protection from exhaust-vapour management\u003c\/h2\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; align-items:center; gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px; min-width:0;\"\u003e\u003cfigure style=\"margin:0; min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1460\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-protection_phone.webp?v=1793924401\u0026amp;format=webp\" width=\"720\"\u003e\u003cimg alt=\"Planning guide separating upstream liquid protection, the diaphragm pump and downstream exhaust management\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-protection.webp?v=1793924401\u0026amp;format=webp\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-protection.webp?v=1793924401\u0026amp;format=webp\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-protection.webp?v=1793924401\u0026amp;format=webp\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-protection.webp?v=1793924401\u0026amp;format=webp 1200w\" style=\"width:100%; max-width:700px; height:auto; object-fit:contain; display:block; margin:0 auto; border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem; line-height:1.5; color:#526158; margin-top:10px;\"\u003eOriginal planning overview, not a piping diagram or verified bill of materials. Choose the actual assembly under the pump, accessory and apparatus instructions.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px; min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eA trap before the pump does not replace a safe exhaust route\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eArrange the process so liquid, condensate and solids cannot enter the pump chambers. The manual calls for suitable upstream condensate separation, such as a Woulff-bottle arrangement, and routing that prevents liquid carryover. The receiving hardware shown with a pump does not prove that every upstream protection function is already installed.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eDownstream condensation addresses vapours leaving the pump. Where VSE 1 is selected, follow its instructions and maintain free coolant flow. A cooling source, coolant connections and a complete application-specific installation are not promised by an accessory name or a Yes field in a table.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003e\u003cstrong\u003eKeep the exhaust unrestricted and routed to a suitable fume hood.\u003c\/strong\u003e The manual limits the exhaust line to 2 m and requires it to remain free of kinks. Do not throttle or close the discharge. Neither this listing nor a condenser specification guarantees zero emissions or replaces appropriate ventilation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0; border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eInstallation and media limits are part of the buying decision\u003c\/h2\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; align-items:center; gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px; min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eCheck more than the nominal vacuum number\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003eUse a stable, dry, level, non-slip and fire-resistant indoor bench with ventilation openings unobstructed. Operate the pump upright, and do not mount it above a heating bath.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003eThe pump uses 8 mm suction and discharge connection references. Select matching vacuum-rated flexible hoses, secure connections and suitable apparatus; do not identify ports from a diagram number alone.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003ePublished input-pressure data is 2–1,030 mbar. The manual’s 1,100 mbar maximum at gas inlet\/outlet is a safety ceiling, not permission to use this as a compressor. The sensor’s separate 1.2 bar maximum is not a system operating allowance.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003eDo not pump liquids or evacuate explosive or corrosive gases. Do not use in explosive atmospheres, underwater or for biological habitats. Prevent liquids and solids entering the diaphragm chambers.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem; line-height:1.7; padding:4px 0;\"\u003eStop and disconnect mains before installation changes or external cleaning. Keep the power connection accessible and check the rating plate against the supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eMaterials named in manufacturer data include Al₂O₃, PTFE and PPS, but the short list and detailed manual differ in elastomer nomenclature. Confirm the exact current seals and diaphragms for chemically critical service instead of assuming that all wetted parts are PTFE or universally solvent resistant.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px; min-width:0;\"\u003e\u003cfigure style=\"margin:0; min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1460\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-setup_phone.webp?v=1793924401\u0026amp;format=webp\" width=\"720\"\u003e\u003cimg alt=\"Application checklist for permitted media, free exhaust, upright installation and WiCo failure settings\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-setup.webp?v=1793924401\u0026amp;format=webp\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-setup.webp?v=1793924401\u0026amp;format=webp\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-setup.webp?v=1793924401\u0026amp;format=webp\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-setup.webp?v=1793924401\u0026amp;format=webp 1200w\" style=\"width:100%; max-width:700px; height:auto; object-fit:contain; display:block; margin:0 auto; border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem; line-height:1.5; color:#526158; margin-top:10px;\"\u003eOriginal safety-planning checklist, not a substitute for the operating manual or an application risk assessment.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0; border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eRelated equipment: do not buy a second pump by mistake\u003c\/h2\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px; min-width:0; border:1px solid #B7D0BF; border-radius:8px; background:#F1F7F3; padding:20px; box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eRV 10 digital pro V-C Complete\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eIKA lists this family as compatible, but the existing Complete package already includes a vacuum-pump arrangement. This listing is not a recommendation to add a second pump. Any alternate-pump\/controller arrangement needs separate review.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px; min-width:0; border:1px solid #B7D0BF; border-radius:8px; background:#F1F7F3; padding:20px; box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eLR 1000 laboratory reactors\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eIKA’s compatibility list names LR1000 basic and control systems. Connections, vessel vacuum limits, seals, liquid protection and the actual process must still be checked. A compatibility listing is not a turnkey reactor vacuum installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px; min-width:0; border:1px solid #B7D0BF; border-radius:8px; background:#F1F7F3; padding:20px; box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eOther laboratory vacuum tasks\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eChoose a separately specified pump\/controller format if you do not need these control features or need a different gas-service, throughput or final-pressure range. Do not assume any pump with an 8 mm connector is interchangeable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-rv-10-digital-pro-v-c-complete-115v-0010012821?variant=53420242895146\" style=\"font-weight:600; color:#245B45;\"\u003eRV 10 digital pro V-C Complete, with its own included vacuum equipment\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-lr-1000-control-laboratory-reactor-system-115v-0025001992?variant=53447374733610\" style=\"font-weight:600; color:#245B45;\"\u003eLR 1000 control reactor for a separately specified vacuum application\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003e\u003cstrong\u003eAlternative format:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-lr-1000-basic-laboratory-reactor-system-0020119961?variant=53447735935274\" style=\"font-weight:600; color:#245B45;\"\u003eLR 1000 basic reactor with its own process and connection limits\u003c\/a\u003e.\u003c\/p\u003e\n\u003csection style=\"padding:26px 0; border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eCare, warranty and delivery planning\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eInspect hoses, seals, connections and receiving hardware for damage or contamination. The manual describes no-load air purging at the end of a process, approximately three up to a maximum of five minutes, and separately configurable Cleaning-mode settings. That is pump-purging guidance, not a liquid-wash, disinfection or sterility cycle. Keep discharged vapours safely captured and follow the complete procedure.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eFor external cleaning, disconnect mains and prevent moisture entering the device. Do not immerse the powered unit. Diaphragms, valves and seals are wear-related service items; a dry pump is not maintenance-free. Use IKA’s service and decontamination procedures for repairs.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eThe operating manual gives a 24-month warranty baseline under IKA terms, excluding wear and improper use or care. Any registration extension depends on current exact-model terms. Blue Tiger handles purchases and return requests; IKA handles manufacturer warranty assessment, technical support, calibration and repairs.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eShipping uses a documented 45 lb provisional package-planning allowance, not the published 14 kg device mass as verified boxed weight. Actual cartons, dimensions, carrier handling, supplier availability and dispatch require confirmation. Store inventory is not evidence of manufacturer warehouse stock.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:22px; margin:24px 0; border:1px solid #B7D0BF; border-radius:10px; background:#F1F7F3;\"\u003e\u003ch2 style=\"font-size:1.45rem; line-height:1.25; font-weight:600; color:#245B45; margin:0 0 18px;\"\u003eSpecify the vacuum task and the complete protection route\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eFor \u003cstrong\u003eVACSTAR control \/ US 0020109376\u003c\/strong\u003e, tell Blue Tiger the apparatus, target pressure, expected vapour load, media, hose route and existing condensate\/emissions hardware. We can coordinate configuration and application questions with IKA. Name the exact kit if you already own a Complete rotary evaporator.\u003c\/p\u003e\n\u003ca href=\"https:\/\/bluetigerscientific.com\/pages\/contact\" style=\"display:inline-block; max-width:100%; padding:12px 16px; border-radius:6px; background:#245B45; color:white; text-decoration:none; font-weight:600; line-height:1.4;\"\u003eConfirm my vacuum setup\u003c\/a\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0; margin-top:30px; padding-top:20px;\"\u003e\n\u003ch3 style=\"font-size:1.1rem; font-weight:600; margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0; border-radius:8px; margin:0 0 10px; background:white;\"\u003e\u003csummary style=\"cursor:pointer; padding:14px 16px; font-weight:600; list-style-position:inside;\"\u003eDoes VACSTAR control 0020109376 include the controller and a separate VSE 1?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eThe vacuum controller, ceramic sensor and removable WiCo belong to VACSTAR control. The current US scope also lists a 1 m vacuum hose, WH11, OS 1.0 WiCo supply, USB leads and screwdriver. A separate VSE 1 accessory is not promised as included. The manufacturer description calls it an accessory while the table marks emission\/condensate features as present; the manual also depicts receiving hardware. Confirm the exact current assembly for an emissions-critical method. Do not assume either that a separate VSE 1 is supplied or that no condensate\/emission hardware is fitted.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0; border-radius:8px; margin:0 0 10px; background:white;\"\u003e\u003csummary style=\"cursor:pointer; padding:14px 16px; font-weight:600; list-style-position:inside;\"\u003eDoes it deliver 22 L\/min at 2 mbar?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eDo not combine those endpoints. IKA specifies a 22 L\/min maximum pumping rate and 2 mbar ultimate pressure without gas ballast. They do not establish22 L\/min at 2 mbar under a solvent load. Apparatus volume, leaks, hose restrictions, vapour load and method conditions determine actual performance.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0; border-radius:8px; margin:0 0 10px; background:white;\"\u003e\u003csummary style=\"cursor:pointer; padding:14px 16px; font-weight:600; list-style-position:inside;\"\u003eCan it reach 1 mbar because the sensor and control range start at 1 mbar?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eThe stated 1–1,030 mbar sensor range and1 mbar resolution are not the pump’s ultimate-pressure specification. The pump is specified at 2 mbar without gas ballast. The manufacturer lists 1 mbar measurement uncertainty, which is different from resolution and does not guarantee a particular process result.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0; border-radius:8px; margin:0 0 10px; background:white;\"\u003e\u003csummary style=\"cursor:pointer; padding:14px 16px; font-weight:600; list-style-position:inside;\"\u003eCan I pump liquids, corrosive gases or any solvent because it is chemically resistant?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eNo. The manual prohibits liquid pumping, explosive or corrosive gases and explosive atmospheres. Prevent liquid and solid carryover, provide the required liquid\/vapour protection and confirm exact wetted-material compatibility. Chemical-resistant construction and a solvent-library entry do not authorize unrestricted gas or solvent service.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0; border-radius:8px; margin:0 0 10px; background:white;\"\u003e\u003csummary style=\"cursor:pointer; padding:14px 16px; font-weight:600; list-style-position:inside;\"\u003eWhich modes and programs are available, and does the timer work in every mode?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eAutomatic supports boiling-point recognition under suitable stable conditions; Manual sets a pressure target; Pump % selects pumping output; Program supports up to 10 profiles with up to 10 segments each. The manual states the timer is disabled in Automatic and Program modes. Stored solvent data is method assistance, not a universal mixture-identification or compatibility guarantee.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0; border-radius:8px; margin:0 0 10px; background:white;\"\u003e\u003csummary style=\"cursor:pointer; padding:14px 16px; font-weight:600; list-style-position:inside;\"\u003eDo I need this as an extra pump for RV 10 digital pro V-C Complete 0010012821?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eNot by default. That existing Complete package already supplies vacuum equipment. IKA lists the product family as compatible, but this separate pump listing does not establish a need for another pump or a drop-in controller change. Review the existing pump\/controller arrangement, connections and method before selecting a different vacuum source.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0; border-radius:8px; margin:0 0 10px; background:white;\"\u003e\u003csummary style=\"cursor:pointer; padding:14px 16px; font-weight:600; list-style-position:inside;\"\u003eIs a condensate trap enough, and how should the exhaust be handled?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eUpstream separation protects the pump against liquid carryover; downstream condensation manages exhaust vapours. Confirm the actual supplied assembly and additional protection needed for your method. Route an unrestricted, unkinked exhaust line to a suitable fume hood, with the manual’s2 m maximum exhaust-line length. Do not close or throttle the discharge. A condenser does not establish zero emissions or remove ventilation requirements.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0; border-radius:8px; margin:0 0 10px; background:white;\"\u003e\u003csummary style=\"cursor:pointer; padding:14px 16px; font-weight:600; list-style-position:inside;\"\u003eDo I need a PC, and will the pump always stop if the WiCo battery or wireless link fails?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:1rem; line-height:1.7; margin:0 0 14px;\"\u003eA PC or internet connection is not needed for local WiCo operation. Wireless range is building-dependent, up to 150 m per the manual, and regional radio approval applies. Communication loss or battery depletion does not guarantee shutdown: configured timeout and safety settings may allow continued pumping. Set safe behavior for the method and retain accessible station stopping controls. Optional software licenses and cables are not automatically included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53478348980522,"sku":"BTS-0020109376","price":5871.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-vacstar-control-system.webp?v=1793924401"}],"url":"https:\/\/bluetigerscientific.com\/collections\/ika-evaporation-vacuum.oembed","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}