{"title":"Hanna Instruments Probes \u0026 Electrodes","description":"\u003cp\u003eBrowse probes \u0026amp; electrodes from Hanna Instruments. Compare the available products below, or return to the complete brand range.\u003c\/p\u003e","products":[{"product_id":"hanna-hi11310-digital-glass-ph-electrode-with-temperature-sensor-for-lab","title":"Hanna HI11310 Digital Glass pH Electrode with Temperature Sensor for Lab","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; padding: 40px 20px; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333; background: #fff;\"\u003e\n\u003cp style=\"font-size: 1.05rem;\"\u003e\u003cstrong\u003eAchieve precise pH measurements with the Hanna Instruments HI11310 digital glass body pH electrode, engineered for superior performance and seamless integration in laboratory environments.\u003c\/strong\u003e This advanced probe combines a built-in temperature sensor and intelligent microchip technology to ensure reliable and accurate readings across diverse applications.\u003c\/p\u003e\n\u003cdiv style=\"display: block; padding-top: 20px;\"\u003e\n\u003cdiv\u003e\n\u003ch4 style=\"font-weight: 400; margin-bottom: 8px;\"\u003eBuilt-In Microchip\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem;\"\u003eThe integrated microchip stores crucial sensor data, including sensor type, serial number, and comprehensive calibration information such such as date, time, offset, slope, probe condition, and buffers used. This data is automatically retrieved by your Hanna edge® meter when the electrode is connected, allowing for convenient hot-swapping without the need for recalibration. All pH measurements are digitally processed within the electrode itself and then transferred to the meter, effectively eliminating electrical noise issues often associated with traditional high-impedance analog systems, especially in humid conditions or from built-in temperature sensors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch4 style=\"font-weight: 400; margin-bottom: 8px;\"\u003eSpherical Glass Tip\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem;\"\u003eThe unique spherical tip design of the electrode maximizes contact area with your sample, leading to faster response times and enhanced measurement stability. The HI11310 utilizes a high temperature (HT) glass formulation, making it suitable for samples ranging from -5 to 100°C. While standard general-purpose (GP) glass electrodes typically have a resistance of 100 megaohms at 25°C, the HI11310's HT glass starts around 400 megaohms at 25°C, with its resistance decreasing to approximate that of GP glass when exposed to elevated temperatures, ensuring consistent accuracy across its operational range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch4 style=\"font-weight: 400; margin-bottom: 8px;\"\u003eDouble Junction Reference\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem;\"\u003eThis electrode features a double junction design, which includes an internal compartment surrounding the reference wire. This inner compartment contains silver ions in its electrolyte, while the electrolyte in the outer compartment is kept silver-free. This advanced configuration ensures that virtually no silver from the electrode enters your sample, making the HI11310 ideal for measuring samples where silver contamination is undesirable or where the formation of silver precipitates on the junction is a concern.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch4 style=\"font-weight: 400; margin-bottom: 8px;\"\u003eGlass Electrode Body\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem;\"\u003eThe durable glass body of the electrode offers excellent chemical resistance, making it suitable for a broad spectrum of applications. This material is compatible with many non-aqueous solvents and other aggressive chemicals commonly found in laboratories. Furthermore, glass provides inherent resistance to various forms of radiation, such as ultraviolet radiation, contributing to the probe's long-term integrity and performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch4 style=\"font-weight: 400; margin-bottom: 8px;\"\u003eBuilt-In Temperature Sensor\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem;\"\u003eThe HI11310 digital pH probe incorporates a built-in thermistor temperature sensor precisely positioned at the tip of the indicating pH electrode. This strategic placement ensures the temperature reading is as close as possible to the pH sensing membrane, which is vital for accurately compensating for temperature's influence on the membrane potential. By providing highly accurate temperature data, this sensor guarantees truly precise, temperature-compensated pH results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-top: 1px solid #e0e0e0; margin-top: 40px; padding-top: 20px;\"\u003e\n\u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;\"\u003e\n\u003ch3 style=\"font-size: 1.1rem; font-weight: 600; margin: 0 0 16px 0;\"\u003eHI11310 buying questions\u003c\/h3\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich meters does the HI11310 work with?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eIt connects through a 3.5 mm connector designed for Hanna edge® tablet meters. It is a digital smart electrode, not an analog BNC probe, so confirm your meter is an edge model before ordering.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat does the built-in microchip do?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eIt stores the sensor type, serial number and calibration data (date, time, offset, slope, probe condition and buffers used). Your edge meter reads this automatically when the electrode is connected, so you can hot-swap electrodes without recalibrating. Measurements are digitized in the electrode itself, which eliminates the electrical noise issues of high-impedance analog systems.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat samples and temperatures can it handle?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe high-temperature glass tip is rated for samples from -5 to 100 °C across the full pH 0 to 14 range. Hanna lists it for laboratory general purpose and beer applications, and the glass body offers chemical resistance suitable for many non-aqueous solvents.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhy does the double junction matter?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe outer reference compartment is silver-free, so virtually no silver enters your sample. Choose this design when silver contamination is undesirable or silver precipitates could clog the junction.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs the electrode refillable?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eYes. It is a refillable combination pH electrode using KCl 3.5M electrolyte with a single ceramic junction rated at 15-20 µL\/h flow.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes it provide temperature compensation?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eA thermistor temperature sensor is built into the tip, right beside the pH sensing membrane, so temperature compensation tracks the actual sample temperature at the point of measurement.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat are the pressure and cable specifications?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eMaximum pressure is 0.1 bar, and the electrode is supplied with a 1 m (3.3 ft) cable.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat warranty and shipping apply?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eWarranty claims are handled by Hanna Instruments; where a listing does not state a product-specific term, the posted store policy applies a standard 18-month term from Hanna's factory ship date. Orders ship via FedEx from Hanna's fulfillment center in Smithfield, Rhode Island, to U.S. residential or business addresses only (no PO Boxes).\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":50249402188074,"sku":"BTS-HI11310","price":259.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/HI11310-1200x1200__98626.1746710636.jpg?v=1748571885"},{"product_id":"hanna-instruments-hi7698194-0-spare-ph-sensor-for-multiparameter-probes","title":"Hanna Instruments HI7698194-0 Spare pH Sensor for Multiparameter Probes","description":"\u003cdiv data-hs-cos-field=\"content\" data-hs-cos-type=\"inline_rich_text\" data-hs-cos-general-type=\"widget\" style=\"font-family: 'Open Sans', sans-serif; font-weight: 300;\" class=\"hs_cos_wrapper hs_cos_wrapper_widget hs_cos_wrapper_type_inline_rich_text\" id=\"hs_cos_wrapper_widget_12054182691_\"\u003e\n\u003ch4 style=\"font-weight: 400; font-size: 1.05rem;\"\u003e\u003cstrong\u003ePEI Sensor Body\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1.05rem;\"\u003eBuilt for rugged environments, the HI7698194-0 features a PEI (polyetherimide) body that resists chemical exposure and physical impact. Its protective shield around the glass tip helps prevent breakage during field use, making it ideal for demanding applications.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400; font-size: 1.05rem;\"\u003e\u003cstrong\u003eCeramic Double Junction Reference\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1.05rem;\"\u003eThis sensor’s double junction design isolates silver ions within an internal compartment, preventing contamination of the sample. It’s engineered for compatibility with sensitive applications where silver interference or precipitation must be avoided.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400; font-size: 1.05rem;\"\u003e\u003cstrong\u003eColor Coded Sensor\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1.05rem;\"\u003eEach sensor is color coded to match its designated port on the probe, allowing for fast, accurate installation and field replacement using a screw-type connection.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":50777721536810,"sku":"BTS-HI7698194-0","price":244.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/HI-7609829-0__30313.1569522680.jpg?v=1762293656"},{"product_id":"hanna-instruments-hi7698194-multiparameter-probe-for-hi98194-ph-ec-do-temperature","title":"Hanna Instruments HI7698194 Multiparameter Probe for HI98194 (pH\/EC\/DO\/Temperature)","description":"\u003cdiv data-hs-cos-field=\"content\" data-hs-cos-type=\"inline_rich_text\" data-hs-cos-general-type=\"widget\" style=\"font-family: 'Open Sans', sans-serif; font-weight: 300;\" class=\"hs_cos_wrapper hs_cos_wrapper_widget hs_cos_wrapper_type_inline_rich_text\" id=\"hs_cos_wrapper_widget_12052961896_\"\u003e\n\u003ch4 style=\"font-weight: 400; font-size: 1.05rem;\"\u003e\u003cstrong\u003eFeatures at-a-glance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1.05rem;\"\u003e\u003cstrong\u003eWaterproof Protection\u003c\/strong\u003e – Rated IP68, the HI7698194 probe is built for continuous submersion in water, making it ideal for field deployment.\u003c\/p\u003e\n\u003cp style=\"font-size: 1.05rem;\"\u003e\u003cstrong\u003eQuick Connect Digital Probe\u003c\/strong\u003e – A DIN-style quick connect ensures a secure, waterproof link between the probe and the HI98194 meter.\u003c\/p\u003e\n\u003cp style=\"font-size: 1.05rem;\"\u003e\u003cstrong\u003eColor-Coded, Field Replaceable Sensors\u003c\/strong\u003e – Each sensor module uses a screw-type connector and color-coded housing for fast, accurate installation and replacement.\u003c\/p\u003e\n\u003cp style=\"font-size: 1.05rem;\"\u003e\u003cstrong\u003eAuto-sensor Recognition\u003c\/strong\u003e – The probe and meter automatically detect connected sensors, hiding unused parameters from the display and configuration menus.\u003c\/p\u003e\n\u003cp style=\"font-size: 1.05rem;\"\u003e\u003cstrong\u003eAutomatic Temperature Compensation\u003c\/strong\u003e – An integrated temperature sensor enables real-time compensation for pH, conductivity, and dissolved oxygen readings.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400; font-size: 1.05rem;\"\u003e\u003cstrong\u003eAvailable Sensors\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1.05rem;\"\u003e\u003cstrong\u003eHI7698194-0 – Replaceable pH Sensor\u003c\/strong\u003e for use with Hanna multiparameter probes. Features a PEI body, double ceramic junction, and gel-filled Ag\/AgCl reference with a glass sensing tip. Color-coded for easy installation.\u003c\/p\u003e\n\u003cp style=\"font-size: 1.05rem;\"\u003e\u003cstrong\u003eHI7698194-1 – Replaceable pH\/ORP Sensor\u003c\/strong\u003e with PEI housing and dual ceramic junction. Combines a glass pH tip with a platinum ORP pin. Color-coded for seamless integration with the probe.\u003c\/p\u003e\n\u003cp style=\"font-size: 1.05rem;\"\u003e\u003cstrong\u003eHI7698194-2 – Galvanic DO Membrane Sensor\u003c\/strong\u003e with ABS body and twist-on HDPE membrane caps. Contains a silver cathode and zinc anode. Built for easy maintenance and color-coded for quick replacement.\u003c\/p\u003e\n\u003cp style=\"font-size: 1.05rem;\"\u003e\u003cstrong\u003eHI7698194-3 – 4-Ring Conductivity Sensor\u003c\/strong\u003e featuring an ABS body and AISI 316 stainless steel electrodes. Designed to resist polarization and fouling. Color-coded for fast, accurate installation.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"4m Cable (13')","offer_id":50777744474410,"sku":"BTS-HI7698194","price":1384.99,"currency_code":"USD","in_stock":true},{"title":"10m Cable (32.8')","offer_id":50777744507178,"sku":"BTS-HI7698194\/10","price":1534.99,"currency_code":"USD","in_stock":true},{"title":"20m Cable (65.6')","offer_id":50777744539946,"sku":"BTS-HI7698194\/20","price":1684.99,"currency_code":"USD","in_stock":true},{"title":"40m Cable (131.2')","offer_id":50777744572714,"sku":"BTS-HI7698194\/40","price":2009.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/hi7698194__25005.1569519477.jpg?v=1762294037"},{"product_id":"hanna-instruments-hi5148b-silver-billet-electrode-for-halide-titration","title":"Hanna Instruments HI5148B Silver Billet Electrode for Halide Titration","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; padding: 40px 20px; font-family: 'Open Sans', sans-serif; font-weight: 300;\"\u003e\n\u003c!-- Simple side-by-side section: Image left, text right --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px;\"\u003e\n\u003c!-- Image --\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: 300px; order: 1;\"\u003e\u003cimg style=\"width: 100%; height: auto; object-fit: contain; border-radius: 8px;\" alt=\"Close-up of HI5148B silver billet electrode tip with CPS sleeve\" src=\"https:\/\/cdn2.hubspot.net\/hubfs\/2134380\/003-blog\/Blog%20Images\/HI5148B_tip-720x720-8ca1067f-6e78-43d2-afbf-85a7c09b2066.jpg?width=600\"\u003e\u003c\/div\u003e\n\u003c!-- Text Content --\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: 300px; order: 2;\"\u003e\n\u003ch3 style=\"font-weight: 400; font-size: 2.2rem; margin-bottom: 20px; text-align: left;\"\u003eHI5148B Silver Billet Electrode for Precise Halide Titration\u003c\/h3\u003e\n\u003cp style=\"font-size: 1.05rem; line-height: 1.75; margin-bottom: 20px;\"\u003e\u003cstrong\u003eCost-effective alternative\u003c\/strong\u003e to ion-selective electrodes: The HI5148B silver billet electrode avoids the softening and degradation issues common with compressed pellet ISEs during extended immersion, making it ideal for high-volume chloride titration and halide analysis in challenging samples.\u003c\/p\u003e\n\u003ch4 style=\"color: #005eb8; font-size: 1.55rem; margin: 24px 0 12px;\"\u003eRobust Silver Billet Sensing Element\u003c\/h4\u003e\n\u003cp style=\"font-size: 1.05rem; line-height: 1.75; margin-bottom: 20px;\"\u003eThis solid silver billet tip generates a reliable mV potential through direct reaction with halides, ensuring precise endpoint detection in potentiometric titrations with silver nitrate for accurate salt content determination.\u003c\/p\u003e\n\u003ch4 style=\"color: #005eb8; font-size: 1.55rem; margin: 24px 0 12px;\"\u003eClogging Prevention System (CPS™) with Movable Sleeve\u003c\/h4\u003e\n\u003cp style=\"font-size: 1.05rem; line-height: 1.75; margin-bottom: 20px;\"\u003eThe polyethylene sleeve over ground glass junction resists dirt buildup and maintains optimal electrolyte flow, extending electrode lifespan up to 20 times longer than traditional designs in viscous or particulate-laden solutions.\u003c\/p\u003e\n\u003ch4 style=\"color: #005eb8; font-size: 1.55rem; margin: 24px 0 12px;\"\u003eRefillable Double Junction Configuration\u003c\/h4\u003e\n\u003cp style=\"font-size: 1.05rem; line-height: 1.75;\"\u003eAs a refillable combination electrode, it allows selection of appropriate fill solutions tailored to your titration method and easy replacement if contamination occurs, supporting versatile and long-term use in laboratory settings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":50975570166058,"sku":"BTS-HI5148B","price":409.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/silver-billet-electrode-hi5148b__55126.1565358799.jpg?v=1766280796"},{"product_id":"hanna-instruments-hi1048b-ph-electrode-with-cps™-clogging-prevention-bnc","title":"Hanna Instruments HI1048B pH Electrode with CPS™ Clogging Prevention \u0026 BNC","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; padding: 40px 20px; font-family: 'Open Sans', sans-serif; font-weight: 300;\"\u003e\n  \u003c!-- Introductory text block --\u003e\n  \u003cdiv style=\"text-align: center; margin-bottom: 40px;\"\u003e\n    \u003cp style=\"font-size: 1.05rem; line-height: 1.75; max-width: 980px; margin: 0 auto;\"\u003e\u003cstrong\u003eHanna Instruments\u003c\/strong\u003e offers a comprehensive range of pH electrodes engineered for specific applications and sample types. Critical design elements include the sensing glass formulation, bulb geometry, body material, junction type, reference configuration, and electrolyte composition—all optimized to deliver accurate and reliable pH measurements.\u003c\/p\u003e\n    \u003cp style=\"font-size: 1.05rem; line-height: 1.75; max-width: 980px; margin: 20px auto 0;\"\u003eThe HI1048B pH electrode for wine and juice features general purpose (GP) glass, a spherical bulb, durable glass body, innovative CPS™ sleeve junction, double junction reference, and refillable 3.5M KCl electrolyte. This combination makes it exceptionally suited for measuring pH in high-solids samples such as wine must, fruit juice, suspensions, and other viscous matrices that typically challenge standard electrodes.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003c!-- Divider --\u003e\n  \u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"max-width: 1400px; margin: 0 auto; padding: 40px 20px; font-family: 'Open Sans', sans-serif; font-weight: 300;\"\u003e\n  \u003c!-- Detailed features section --\u003e\n  \u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n    \u003c!-- Text content --\u003e\n    \u003cdiv style=\"flex: 1 1 500px; min-width: 300px; order: 1;\"\u003e\n      \u003ch4 style=\"font-weight: 400; font-size: 1.55rem; margin: 0 0 12px; color: #3772FF;\"\u003eGeneral Purpose Glass Formulation\u003c\/h4\u003e\n      \u003cp style=\"font-size: 1.05rem; line-height: 1.75;\"\u003eGeneral purpose (GP) glass provides a versatile and reliable sensing membrane ideal for routine pH measurement across a broad range of applications. Exhibiting approximately 100 megaohms resistance at 25°C, it performs optimally at ambient conditions. The HI1048B effectively measures samples with temperatures ranging from -5 to 60°C (23 to 140°F), covering typical wine and juice processing environments.\u003c\/p\u003e\n\n      \u003ch4 style=\"font-weight: 400; font-size: 1.55rem; margin: 32px 0 12px; color: #3772FF;\"\u003eSpherical Glass Tip\u003c\/h4\u003e\n      \u003cp style=\"font-size: 1.05rem; line-height: 1.75;\"\u003eThe spherical bulb design maximizes surface contact with the sample, enabling faster electrode response and superior stability—critical advantages when monitoring pH in wine must and fruit juices where rapid, accurate readings support quality control decisions.\u003c\/p\u003e\n\n      \u003ch4 style=\"font-weight: 400; font-size: 1.55rem; margin: 32px 0 12px; color: #3772FF;\"\u003eCPS™ Sleeve Junction\u003c\/h4\u003e\n      \u003cp style=\"font-size: 1.05rem; line-height: 1.75;\"\u003eClogging Prevention System (CPS™) represents a breakthrough for pH electrodes used in high-solids samples. By pairing ground glass porosity with a PTFE sleeve, it maintains consistent electrolyte flow while repelling particulates and debris. This innovative junction design allows the HI1048B to resist fouling up to 20 times longer than conventional ceramic junctions, dramatically reducing maintenance and extending operational life in challenging wine and juice matrices.\u003c\/p\u003e\n\n      \u003ch4 style=\"font-weight: 400; font-size: 1.55rem; margin: 32px 0 12px; color: #3772FF;\"\u003eDouble Junction Reference\u003c\/h4\u003e\n      \u003cp style=\"font-size: 1.05rem; line-height: 1.75;\"\u003eThe double junction construction features an internal compartment that isolates the Ag\/AgCl reference wire, preventing silver ion migration into the sample. This proves essential in applications containing sulfides or where silver precipitation could otherwise block the junction, ensuring stable, drift-free pH readings over extended use.\u003c\/p\u003e\n\n      \u003ch4 style=\"font-weight: 400; font-size: 1.55rem; margin: 32px 0 12px; color: #3772FF;\"\u003eRefillable Design\u003c\/h4\u003e\n      \u003cp style=\"font-size: 1.05rem; line-height: 1.75;\"\u003eAs a refillable double junction pH electrode, the HI1048B utilizes silver-free HI7082 3.5M KCl electrolyte. Users can easily replenish or replace the fill solution if contamination occurs, providing flexibility and prolonged service life across multiple testing cycles.\u003c\/p\u003e\n\n      \u003ch4 style=\"font-weight: 400; font-size: 1.55rem; margin: 32px 0 12px; color: #3772FF;\"\u003eGlass Body Construction\u003c\/h4\u003e\n      \u003cp style=\"font-size: 1.05rem; line-height: 1.75;\"\u003eThe robust glass body resists aggressive chemicals, facilitates easy cleaning, and enables rapid thermal equilibration with the internal reference electrolyte. Faster temperature stabilization translates to more consistent reference potential and dependable pH measurements in varying lab conditions.\u003c\/p\u003e\n\n      \u003ch4 style=\"font-weight: 400; font-size: 1.55rem; margin: 32px 0 12px; color: #3772FF;\"\u003eBNC Connector\u003c\/h4\u003e\n      \u003cp style=\"font-size: 1.05rem; line-height: 1.75;\"\u003eEquipped with a universal BNC connector, the HI1048B connects seamlessly to any pH meter with a female BNC input, eliminating the need for proprietary adapters and ensuring broad compatibility across instrumentation brands.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Final comparison section (no bottom border) --\u003e\n  \u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px;\"\u003e\n    \u003c!-- Centered image with heading --\u003e\n    \u003cdiv style=\"flex: 1 1 100%; text-align: center;\"\u003e\n      \u003cimg src=\"https:\/\/cdn2.hubspot.net\/hubfs\/2134380\/001-website\/images\/singlevsdoublejunction.jpg?width=800\" alt=\"Single junction versus double junction pH electrode comparison diagram\" style=\"width: 100%; max-width: 800px; height: auto; object-fit: contain; border-radius: 8px;\"\u003e\n      \u003ch4 style=\"font-weight: 400; font-size: 1.55rem; margin: 24px 0 12px; color: #3772FF; text-align: center;\"\u003eSingle Junction Versus Double Junction pH Electrodes\u003c\/h4\u003e\n    \u003c\/div\u003e\n    \u003c!-- Full-width explanatory text --\u003e\n    \u003cdiv style=\"flex: 1 1 100%;\"\u003e\n      \u003cp style=\"font-size: 1.05rem; line-height: 1.75; max-width: 980px; margin: 0 auto 20px;\"\u003e\u003cstrong\u003eTraditional single junction electrodes\u003c\/strong\u003e have only one barrier between the internal reference wire and external sample. Under challenging conditions—high pressure, extreme temperatures, strongly acidic or alkaline solutions—the electrolyte flow can reverse, allowing sample ingress that contaminates the reference and leads to complete failure.\u003c\/p\u003e\n      \u003cp style=\"font-size: 1.05rem; line-height: 1.75; max-width: 980px; margin: 0 auto 20px;\"\u003eSilver chloride precipitation poses another common issue, particularly in samples containing Tris buffers or heavy metals. When AgCl forms on the junction face, it causes blocked flow and erratic, drifting readings.\u003c\/p\u003e\n      \u003cp style=\"font-size: 1.05rem; line-height: 1.75; max-width: 980px; margin: 0 auto;\"\u003eHanna’s double junction system adds an intermediate compartment that physically separates the reference from potential contaminants. The silver-free outer electrolyte eliminates precipitate formation, significantly reducing clogging risk and delivering far more reliable, stable performance—even in the most demanding wine, juice, and high-solids applications.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":50987309826346,"sku":"BTS-HI1048B","price":334.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/hi1048b-hi1048p_2100x2100_300_cmyk--down__47277.1559321299.jpg?v=1766613957"},{"product_id":"hanna-instruments-hi2001-orp-electrode-for-process-control-monitoring","title":"Hanna Instruments HI2001 ORP Electrode for Process Control \u0026 Monitoring","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; font-family: 'Open Sans', sans-serif; font-weight: 300; font-size: 1.05rem;\"\u003e\n\u003c!-- Text-Only Major Section with Internal Headings --\u003e\n\u003cdiv style=\"padding-bottom: 40px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eRobust and reliable design\u003c\/strong\u003e features a spherical glass bulb, durable PVDF body, and advanced PTFE junction filled with polymer electrolyte for superior performance in demanding industrial applications.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400;\"\u003eSpherical Glass Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWide-contact spherical bulb\u003c\/strong\u003e ensures extensive surface interaction with the measured sample, delivering rapid response times and enhanced measurement stability. The protective PEI sleeve adds excellent resistance to mechanical impact and stress.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400;\"\u003ePVDF Body\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eChemically resistant PVDF construction\u003c\/strong\u003e withstands aggressive chemicals, solvents, abrasion, and mechanical forces. This food-safe plastic also resists ultraviolet light, nuclear radiation, and fungal contamination for long-term durability.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400;\"\u003ePTFE Junction\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eHydrophobic PTFE diaphragm\u003c\/strong\u003e is ideal for electrodes with polymer electrolytes. Its controlled porosity reduces clogging risks while leveraging exceptional chemical resistance, making it a preferred choice across industrial ORP monitoring applications.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400;\"\u003eDouble Junction Reference\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eSilver-free double junction technology\u003c\/strong\u003e incorporates an internal compartment with Ag\/AgCl reference wire surrounded by silver-containing electrolyte. The external electrolyte remains silver-free, preventing silver precipitation or contamination in sensitive samples.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400;\"\u003eBNC Connector\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal BNC connection\u003c\/strong\u003e provides seamless compatibility with any pH or ORP meter equipped with a standard female BNC input, simplifying integration and replacement.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400;\"\u003eExternal Thread\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile mounting threads\u003c\/strong\u003e include a ½\" NPT front thread for secure in-line installation and a ¾\" back thread for reliable submersion or immersion mounting options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-top: 1px solid #e0e0e0; margin-top: 40px; padding-top: 20px;\"\u003e\n\u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;\"\u003e\n\u003ch3 style=\"font-size: 1.1rem; font-weight: 600; margin: 0 0 16px 0;\"\u003eHI2001 buying questions\u003c\/h3\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat is the HI2001 designed for?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eIt is an ORP electrode built for process control and monitoring in demanding industrial environments, with a spherical glass bulb, PVDF body and PTFE junction with polymer electrolyte.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWill it connect to my meter?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eIt uses a universal BNC connection, so it works with any pH or ORP meter that has a standard female BNC input, which makes integration and replacement straightforward.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow can it be mounted?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eA ½\" NPT front thread supports secure in-line installation, and a ¾\" back thread supports submersion or immersion mounting.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat pressure and temperature can it handle?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eIt is rated to a maximum pressure of 6 bar (87 psi) and a recommended operating temperature of -5 to 80 °C.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhy the PTFE junction and polymer electrolyte?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe hydrophobic PTFE diaphragm has controlled porosity that reduces clogging risk and offers strong chemical resistance, which suits continuous industrial ORP monitoring.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhy does the double junction design matter?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe external electrolyte is silver-free, which prevents silver precipitation or contamination in sensitive samples.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow durable is the body?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe food-safe PVDF body resists aggressive chemicals, solvents, abrasion, ultraviolet light and fungal contamination, and the PEI sleeve protects the glass bulb from mechanical impact.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat cable and dimensions does it have?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe body is 86 mm (3.4\") long and it is supplied with a 3 m (9.8 ft) cable.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat warranty and shipping apply?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eWarranty claims are handled by Hanna Instruments; where a listing does not state a product-specific term, the posted store policy applies a standard 18-month term from Hanna's factory ship date. Orders ship via FedEx from Hanna's fulfillment center in Smithfield, Rhode Island, to U.S. residential or business addresses only (no PO Boxes).\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":50994439553322,"sku":"BTS-HI2001","price":284.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/hi2001_orp_electrode__91674.1566572892.jpg?v=1766863224"},{"product_id":"hanna-instruments-hi1001-ph-electrode-for-process-control-monitoring","title":"Hanna Instruments HI1001 pH Electrode for Process Control \u0026 Monitoring","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; font-family: 'Open Sans', sans-serif; font-weight: 300; font-size: 1.05rem;\"\u003e\n\u003c!-- Text-Only Major Section with Internal Headings --\u003e\n\u003cdiv style=\"padding-bottom: 40px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEngineered for demanding process environments\u003c\/strong\u003e, the HI1001 features a spherical glass bulb, rugged PVDF body, and advanced PTFE junction with polymer electrolyte for reliable continuous pH monitoring.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400;\"\u003eSpherical Glass Tip\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized spherical sensing bulb\u003c\/strong\u003e provides extensive contact area with the sample, enabling rapid response times and superior measurement stability. A protective PEI sleeve enhances resistance to mechanical shock and stress.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400;\"\u003ePVDF Body\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eDurable PVDF construction\u003c\/strong\u003e offers exceptional resistance to aggressive chemicals, solvents, abrasion, and mechanical forces. This advanced plastic also withstands ultraviolet and nuclear radiation while preventing fungal growth.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400;\"\u003ePTFE Junction\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eClog-resistant PTFE diaphragm\u003c\/strong\u003e is specifically suited for polymer electrolyte electrodes. Its hydrophobic nature and selectable porosity minimize blockage, delivering reliable performance in harsh industrial settings where PTFE is the material of choice.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400;\"\u003eDouble Junction Reference\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eContamination-free double junction design\u003c\/strong\u003e isolates the Ag\/AgCl reference wire in an internal silver-containing compartment. The external electrolyte remains silver-free, preventing silver precipitation and enabling accurate measurements in sensitive applications.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400;\"\u003eBNC Connector\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eStandard BNC connectivity\u003c\/strong\u003e ensures universal compatibility with any process pH meter featuring a female BNC input for straightforward integration and replacement.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400;\"\u003eExternal Thread\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible installation threads\u003c\/strong\u003e include a ½\" NPT front thread for secure in-line mounting and a ¾\" rear thread for submersion or immersion applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":50994484805930,"sku":"BTS-HI1001","price":252.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/hi1001_1200x1200_72_rgb__22304.1559321303.jpg?v=1766864608"},{"product_id":"hanna-instruments-hi7640-58-optical-do-process-smart-probe","title":"Hanna Instruments HI7640‑58 Optical DO Process Smart Probe","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; font-family: 'Open Sans', sans-serif; font-weight: 300; font-size: 1.05rem;\"\u003e\n\u003c!-- Text-Only Major Section with Detailed Content --\u003e\n\u003cdiv style=\"padding-bottom: 40px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for demanding dissolved oxygen monitoring\u003c\/strong\u003e in aeration basins, treatment ponds, and process tanks, the HI764833 optical DO probe delivers precise control of oxygen transfer efficiency. Versatile mounting options include direct submersion via ¾\" NPT threads or secure in-line installation in a flow cell using the front sensor threads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtended reach capability\u003c\/strong\u003e is achieved with optional extension cables, allowing reliable signal transmission over distances up to 50 meters (164 feet) between the probe and connected controller.\u003c\/p\u003e\n\u003ch4 style=\"font-weight: 400;\"\u003ePrinciple of Operation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced fluorescence quenching technology\u003c\/strong\u003e utilizes an immobilized platinum-based luminophore excited by a blue LED, emitting red light that is quenched by dissolved oxygen molecules. In the absence of oxygen, luminescence lifetime is longest; increasing oxygen levels shorten this lifetime proportionally.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccurate concentration calculation\u003c\/strong\u003e is derived from the inverse relationship between luminescence intensity\/lifetime and oxygen presence. A high-sensitivity photodetector measures the luminescence lifetime, enabling the controller to display results as % saturation or mg\/L (ppm) dissolved oxygen with exceptional precision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-term stability and minimal drift\u003c\/strong\u003e are maintained through internal reference signal compensation for optical component aging. This innovative design ensures consistently accurate readings over extended periods with significantly reduced calibration frequency compared to traditional polarographic sensors.\u003c\/p\u003e\n\u003cul style=\"line-height: 1.6; padding-left: 1.2rem;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-calibrated Smart Cap\u003c\/strong\u003e stores factory calibration data for instant plug-and-play accuracy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual ¾\" NPT threads\u003c\/strong\u003e enable flexible submersion or flow-through installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated temperature sensor\u003c\/strong\u003e provides automatic compensation for precise DO measurements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital intelligence\u003c\/strong\u003e stores probe model, serial number, firmware version, and full calibration history\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVirtually maintenance-free\u003c\/strong\u003e operation — no electrolyte refills or membrane replacements required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow-independent performance\u003c\/strong\u003e delivers reliable results even in static or low-flow conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid response time\u003c\/strong\u003e for real-time process control and optimization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior low-oxygen stability\u003c\/strong\u003e ensures accurate readings at near-zero concentrations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Optical DO process smart probe-supplied with DIN connector (without cable)","offer_id":50994495062314,"sku":"HI7640‑58-00","price":1944.99,"currency_code":"USD","in_stock":true},{"title":"Optical DO process smart probe with 5-meter cable","offer_id":50994495095082,"sku":"HI7640‑58-05","price":2094.99,"currency_code":"USD","in_stock":true},{"title":"Optical DO process smart probe with 10-meter cable","offer_id":50994495127850,"sku":"HI7640‑58-10","price":2144.99,"currency_code":"USD","in_stock":true},{"title":"Optical DO process smart probe with 15-meter cable","offer_id":50994495160618,"sku":"HI7640‑58-15","price":2319.99,"currency_code":"USD","in_stock":true},{"title":"Optical DO process smart probe with 25-meter cable","offer_id":50994495193386,"sku":"HI7640‑58-25","price":2469.99,"currency_code":"USD","in_stock":true},{"title":"Optical DO process smart probe with 50-meter cable","offer_id":50994495226154,"sku":"HI7640‑58-50","price":2844.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/HI7640-5805_720x720__10711.1671570514.jpg?v=1766864968"},{"product_id":"hanna-instruments-hi11313-refillable-glass-body-ph-electrode-with-quick-connect-din-connector","title":"Hanna Instruments HI11313 Refillable Glass Body pH Electrode with Quick Connect DIN Connector","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333; background: #fff;\"\u003e\n\n  \u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n    \u003cdiv style=\"flex: 1 1 500px; min-width: 300px;\"\u003e\n      \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eHanna’s HI11313 refillable glass pH electrode\u003c\/strong\u003e is built for reliable, general-purpose measurements, combining high-temperature (HT) glass, a spherical sensing bulb, glass body, single ceramic frit, and a double-junction reference system. Filled with 3.5M KCl electrolyte, it provides stable, accurate pH readings across a wide range of laboratory applications.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n    \u003cdiv style=\"flex: 1 1 500px; min-width: 300px;\"\u003e\n      \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eHigh Temperature Glass Formulation\u003c\/strong\u003e\u003c\/h4\u003e\n      \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eHigh-temperature glass improves electrode durability\u003c\/strong\u003e by resisting thermal stress that can shorten the life of standard pH bulbs. General-purpose glass typically measures around 100 megaohms at 25 °C, while HT glass is closer to 400 megaohms at 25 °C, maintaining stability as temperatures rise. The HI11313 supports measurements from 0 to 100 °C, making it suitable for demanding sample conditions.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1 1 500px; min-width: 300px;\"\u003e\n      \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eSpherical Glass Tip\u003c\/strong\u003e\u003c\/h4\u003e\n      \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eThe spherical sensing bulb is ideal for general-purpose pH testing\u003c\/strong\u003e, offering consistent contact with a wide variety of sample types. While conical tips are used for penetration and flat tips for surface measurements, the spherical design provides broad compatibility and dependable performance in routine laboratory work.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n    \u003cdiv style=\"flex: 1 1 500px; min-width: 300px;\"\u003e\n      \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eGlass Body Construction\u003c\/strong\u003e\u003c\/h4\u003e\n      \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eThe glass body is well-suited for laboratory environments\u003c\/strong\u003e, offering chemical resistance and easy cleaning for consistent performance. Glass also promotes rapid heat transfer to the internal reference electrolyte, helping the reference potential stabilize quickly for steady, repeatable readings.\u003c\/p\u003e\n\n      \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eSingle Ceramic Double Junction Reference\u003c\/strong\u003e\u003c\/h4\u003e\n      \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eThe HI11313 uses a double-junction reference with a single ceramic frit\u003c\/strong\u003e to maintain a steady ion flow through the junction. The ceramic material integrates cleanly with the glass body and provides a typical flow rate of 15–20 µL\/hour, supporting stable readings while reducing clogging and contamination in challenging samples.\u003c\/p\u003e\n\n      \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eRefillable Design\u003c\/strong\u003e\u003c\/h4\u003e\n      \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eThis electrode is refillable with HI7082 3.5M KCl solution\u003c\/strong\u003e, a silver-free electrolyte suited to double-junction designs. Without silver present, the risk of silver chloride buildup at the junction is minimized, helping prevent drift and ensuring long-term measurement reliability.\u003c\/p\u003e\n\n      \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eQuick Connect DIN Connector\u003c\/strong\u003e\u003c\/h4\u003e\n      \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eThe HI11313 features a Quick Connect DIN interface\u003c\/strong\u003e for fast, secure attachment to compatible Hanna meters such as the HI98190. This proprietary connector simplifies installation and removal while ensuring a stable electrical connection for accurate pH measurement.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px;\"\u003e\n    \u003cdiv style=\"flex: 1 1 500px; min-width: 300px;\"\u003e\n      \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eSingle Junction Versus Double Junction pH Electrodes\u003c\/strong\u003e\u003c\/h4\u003e\n      \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eSingle-junction electrodes typically use silver-containing fill solutions\u003c\/strong\u003e such as HI7071 (3.5M KCl + AgCl). Under harsh conditions—high pressure, high temperature, or extreme pH—sample solution can migrate into the reference compartment, contaminating the electrode and causing unstable readings.\u003c\/p\u003e\n      \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eDouble-junction electrodes add an intermediate electrolyte chamber\u003c\/strong\u003e that physically separates the reference element from the sample. This design reduces contamination risk and minimizes silver chloride precipitation, helping prevent junction clogging and improving long-term stability in samples containing Tris buffers or heavy metals.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1 1 500px; min-width: 300px; text-align: center;\"\u003e\n      \u003cimg src=\"https:\/\/cdn2.hubspot.net\/hubfs\/2134380\/001-website\/images\/singlevsdoublejunction.jpg\" alt=\"Single Junction Versus Double Junction pH Electrodes\" style=\"width: 100%; height: auto; object-fit: contain; border-radius: 8px;\"\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":52092335292714,"sku":"BTS-HI11313","price":224.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/hi11310_2_1__69457.1559321278.jpg?v=1784314546"},{"product_id":"hanna-instruments-hi12963-titanium-body-ph-electrode-for-wastewater-with-quick-connect-din-connector","title":"Hanna Instruments HI12963 Titanium Body pH Electrode for Wastewater with Quick Connect DIN Connector","description":"\u003csection style=\"width: 100%; display: flex; justify-content: center; padding: 40px 20px; box-sizing: border-box; font-family: 'Open Sans', sans-serif; font-weight: 300;\"\u003e\n  \u003cdiv style=\"max-width: 1400px; width: 100%; display: flex; flex-direction: column; gap: 40px;\"\u003e\n\n    \u003c!-- Section 1: Overview --\u003e\n    \u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 30px;\"\u003e\n      \u003cdiv style=\"flex: 1 1 500px; min-width: 300px;\"\u003e\n        \u003cp\u003e\n          \u003cstrong\u003eHanna’s HI12963 titanium‑body pH electrode\u003c\/strong\u003e is engineered for demanding wastewater and environmental applications, combining general‑purpose (GP) glass, a spherical sensing bulb, durable titanium construction, and a renewable cloth junction with gel electrolyte. This design supports stable, clog‑resistant performance across industrial, municipal, and environmental pH monitoring.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Section 2: GP Glass + Spherical Bulb --\u003e\n    \u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 30px;\"\u003e\n      \u003cdiv style=\"flex: 1 1 500px; min-width: 300px;\"\u003e\n        \u003ch4 style=\"font-weight: 600; margin-bottom: 10px;\"\u003eGeneral Purpose Glass Formulation\u003c\/h4\u003e\n        \u003cp\u003e\n          \u003cstrong\u003eGeneral‑purpose (GP) glass provides reliable performance\u003c\/strong\u003e for routine pH measurements at ambient temperatures. GP glass typically has a resistance of about 100 megaohms at 25 °C and is well‑suited for samples between 0 and 80 °C, making the HI12963 ideal for everyday wastewater and environmental testing.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"flex: 1 1 500px; min-width: 300px;\"\u003e\n        \u003ch4 style=\"font-weight: 600; margin-bottom: 10px;\"\u003eSpherical Bulb\u003c\/h4\u003e\n        \u003cp\u003e\n          \u003cstrong\u003eThe spherical sensing bulb is optimized for general‑purpose use\u003c\/strong\u003e, providing consistent contact with a wide range of sample types. While conical tips are used for penetration and flat tips for surface measurements, the spherical design offers broad compatibility and dependable performance in routine applications.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Section 3: Titanium Body + Cloth Junction + DIN --\u003e\n    \u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 30px;\"\u003e\n      \u003cdiv style=\"flex: 1 1 500px; min-width: 300px;\"\u003e\n        \u003ch4 style=\"font-weight: 600; margin-bottom: 10px;\"\u003eTitanium Body\u003c\/h4\u003e\n        \u003cp\u003e\n          \u003cstrong\u003eThe titanium body enhances durability and measurement stability\u003c\/strong\u003e by providing strong corrosion resistance and improved immunity to electrostatic and magnetic interference. This makes the HI12963 particularly effective in harsh wastewater environments and high‑conductivity samples.\n        \u003c\/p\u003e\n\n        \u003ch4 style=\"font-weight: 600; margin: 20px 0 10px;\"\u003eCloth Junction\u003c\/h4\u003e\n        \u003cp\u003e\n          \u003cstrong\u003eThe renewable cloth junction supports long‑term, clog‑resistant performance\u003c\/strong\u003e in samples containing solids or heavy contamination. As the cloth is pulled to expose fresh material, the junction is renewed, helping maintain stable readings even in challenging wastewater conditions.\n        \u003c\/p\u003e\n\n        \u003ch4 style=\"font-weight: 600; margin: 20px 0 10px;\"\u003eQuick Connect DIN Connector\u003c\/h4\u003e\n        \u003cp\u003e\n          \u003cstrong\u003eThe HI12963 uses a Quick Connect DIN interface\u003c\/strong\u003e for fast, secure attachment to compatible Hanna meters such as the HI98190 and HI991001. This proprietary connector simplifies installation and ensures a stable electrical connection for accurate pH measurement.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/section\u003e\n","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":52092395815210,"sku":"BTS-HI12963","price":274.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/hi12963_2100x2100_300_cmyk__31697.1559321281.jpg?v=1784315212"},{"product_id":"hanna-instruments-hi12300-digital-pei-body-ph-electrode-for-field-applications","title":"Hanna Instruments HI12300 Digital PEI Body pH Electrode for Field Applications","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333; background: #fff;\"\u003e\n\n  \u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n    \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eBuilt-In Microchip\u003c\/strong\u003e\u003c\/h4\u003e\n    \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eOnboard digital intelligence\u003c\/strong\u003e stores sensor type, serial number, and calibration data including date, time, offset, slope, probe condition, and buffers used. When the HI12300 is connected to a Hanna edge® meter, this information is retrieved automatically so probes can be swapped without recalibration. All pH measurements occur inside the electrode and are sent digitally to the meter, reducing electrical noise that can appear with analog systems, built-in temperature sensors, or humid field conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n    \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eSpherical Glass Tip\u003c\/strong\u003e\u003c\/h4\u003e\n    \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eA wide-contact spherical bulb\u003c\/strong\u003e increases sample surface area for faster response and more stable readings. The general-purpose glass formulation has a resistance of about 100 megaohms, which is optimized for ambient temperatures. High- or low-temperature glass used at room temperature can slow response or shorten electrode life.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n    \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eDouble Junction Reference\u003c\/strong\u003e\u003c\/h4\u003e\n    \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eSilver stays isolated from the sample\u003c\/strong\u003e because the Ag\/AgCl reference wire sits in an inner compartment while the outer electrolyte remains silver-free. Virtually no silver ions enter the measured solution, making the HI12300 suitable where silver contamination is undesirable or silver precipitates are likely to form at the junction.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n    \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003ePEI Electrode Body\u003c\/strong\u003e\u003c\/h4\u003e\n    \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eRugged PEI (polyetherimide) construction\u003c\/strong\u003e delivers the chemical resistance of glass in an unbreakable plastic housing built for field and industrial use. Shielding around the spherical glass tip helps prevent breakage from accidental bumps or drops, and the PEI body resists many harsh chemicals.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv\u003e\n    \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eBuilt-In Temperature Sensor\u003c\/strong\u003e\u003c\/h4\u003e\n    \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eA thermistor in the sensing tip\u003c\/strong\u003e provides a high-accuracy temperature reading as close as possible to the pH glass. That proximity allows proper compensation for temperature effects on membrane potential, producing reliable temperature-compensated pH results with the HI12300 digital PEI body electrode.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":52422846480682,"sku":null,"price":164.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/digital-pei-body-ph-electrode-for-field-applications-hi12300__86451.1559321280.webp?v=1787943162"},{"product_id":"hi10x6-x8xx-ph-temperature-industrial-smart-probe","title":"Hanna HI1006 \/ HI1016 Industrial pH \u0026 Temperature Smart Probe for HI520 \u0026 HI510","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333; background: #fff;\"\u003e\n\n  \u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n    \u003cdiv style=\"flex: 1 1 500px; min-width: 300px; text-align: center;\"\u003e\n      \u003cimg src=\"https:\/\/cdn2.hubspot.net\/hubfs\/2134380\/001-website\/images\/HI1006-1805_standing_v2_720x720.jpg?width=720\u0026amp;height=720\u0026amp;name=HI1006-1805_standing_v2_720x720.jpg\" alt=\"Hanna HI10x6 industrial pH and temperature smart probe\" style=\"width: 100%; max-width: 560px; height: auto; object-fit: contain; border-radius: 8px;\"\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1 1 500px; min-width: 300px;\"\u003e\n      \u003ch3 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eDigital pH Smart Probe for Continuous Process Control\u003c\/strong\u003e\u003c\/h3\u003e\n      \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eBuilt for around-the-clock monitoring\u003c\/strong\u003e, this industrial probe reads pH and temperature together and sends both to your controller as a clean digital signal. It plugs directly into the Hanna HI510 and HI520 Universal Process Controllers, which identify the probe automatically the moment it's connected.\u003c\/p\u003e\n      \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eCalibration travels with the probe.\u003c\/strong\u003e Model, serial number, firmware, and calibration data are stored in the probe itself, so you can calibrate at the bench and install in the field without recalibrating at the controller.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n    \u003cdiv style=\"flex: 1 1 500px; min-width: 300px;\"\u003e\n      \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eWhere It's Used\u003c\/strong\u003e\u003c\/h4\u003e\n      \u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n        \u003ctable style=\"width: 100%; min-width: 300px; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 1rem;\"\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e0e0e0;\"\u003eMunicipal Wastewater Treatment\u003c\/td\u003e\u003c\/tr\u003e\n            \u003ctr style=\"background: #f9f9f9;\"\u003e\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e0e0e0;\"\u003eIndustrial Effluent and Discharge Compliance\u003c\/td\u003e\u003c\/tr\u003e\n            \u003ctr\u003e\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e0e0e0;\"\u003epH Neutralization and Holding Tanks\u003c\/td\u003e\u003c\/tr\u003e\n            \u003ctr style=\"background: #f9f9f9;\"\u003e\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e0e0e0;\"\u003eMetal Finishing and Plating Rinse Water\u003c\/td\u003e\u003c\/tr\u003e\n            \u003ctr\u003e\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e0e0e0;\"\u003eProcess Water and Chemical Dosing Systems\u003c\/td\u003e\u003c\/tr\u003e\n            \u003ctr style=\"background: #f9f9f9;\"\u003e\u003ctd style=\"padding: 10px;\"\u003eSurface Water Monitoring\u003c\/td\u003e\u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1 1 500px; min-width: 300px;\"\u003e\n      \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eEngineered for Harsh Process Conditions\u003c\/strong\u003e\u003c\/h4\u003e\n      \u003cul style=\"list-style-type: disc; padding-left: 20px; font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\n        \u003cli style=\"margin-bottom: 10px;\"\u003e\n\u003cstrong\u003ePVDF body\u003c\/strong\u003e stands up to solvents, bleach, UV exposure, and biological growth, and wipes clean easily.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eFlat sensing tip\u003c\/strong\u003e sheds deposits instead of collecting them, cutting down on cleaning between calibrations.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eBuilt-in temperature sensor\u003c\/strong\u003e compensates pH readings automatically as process temperature shifts.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eMatching pin\u003c\/strong\u003e guards against ground-loop interference from pumps and other equipment in the tank.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e3\/4\" NPT thread\u003c\/strong\u003e for in-line mounting, tank immersion, or a flow cell.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n    \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eChoosing Your Configuration\u003c\/strong\u003e\u003c\/h4\u003e\n    \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eGlass sensor type\u003c\/strong\u003e should match your process chemistry and temperature:\u003c\/p\u003e\n    \u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch; margin-bottom: 24px;\"\u003e\n      \u003ctable style=\"width: 100%; min-width: 520px; border-collapse: collapse; border: 1px solid #e0e0e0; font-size: 1rem;\"\u003e\n        \u003cthead\u003e\n          \u003ctr style=\"background: #f4f4f4;\"\u003e\n            \u003cth style=\"padding: 10px; text-align: left; font-weight: 600; border-bottom: 1px solid #e0e0e0;\"\u003eGlass\u003c\/th\u003e\n            \u003cth style=\"padding: 10px; text-align: left; font-weight: 600; border-bottom: 1px solid #e0e0e0;\"\u003epH Range\u003c\/th\u003e\n            \u003cth style=\"padding: 10px; text-align: left; font-weight: 600; border-bottom: 1px solid #e0e0e0;\"\u003eTemperature\u003c\/th\u003e\n            \u003cth style=\"padding: 10px; text-align: left; font-weight: 600; border-bottom: 1px solid #e0e0e0;\"\u003eBest For\u003c\/th\u003e\n          \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e0e0e0;\"\u003eLow Temperature (LT)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e0e0e0;\"\u003e0 to 12 pH\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e0e0e0;\"\u003e-5 to 80 °C\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e0e0e0;\"\u003eAmbient-temperature water and wastewater\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e0e0e0;\"\u003eHigh Temperature (HT)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e0e0e0;\"\u003e0 to 14 pH\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e0e0e0;\"\u003e0 to 100 °C\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #e0e0e0;\"\u003eHot processes and strongly alkaline solutions\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd style=\"padding: 10px;\"\u003eFluoride-resistant (HF)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e0 to 10 pH\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e-5 to 60 °C\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eSolutions containing fluoride or hydrofluoric acid\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eJunction:\u003c\/strong\u003e PTFE resists clogging and chemical attack, and is the better pick for dirty or aggressive process streams. Ceramic is the standard choice for cleaner water.\u003c\/p\u003e\n    \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eCable length:\u003c\/strong\u003e the 5, 10, 15, 25, and 50 m options include a patch cable that connects to the probe's DIN connector. Measure the routed path from the probe to the controller, not the straight-line distance. The DIN connector option ships without a cable, for installations that need a patch cable purchased separately.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"background: #f9f9f9; border: 1px solid #e0e0e0; border-radius: 8px; padding: 24px;\"\u003e\n    \u003ch4 style=\"font-size: 1rem; font-weight: 400; margin: 0 0 12px 0;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h4\u003e\n    \u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003eThis is a digital probe that communicates over RS-485. It works with the Hanna HI510 and HI520 process controllers and \u003cstrong\u003ewill not connect to BNC-input meters or controllers\u003c\/strong\u003e. For a BNC system, ask us about the analog versions of this probe.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n","brand":"Hanna Instruments","offers":[{"title":"Low Temperature (LT) glass \/ PTFE junction \/ Supplied with DIN Connector (without cable)","offer_id":52716943606058,"sku":"HI1006-1800","price":509.99,"currency_code":"USD","in_stock":true},{"title":"Low Temperature (LT) glass \/ PTFE junction \/ 5m (16.4')","offer_id":52716943638826,"sku":"HI1006-1805","price":579.99,"currency_code":"USD","in_stock":true},{"title":"Low Temperature (LT) glass \/ PTFE junction \/ 10m (32.8')","offer_id":52716943671594,"sku":"HI1006-1810","price":649.99,"currency_code":"USD","in_stock":true},{"title":"Low Temperature (LT) glass \/ PTFE junction \/ 15m (49.2')","offer_id":52716943704362,"sku":"HI1006-1815","price":789.99,"currency_code":"USD","in_stock":true},{"title":"Low Temperature (LT) glass \/ PTFE junction \/ 25m (82')","offer_id":52716943737130,"sku":"HI1006-1825","price":999.99,"currency_code":"USD","in_stock":true},{"title":"Low Temperature (LT) glass \/ PTFE junction \/ 50m (164')","offer_id":52716943769898,"sku":"HI1006-1850","price":1324.99,"currency_code":"USD","in_stock":true},{"title":"Low Temperature (LT) glass \/ Ceramic junction \/ Supplied with DIN Connector (without cable)","offer_id":52716943802666,"sku":"HI1016-1800","price":509.99,"currency_code":"USD","in_stock":true},{"title":"Low Temperature (LT) glass \/ Ceramic junction \/ 5m (16.4')","offer_id":52716943835434,"sku":"HI1016-1805","price":579.99,"currency_code":"USD","in_stock":true},{"title":"Low Temperature (LT) glass \/ Ceramic junction \/ 10m (32.8')","offer_id":52716943868202,"sku":"HI1016-1810","price":649.99,"currency_code":"USD","in_stock":true},{"title":"Low Temperature (LT) glass \/ Ceramic junction \/ 15m (49.2')","offer_id":52716943900970,"sku":"HI1016-1815","price":789.99,"currency_code":"USD","in_stock":true},{"title":"Low Temperature (LT) glass \/ Ceramic junction \/ 25m (82')","offer_id":52716943933738,"sku":"HI1016-1825","price":999.99,"currency_code":"USD","in_stock":true},{"title":"Low Temperature (LT) glass \/ Ceramic junction \/ 50m (164')","offer_id":52716943966506,"sku":"HI1016-1850","price":1324.99,"currency_code":"USD","in_stock":true},{"title":"High Temperature (HT) glass \/ PTFE junction \/ Supplied with DIN Connector (without cable)","offer_id":52716943999274,"sku":"HI1006-3800","price":509.99,"currency_code":"USD","in_stock":true},{"title":"High Temperature (HT) glass \/ PTFE junction \/ 5m (16.4')","offer_id":52716944032042,"sku":"HI1006-3805","price":579.99,"currency_code":"USD","in_stock":true},{"title":"High Temperature (HT) glass \/ PTFE junction \/ 10m (32.8')","offer_id":52716944064810,"sku":"HI1006-3810","price":649.99,"currency_code":"USD","in_stock":true},{"title":"High Temperature (HT) glass \/ PTFE junction \/ 15m (49.2')","offer_id":52716944097578,"sku":"HI1006-3815","price":789.99,"currency_code":"USD","in_stock":true},{"title":"High Temperature (HT) glass \/ PTFE junction \/ 25m (82')","offer_id":52716944130346,"sku":"HI1006-3825","price":999.99,"currency_code":"USD","in_stock":true},{"title":"High Temperature (HT) glass \/ PTFE junction \/ 50m (164')","offer_id":52716944163114,"sku":"HI1006-3850","price":1324.99,"currency_code":"USD","in_stock":true},{"title":"High Temperature (HT) glass \/ Ceramic junction \/ Supplied with DIN Connector (without cable)","offer_id":52716944195882,"sku":"HI1016-3800","price":509.99,"currency_code":"USD","in_stock":true},{"title":"High Temperature (HT) glass \/ Ceramic junction \/ 5m (16.4')","offer_id":52716944228650,"sku":"HI1016-3805","price":579.99,"currency_code":"USD","in_stock":true},{"title":"High Temperature (HT) glass \/ Ceramic junction \/ 10m (32.8')","offer_id":52716944261418,"sku":"HI1016-3810","price":649.99,"currency_code":"USD","in_stock":true},{"title":"High Temperature (HT) glass \/ Ceramic junction \/ 15m (49.2')","offer_id":52716944294186,"sku":"HI1016-3815","price":789.99,"currency_code":"USD","in_stock":true},{"title":"High Temperature (HT) glass \/ Ceramic junction \/ 25m (82')","offer_id":52716944326954,"sku":"HI1016-3825","price":999.99,"currency_code":"USD","in_stock":true},{"title":"High Temperature (HT) glass \/ Ceramic junction \/ 50m (164')","offer_id":52716944359722,"sku":"HI1016-3850","price":1324.99,"currency_code":"USD","in_stock":true},{"title":"Fluoride-resistant (HF) glass \/ PTFE junction \/ Supplied with DIN Connector (without cable)","offer_id":52716944392490,"sku":"HI1006-4800","price":509.99,"currency_code":"USD","in_stock":true},{"title":"Fluoride-resistant (HF) glass \/ PTFE junction \/ 5m (16.4')","offer_id":52716944425258,"sku":"HI1006-4805","price":579.99,"currency_code":"USD","in_stock":true},{"title":"Fluoride-resistant (HF) glass \/ PTFE junction \/ 10m (32.8')","offer_id":52716944458026,"sku":"HI1006-4810","price":649.99,"currency_code":"USD","in_stock":true},{"title":"Fluoride-resistant (HF) glass \/ PTFE junction \/ 15m (49.2')","offer_id":52716944490794,"sku":"HI1006-4815","price":789.99,"currency_code":"USD","in_stock":true},{"title":"Fluoride-resistant (HF) glass \/ PTFE junction \/ 25m (82')","offer_id":52716944523562,"sku":"HI1006-4825","price":999.99,"currency_code":"USD","in_stock":true},{"title":"Fluoride-resistant (HF) glass \/ PTFE junction \/ 50m (164')","offer_id":52716944556330,"sku":"HI1006-4850","price":1324.99,"currency_code":"USD","in_stock":true},{"title":"Fluoride-resistant (HF) glass \/ Ceramic junction \/ Supplied with DIN Connector (without cable)","offer_id":52716944589098,"sku":"HI1016-4800","price":509.99,"currency_code":"USD","in_stock":true},{"title":"Fluoride-resistant (HF) glass \/ Ceramic junction \/ 5m (16.4')","offer_id":52716944621866,"sku":"HI1016-4805","price":579.99,"currency_code":"USD","in_stock":true},{"title":"Fluoride-resistant (HF) glass \/ Ceramic junction \/ 10m (32.8')","offer_id":52716944654634,"sku":"HI1016-4810","price":649.99,"currency_code":"USD","in_stock":true},{"title":"Fluoride-resistant (HF) glass \/ Ceramic junction \/ 15m (49.2')","offer_id":52716944687402,"sku":"HI1016-4815","price":789.99,"currency_code":"USD","in_stock":true},{"title":"Fluoride-resistant (HF) glass \/ Ceramic junction \/ 25m (82')","offer_id":52716944720170,"sku":"HI1016-4825","price":999.99,"currency_code":"USD","in_stock":true},{"title":"Fluoride-resistant (HF) glass \/ Ceramic junction \/ 50m (164')","offer_id":52716944752938,"sku":"HI1016-4850","price":1324.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/HI1006-1805_standing_480x720__22150.1677773979.webp?v=1790005494"}],"url":"https:\/\/bluetigerscientific.com\/collections\/hanna-instruments-probes-electrodes.oembed","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}