{"title":"Dissolved Oxygen Calibration \u0026 Maintenance","description":null,"products":[{"product_id":"milwaukee-ma9072s-oxygen-electrolyte-solution","title":"Milwaukee MA9072S Oxygen Electrolyte Solution","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; padding: 40px 20px; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333; background: #fff; font-size: 0.95rem; box-sizing: border-box;\"\u003e\n  \u003cdiv style=\"display: flex; flex-direction: column; gap: 20px;\"\u003e\n    \u003cdiv class=\"productView-desc-content\" itemprop=\"description\"\u003e\n      \u003ch2\u003eDescription\u003c\/h2\u003e\n      \u003cp\u003eThe Milwaukee MA9072S Oxygen Electrolyte Solution is specifically formulated for optimal performance with the Milwaukee MA860 Galvanic Dissolved Oxygen probe and MA861 Dissolved Oxygen membranes. This high-quality electrolytic solution plays a crucial role in maintaining the accuracy and reliability of your dissolved oxygen measurements, ensuring you receive precise data for your applications.\u003c\/p\u003e\n      \u003ch2\u003eKey Features\u003c\/h2\u003e\n      \u003cp\u003eThis premium formulation is produced under stringent quality controls using reagent-grade chemicals in a temperature-controlled environment, guaranteeing consistent results.\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePrecise formulation:\u003c\/strong\u003e Factory mixed for optimal performance with Milwaukee probes.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eTraceability:\u003c\/strong\u003e Each product is labeled with a product code, lot number, and expiration date for easy tracking.\u003c\/li\u003e\n      \u003c\/ul\u003e\n      \u003cp\u003eThe MA9072S solution comes in a secure, air-tight bottle with a tamper-proof seal that ensures freshness and integrity. Its design includes an easy drop tip for precise volume control, making it a user-friendly choice for professionals in various fields.\u003c\/p\u003e\n      \u003cp\u003eFor optimal accuracy, always use fresh MA9072S electrolyte solution and regularly check your membranes for any signs of damage, such as wrinkles or stretch marks. These tips help maintain the longevity and performance of your dissolved oxygen probes.\u003c\/p\u003e\n      \u003cp\u003eThank you for choosing Milwaukee products. We are dedicated to helping you elevate your measurement results and achieve greater accuracy in your work.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Milwaukee Instruments","offers":[{"title":"Default Title","offer_id":50549135868202,"sku":"BTS-MA9072S","price":28.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/MA9072S__81037.1618410218.jpg?v=1756585970"},{"product_id":"milwaukee-ma9071-oxygen-electrolyte-solution","title":"Milwaukee MA9071 Oxygen Electrolyte Solution","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; padding: 40px 20px;\n                        font-family: 'Open Sans', sans-serif; font-weight: 300;\n                        color: #333; background: #fff; font-size: 0.95rem;\n                        box-sizing: border-box;\"\u003e\n              \u003cdiv style=\"display: flex; flex-direction: column; gap: 20px;\"\u003e\n                \u003cdiv class=\"productView-desc-content\" itemprop=\"description\"\u003e\n\n                \u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe MA9071 electrolyte fill solution is designed for Milwaukee's polarographic dissolved oxygen probe. A high quality electrolyte solution is crucial to the performance of your dissolved oxygen probe.\u003c\/p\u003e\n\u003ch2\u003eDesign Features\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003ePrecise formulation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFactory mixed using reagent grade chemicals in a dedicated, temperature controlled environment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTraceable\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eProduct labeled with product code, lot number and expiration date.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSecure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAir tight bottle with tamper-proof seal.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eUse and Care\u003c\/h2\u003e\n\u003ch3\u003e“Open Air” Calibration Procedure for the MW600 Dissolved Oxygen Meter\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Remove the membrane\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTake the membrane off the end of the probe and dry the diode off.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Zero out the display\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screw driver provided and through the access hole make the unit display read 0.0.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Fill the membrane\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGo to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Attach the membrane\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eScrew the membrane on to the probe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Let stablize\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTurn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Adjust\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePush down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eYou are now calibrated.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eExtra tips\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWatch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane.\u003c\/li\u003e\n\u003cli\u003eAlways use fresh electrolyte solution (MA9071).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWatch this video to learn more about the Open Air Calibration method.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/qGTcfxPbFgs\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThank you for considering Milwaukee to help you take your results to the next level.\u003c\/p\u003e\n\n                \u003c!-- snippet location product_description --\u003e\n\n            \u003c\/div\u003e\n              \u003c\/div\u003e\n            \u003c\/div\u003e","brand":"Milwaukee Instruments","offers":[{"title":"Default Title","offer_id":50549135900970,"sku":"BTS-MA9071","price":48.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/MA9071__41066.1609437922.jpg?v=1756585971"},{"product_id":"milwaukee-ma9070-zero-oxygen-calibration-solution-kit","title":"Milwaukee MA9070 Zero Oxygen Calibration Solution Kit","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; padding: 40px 20px;\n                        font-family: 'Open Sans', sans-serif; font-weight: 300;\n                        color: #333; background: #fff; font-size: 0.95rem;\n                        box-sizing: border-box;\"\u003e\n  \u003ch2\u003eOverview\u003c\/h2\u003e\n  \u003cp\u003eThe Milwaukee MA9070 Zero Oxygen Calibration Solution Kit is essential for achieving accurate readings with the Milwaukee MW600 DO Meter. This kit is specifically designed to provide a reliable and straightforward method for calibrating to 0% oxygen concentration.\u003c\/p\u003e\n  \u003ch2\u003eKey Features\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cb\u003eEasy Calibration:\u003c\/b\u003e Simply combine the two solution components to create a precise environment for calibration. This user-friendly approach saves you time and ensures your measurements are accurate.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cb\u003eTraceable Quality:\u003c\/b\u003e Each kit is labeled with a unique product code, lot number, and expiration date. This traceability guarantees the integrity and reliability of your calibration process.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cb\u003eSecure Packaging:\u003c\/b\u003e The solution comes in an air-tight bottle equipped with a tamper-proof seal, ensuring that the solution remains uncontaminated until you are ready to use it.\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003ch2\u003eApplication\u003c\/h2\u003e\n  \u003cp\u003eThis calibration solution is ideal for professionals in environmental monitoring, aquaculture, and various scientific laboratories. Regular calibration using the MA9070 ensures that your DO Meter provides the most accurate and reliable readings, which are vital for maintaining optimal conditions in your projects.\u003c\/p\u003e\n  \u003ch2\u003eOrdering Information\u003c\/h2\u003e\n  \u003cp\u003eInvesting in the Milwaukee MA9070 Zero Oxygen Calibration Solution Kit is a smart choice for anyone who values precision in measurement. Ensure your Milwaukee MW600 DO Meter operates at peak performance by using this specialized calibration solution. Designed for convenience and reliability, this kit is a must-have for your lab or field application.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Milwaukee Instruments","offers":[{"title":"Default Title","offer_id":50549136228650,"sku":"BTS-MA9070","price":21.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/MA9070__25215.1609801887.jpg?v=1756585972"}],"url":"https:\/\/bluetigerscientific.com\/collections\/dissolved-oxygen-calibration-maintenance.oembed","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}