{"title":"Cell Strainers","description":null,"products":[{"product_id":"mtc-bio-surestrain-premium-cell-strainers","title":"MTC Bio SureStrain™ Premium Cell Strainers – 5 to 100 µm","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333; background: #fff;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: min(300px, 100%); text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BTS-surestrain-1.jpg?v=1790635729\" alt=\"MTC Bio SureStrain™ Premium Cell Strainers – 5 to 100 µm\" style=\"width: 100%; max-width: 440px; height: auto; object-fit: contain; border-radius: 8px;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: min(300px, 100%);\"\u003e\n\u003ch3 style=\"font-size: 1.15rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eControl Your Cell-Straining Workflow\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003eA choice of eight color-coded nylon mesh sizes helps you match cell and tissue preparations to your protocol. SureStrain combines a polypropylene frame with an aerated design that allows air to escape as filtrate enters the receiving tube.\u003c\/p\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003eEach pack contains 50 sterile, individually blister-packed strainers and one reducing adapter. Tubes, plates and pestles shown in application imagery are not included.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 16px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003e5–100 µm\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003eEight mesh sizes\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003e50\/pack\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003eIndividually wrapped\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003eNylon\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003eMesh material\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003e1 adapter\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003eIncluded per pack\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eDesigned for Your Bench\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 28px 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eAerated frame\u003c\/strong\u003e\u003cbr\u003eDesigned to reduce air-lock effects during filtration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eColor-coded selection\u003c\/strong\u003e\u003cbr\u003eIdentify your chosen mesh size at a glance.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eFlexible collection\u003c\/strong\u003e\u003cbr\u003eDesigned for 50 mL tubes; an included adapter supports smaller tube formats.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003ePlate workflows\u003c\/strong\u003e\u003cbr\u003eCompatible with 6-well plates; 1.5 mm feet support straining into flat plates and dishes.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 400px; min-width: min(280px, 100%); text-align: center; order: 1;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BTS-surestrain-2.jpg?v=1790635729\" alt=\"MTC Bio SureStrain™ Premium Cell Strainers – 5 to 100 µm detail\" style=\"width: 100%; max-width: 420px; height: auto; object-fit: contain; border-radius: 8px;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: min(300px, 100%); order: 2;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eChoose the Format for Your Protocol\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003eSelect mesh size by your sample and validated protocol, not color alone. Confirm receiving-vessel fit before processing valuable samples. One unit ordered is a pack of 50 strainers; the reducing adapter is supplied one per pack.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eAt a Glance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; min-width: min(240px, 100%); border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1rem; margin: 0 0 12px 0;\"\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eFrame \/ mesh:\u003c\/strong\u003e Polypropylene \/ nylon\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 240px; min-width: min(240px, 100%); border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1rem; margin: 0 0 12px 0;\"\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eSterility:\u003c\/strong\u003e Sterile, individually blister packed\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 240px; min-width: min(240px, 100%); border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1rem; margin: 0 0 12px 0;\"\u003e\u003cstrong\u003eHandling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eSupplier purity claims:\u003c\/strong\u003e RNase, DNase, pyrogen and cytotoxin free\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul style=\"margin: 0; padding-left: 20px; columns: 2 260px;\"\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003ePreparing dissociated cell samples for flow cytometry\u003c\/li\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eRemoving aggregates from cell suspensions\u003c\/li\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eProtocol-specific tissue preparation\u003c\/li\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eStraining into suitable tubes, plates or dishes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eSureStrain — Manufacturer Demonstration\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv style=\"position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 860px; margin: 0 auto; border-radius: 8px;\"\u003e\u003ciframe style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%; border: 0; border-radius: 8px;\" src=\"https:\/\/www.youtube.com\/embed\/EhuEazBVxQA\" title=\"SureStrain — Manufacturer Demonstration\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f9f9f9; border: 1px solid #e0e0e0; border-radius: 8px; padding: 24px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eOrdering and Application Tip\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003eSelect mesh size by your sample and validated protocol, not color alone. Confirm receiving-vessel fit before processing valuable samples. One unit ordered is a pack of 50 strainers; the reducing adapter is supplied one per pack.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-top: 1px solid #e0e0e0; margin-top: 40px; padding-top: 20px;\"\u003e\u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;\"\u003e\n\u003ch3 style=\"font-size: 1.1rem; font-weight: 600; margin: 0 0 16px 0;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich SureStrain models are 40, 70 and 100 micron cell strainers?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eC4040 is the blue 40 µm cell strainer, C4070 is the white 70 µm strainer, and C4100 is the yellow 100 µm strainer. SureStrain also offers 5, 10, 20, 30 and 50 µm meshes. Choose the catalog number and mesh size required by your protocol, not color alone.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat is included in one pack?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eEach ordering unit contains 50 individually wrapped sterile strainers and one reducing adapter. It does not contain 50 adapters, receiving tubes or a pestle.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat are the strainer materials?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe frame is polypropylene and the mesh is nylon. MTC Bio identifies these strainers as RNase, DNase, pyrogen and cytotoxin free.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDo SureStrain cell strainers fit 50 mL tubes or smaller collection tubes?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eSureStrain cell strainers are designed for 50 mL tubes and are compatible with 6-well plates. Each pack of 50 sterile strainers includes one reducing adapter for smaller collection tube formats, such as 15 mL and 5 mL tubes. Confirm fit and dimensions for your specific receiving vessel; the pack does not include 50 adapters.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhy does the frame include feet and aeration?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe aerated design provides a path for air to escape while filtrate enters the tube. The 1.5 mm feet support use over flat plates and dishes.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eCan strainers be stacked?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eYes. MTC Bio describes the frames as interlocking and stackable. Validate any sequential-filtration arrangement for recovery and sample suitability.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow does the 40 µm option compare with Falcon 352340?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eSureStrain C4040 and Corning Falcon 352340 both use 40 µm nylon mesh with a polypropylene frame and sterile individual packaging, supplied 50 per ordering unit. SureStrain includes one reducing adapter per pack; Corning describes 352340 as fitting 50 mL Falcon conical tubes. These are separately manufactured products, not certified identical or guaranteed interchangeable. Validate fit and recovery before changing your workflow.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWill straining guarantee a single-cell suspension?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. Mesh size is only one part of sample preparation. Cell size, tissue dissociation, aggregate loading and protocol all affect recovery and downstream results.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003eThird-party brands are trademarks of their respective owners. Blue Tiger Scientific is not affiliated with those manufacturers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003csection data-internal-links=\"review45\" style=\"margin:28px 0;padding:20px;border:1px solid #dbe4ec;border-radius:10px;\"\u003e\u003ch2 style=\"margin-top:0;\"\u003eRelated products and workflow options\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003eAlternative format:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/mtc-bio-readystrain-cell-straining-kits\"\u003eReadyStrain preassembled cell-straining kits\u003c\/a\u003e — An alternative when a strainer, collection tube and cap in one sterile packet are preferred.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/mtc-bio-flowtubes-flow-cytometry-tubes\"\u003eFlowTubes flow-cytometry tubes\u003c\/a\u003e — For downstream flow-cytometry sample handling; a separate tube format, not a claim of direct strainer fit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e","brand":"MTC Bio","offers":[{"title":"5 µm | Orange | 50\/pack","offer_id":52789381366058,"sku":"BTS-C7005","price":127.66,"currency_code":"USD","in_stock":true},{"title":"10 µm | Teal | 50\/pack","offer_id":52789381398826,"sku":"BTS-C7010","price":127.66,"currency_code":"USD","in_stock":true},{"title":"20 µm | Red | 50\/pack","offer_id":52789381431594,"sku":"BTS-C7020","price":127.66,"currency_code":"USD","in_stock":true},{"title":"30 µm | Purple | 50\/pack","offer_id":52789381464362,"sku":"BTS-C7030","price":127.66,"currency_code":"USD","in_stock":true},{"title":"40 µm | Blue | 50\/pack","offer_id":52789381497130,"sku":"BTS-C4040","price":127.66,"currency_code":"USD","in_stock":true},{"title":"50 µm | Grey | 50\/pack","offer_id":52789381529898,"sku":"BTS-C7050","price":127.66,"currency_code":"USD","in_stock":true},{"title":"70 µm | White | 50\/pack","offer_id":52789381562666,"sku":"BTS-C4070","price":127.66,"currency_code":"USD","in_stock":true},{"title":"100 µm | Yellow | 50\/pack","offer_id":52789381595434,"sku":"BTS-C4100","price":127.66,"currency_code":"USD","in_stock":true},{"title":"Adapter only | 15 mL \/ 5 mL reducing adapter | Sterile | 25\/pack","offer_id":52804437967146,"sku":"BTS-C4015","price":56.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BTS-surestrain-1.jpg?v=1790635729"},{"product_id":"mtc-bio-readystrain-cell-straining-kits","title":"MTC Bio ReadyStrain™ Cell Straining Kits – 40, 70 \u0026 100 µm","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333; background: #fff;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: min(300px, 100%); text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BTS-readystrain-1.jpg?v=1790635748\" alt=\"MTC Bio ReadyStrain™ Cell Straining Kits – 40, 70 \u0026amp; 100 µm\" style=\"width: 100%; max-width: 440px; height: auto; object-fit: contain; border-radius: 8px;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: min(300px, 100%);\"\u003e\n\u003ch3 style=\"font-size: 1.15rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eOpen One Packet. Start Straining.\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003eReadyStrain brings a SureStrain cell strainer, 50 mL collection tube and separate screw cap together in one sterile packet. The strainer is pre-attached to the tube, reducing the number of packages and assembly steps at the bench.\u003c\/p\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003eSelect 40, 70 or 100 µm mesh to suit your protocol. Easy-open tear-strip bags let you open a single kit directly in your controlled work area without exposing a bulk bag of tubes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 16px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003e3 sizes\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003e40, 70 or 100 µm\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003e50 mL\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003eIncluded tube\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003e50 kits\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003ePer pack\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003eSterile\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003eIndividual packets\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eDesigned for Your Bench\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 28px 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003ePreassembled workflow\u003c\/strong\u003e\u003cbr\u003eStrainer arrives attached to its collection tube.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eCap included\u003c\/strong\u003e\u003cbr\u003eA separate screw cap supports handling after filtration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eEasy-open packaging\u003c\/strong\u003e\u003cbr\u003eTear-strip packets reduce separate package handling.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eGamma sterilized\u003c\/strong\u003e\u003cbr\u003eManufacturer specifies a sterility assurance level of 10⁻⁶.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 400px; min-width: min(280px, 100%); text-align: center; order: 1;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BTS-readystrain-2.jpg?v=1790635748\" alt=\"MTC Bio ReadyStrain™ Cell Straining Kits – 40, 70 \u0026amp; 100 µm detail\" style=\"width: 100%; max-width: 420px; height: auto; object-fit: contain; border-radius: 8px;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: min(300px, 100%); order: 2;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eChoose the Format for Your Protocol\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003eOne unit ordered supplies 50 complete kits, not 50 separate strainers. Choose mesh size for your protocol. A sterile packet supports aseptic handling but does not eliminate contamination risk once opened.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eAt a Glance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; min-width: min(240px, 100%); border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1rem; margin: 0 0 12px 0;\"\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eMesh choices:\u003c\/strong\u003e 40 µm blue; 70 µm white; 100 µm yellow\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 240px; min-width: min(240px, 100%); border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1rem; margin: 0 0 12px 0;\"\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eKit contents:\u003c\/strong\u003e SureStrain strainer, 50 mL tube and separate screw cap\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 240px; min-width: min(240px, 100%); border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1rem; margin: 0 0 12px 0;\"\u003e\u003cstrong\u003eHandling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eSterilization:\u003c\/strong\u003e Gamma; manufacturer-stated SAL 10⁻⁶\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul style=\"margin: 0; padding-left: 20px; columns: 2 260px;\"\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eCell-suspension preparation\u003c\/li\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eCollecting filtered tissue preparations\u003c\/li\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eFlow cytometry sample preparation\u003c\/li\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eSingle-kit use in controlled work areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f9f9f9; border: 1px solid #e0e0e0; border-radius: 8px; padding: 24px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eOrdering and Application Tip\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003eOne unit ordered supplies 50 complete kits, not 50 separate strainers. Choose mesh size for your protocol. A sterile packet supports aseptic handling but does not eliminate contamination risk once opened.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-top: 1px solid #e0e0e0; margin-top: 40px; padding-top: 20px;\"\u003e\u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;\"\u003e\n\u003ch3 style=\"font-size: 1.1rem; font-weight: 600; margin: 0 0 16px 0;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat is supplied in each kit?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eEach sterile kit includes a SureStrain cell strainer pre-attached to a 50 mL tube, plus a separate screw cap for use after filtration.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich pore sizes are offered?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eC5040 is 40 µm blue, C5070 is 70 µm white and C5100 is 100 µm yellow.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow many kits are in one ordering unit?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eOne pack contains 50 individually wrapped complete kits. Inventory and pricing are per pack, not per single kit.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow are the kits sterilized?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eMTC Bio states that ReadyStrain kits are gamma sterilized to a sterility assurance level of 10⁻⁶. Maintain appropriate aseptic handling after opening.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat is the benefit of the single packet?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eIt reduces the need to open and assemble separate strainer, tube and cap packages. You can open one tear-strip packet rather than exposing a larger bag of tubes.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs the screw cap attached during straining?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. The strainer is pre-attached to the tube; the screw cap is separate and is used after filtration.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow does ReadyStrain compare with buying Falcon 352340 strainers?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eCorning Falcon 352340 is a sterile 40 µm nylon cell strainer, individually packaged, 50 per case, designed to fit 50 mL Falcon conical tubes. ReadyStrain C5040 instead supplies 50 complete 40 µm kits with a tube and separate screw cap in each packet. These are different ordering configurations, not claims of identical performance or universal interchangeability.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes the kit guarantee a single-cell preparation?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. Select and validate mesh size, dissociation conditions and sample handling for your cells and downstream assay. A kit simplifies assembly, not biological validation.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003eThird-party brands are trademarks of their respective owners. Blue Tiger Scientific is not affiliated with those manufacturers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003csection data-internal-links=\"review45\" style=\"margin:28px 0;padding:20px;border:1px solid #dbe4ec;border-radius:10px;\"\u003e\u003ch2 style=\"margin-top:0;\"\u003eRelated products and workflow options\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003eAlternative format:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/mtc-bio-surestrain-premium-cell-strainers\"\u003eSureStrain standalone cell strainers\u003c\/a\u003e — Compare additional mesh sizes when a preassembled 40, 70 or 100 µm kit is not the right format.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:12px;\"\u003e\n\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/mtc-bio-flowtubes-flow-cytometry-tubes\"\u003eFlowTubes flow-cytometry tubes\u003c\/a\u003e — For downstream sample handling after cell preparation; not interchangeable collection tubes for this kit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e","brand":"MTC Bio","offers":[{"title":"40 µm | Blue | 50 kits\/pack","offer_id":52789384970538,"sku":"BTS-C5040","price":195.36,"currency_code":"USD","in_stock":true},{"title":"70 µm | White | 50 kits\/pack","offer_id":52789385003306,"sku":"BTS-C5070","price":195.36,"currency_code":"USD","in_stock":true},{"title":"100 µm | Yellow | 50 kits\/pack","offer_id":52789385036074,"sku":"BTS-C5100","price":195.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BTS-readystrain-1.jpg?v=1790635748"}],"url":"https:\/\/bluetigerscientific.com\/collections\/cell-strainers.oembed","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}